As the yokes _F F_ and the conduit casing _j_ are made of iron and

are in metallic connection with the track rails, it is evident that

if the conduits should fill with water to the depth of the wire _f_

the current would pass directly to the rails, and thus would avoid the

longer path through the motors. To prevent this occurrence, the sides

of the conduit are inclosed with the sheet-iron covers _c c_, which

nominally are in the position shown by the dotted lines _i i_. The

plow is also provided with the arms _b b_, upon the ends of which are

mounted small wheels _a a_, and these run upon tracks attached to the

covers _c c_. As is shown in the figure, the wheels _a a_, running upon

the tracks attached to the covers _c c_, cause the latter to spread

out to the position in which they are shown. This spreading, as can be

readily understood, only takes place for a short distance ahead and

behind the plow, but at all other parts of the conduit the sides assume

the position _i i_, and thus close the conduit and exclude the water.

It can be easily seen that some difficulty would be encountered in

making a tight joint at _h h_, and also that the opening and closing of

the sides might not operate as perfectly in practice as upon paper, but

it does not follow from these facts that the design is not practical;

it simply illustrates that there are many minor difficulties to be

overcome in order that complete success may be attained. Many designs

operating upon this principle have been patented, and in some of them a

great amount of ingenuity is displayed.

[Illustration: FIG. 26.--UNDERGROUND CONDUIT WITH INCLOSED CONDUCTOR.]

Fig. 26 illustrates another type of inclosed conductor which at a first

glance appears to be far superior to that just described, but upon

closer investigation it is found to be not wholly free from objections

that are difficult to overcome. The yoke _F F_, as in the design just

described, is made wide enough to support upon its outer ends the track

rails _R R_, and is cut away in the middle to an outline conforming

with the shape of the conduit. The conductor that carries the current

is located at _d_, being supported by the stands _e_. An elastic tube

_f_ is provided, which is water-tight and thus excludes moisture from

its interior, within which the conductor _d_ is located. On the top of

tube _f_ a flexible rail _b_ is secured, and this connects with studs

_c_, which are within the tube, as clearly shown in the drawing, and so

situated that they may be forced down into contact with _d_. Normally

these studs are separated from _d_, but when the car comes along, the

wheel _a_, mounted upon the end of plow _P_, flattens the tube _f_ and

thus forces one or more of the studs _c_ into contact with _d_. The

distance between the studs _c_ is such that at least two will always be

in contact with _d_, thus insuring a continuous electrical connection

with the motors so long as the plow is depressed.

The first impression upon looking at this design would be that it is

entirely free from objections; for if we assume that the tube _f_ is

made of rubber, we can see it in our mind's eye springing up after

the plow passes by and thus separating the contacts _c_ from _d_, and

at the same time yielding freely to the pressure of the wheel _a_.

All of this is true, but rubber is not very durable when under such

exposed conditions, and to maintain a length of several miles of it in

a perfect state for even two or three years could not reasonably be

expected; and if it became necessary to renew the tube oftener than

this the cost of maintenance would be entirely too great. There is

another objection, however, which is more serious, and that is that the

conduit will gradually fill up with dirt, and this pressing against the

rubber tube would force it out of shape, and thus cause the contacts

_c_ to bear permanently upon _d_, or else to become so far displaced

that they would not touch it when depressed by the plow.

As the rubber tube can not be depended upon, inventors have sought

to improve the construction by using sheet steel and making the

tube flatter and much wider, so that a section of it would present

an outline much resembling an elliptic carriage spring. Such a

construction will meet the requirements as to strength and the

retention of the contacts _c_ in their proper position; but steel

expands when warm and contracts when cooled, therefore a long tube

would be stretched so much in winter that it might pull apart, while in

summer it would be compressed and tend to buckle up and thus be forced

out of place. These difficulties can be overcome by providing expansion

joints at suitable intervals, so that they are not necessarily proof

of the impracticability of devices based upon the principles involved

in this design; they simply serve to forcibly bring to mind the fact

that the path of the inventor of underground systems is not strewn with

roses, no matter in what direction he may turn to find a solution of

the problem.

[Illustration: FIG. 27.--UNDERGROUND CONDUIT WITH EXPOSED CONDUCTORS.]

The object in the designs Figs. 25 and 26 is to shield the conductor

so that it will remain dry should the conduit be filled or partially

filled with water. If water could be excluded from the conduit, the

casing _j c c_, in the first figure, and the tube _f_, in the second

one, would not be required, for there is no difficulty in providing an

insulating support that will hold the conductor firmly in place and

at the same time prevent the escape of the current; but as soon as

moisture collects upon the surfaces of the insulating supports it acts

as a conductor, and thus renders the insulation of little value. If

water runs into the conduit in such quantities as to come in contact

with the conductor, then the effect of the insulation is entirely

destroyed; the aim of the inventors, therefore, is to provide means for

preventing the accumulation of water or moisture around the conducting

wire. It can be readily seen that the shorter the conductor the easier

it is to protect it, and this fact has given rise to the development of

a great number of designs classified as sectional conductors. In these,

two conductors are used, one of which is continuous and so situated

and insulated that it can not under any conditions be reached by either

moisture or water. The other conductor is made in lengths that vary

all the way from fifteen to two or three hundred feet. Normally, these

short sections are not connected with the circuit--they are dead, as

it is called--but when the car comes along, the plow, by acting upon

suitable mechanism, establishes a connection between the continuous

conductor and the portion of the sectional conductor that is directly

under it, and in this way the current passes to the car. As soon

as the car passes beyond a section of the sectional conductor, the

connection between it and the continuous wire is broken automatically.

Some of these arrangements depend upon mechanical devices, such as

levers that are struck by the plow and thereby move a switch that

closes a connection between the section and the continuous conductor,

but in most instances the switch is operated by a magnet, which may

be carried by the car or may be arranged so as to be energized as the

car approaches it. Designs of this last type come under the head of

electrically operated sectional conductor systems. There are other

arrangements in which a magnet carried by the car attracts iron levers

suitably disposed along the conduit, and these levers close switches

that connect the section of conductor under the car with the continuous

one. As the levers are actuated by the magnet, they only hold the

switch closed while the latter passes over them; thus the electrical

connection is made and broken as the car moves along.

[Illustration: FIG. 28.--VIEW OF STREET RAILWAY LINES IN WASHINGTON

OPERATED BY UNDERGROUND CONDUCTOR OF TYPE SHOWN IN FIG. 27.]

Most of the designs in which sectional conductors are used can be

placed much nearer to the surface of the street than the types

illustrated in Figs. 25 and 26, and this is a decided advantage, as it

greatly reduces the cost of construction. Any system that requires an

underground conduit, with the yokes _F F_ to support the track, can

only be used by roads upon which the traffic is very great, for the

cost of construction would be such as to prohibit its use under any

other conditions, no matter how successful its operation might be. For

small roads with moderate traffic the question of first cost is of

paramount importance, and the only system that can offer a satisfactory

solution of the problem for these is one that does not require an

underground conduit.

[Illustration: FIG. 29.--CROSS-SECTION OF RAILWAY TRACK PROVIDED WITH

THIRD-RAIL CONDUCTOR.]

Although many patents have been taken out for systems similar to

those described in the foregoing, nothing has been done practically

with any of them except in an experimental way. Some are in operation

on small roads in out-of-the-way places, being intended principally

to illustrate the practicability of the system and thus assist in

promoting its introduction elsewhere, but the system that has been

adopted in a commercial way is one in which no attempt is made to

shield the conductor from moisture and water, and for its successful

operation dependence is placed entirely upon the proper drainage of

the conduit. This system is well illustrated in Fig. 27. The plow _P_

carries upon its end two brushes, _b b_, which are insulated from each

other. These brushes rub against the conductors _a a_, which are made

of bars of channel iron and are well insulated from the yokes _F F_ and

the conduit casing to which they are attached by means of the supports

_c c_. In the construction shown in the figure the current comes

from the generator through one of the _a_ bars and returns through

the other, but both bars can be used to conduct the current from the

generator, in which case the return can be effected through the track

rails, just as in the designs already considered. If both the bars _a

a_ are used to convey the current from the power house the insulation

between the brushes _b b_ is not required. To avoid the accumulation

of water in the conduit the drain _G_ is provided with outlets _d_,

located at suitable points.

Although this system is the simplest that can be devised for use in

streets or public highways its construction is very costly, so much so

that it can only be used in cities where the traffic is so great as to

require the running of cars on short headway; and, furthermore, it can

not be operated with any degree of success except in municipalities

where there is a good sewage system. During the summer months it is

liable to be more or less impaired by heavy showers, but the trouble in

such cases is only temporary. In winter time snowstorms are liable to

affect it in the same way, especially if, after a heavy fall, a warm

wave comes along and produces a rapid thaw.

From the fact that no attempt whatever is made to protect the

conductors, one would naturally suppose that every time there is a rain

the road would be compelled to shut down; for, as the slot through

which the plow travels is open, water can enter the conduit with the

greatest freedom, and, in trickling down the sides, would be caught

to some extent upon the brackets _c c_, and thus make its way over to

the channel bars _a a_, and thereby destroy the insulation. Practice,

however, shows that this action does not take place, at least not so

often as to produce any serious trouble. The roads that are operated

by electricity in New York, and also the lines of the Capital Traction

Company, of Washington, D. C., employ this system, and they have been

in operation a sufficient length of time to fully demonstrate that

the difficulties actually developed by the action of the elements are

not of a formidable character. On one occasion the Sixth Avenue road,

in New York, was compelled to stop its cars for a short time just

after a severe snowstorm, but the failure was not due to impairment of

the insulation, according to the statements of the officials of the

company, but to the fact that the melted snow froze upon the track and

caused the wheels to slip around without sending the car ahead. The

fact that other roads in New York, belonging to the same company, are

being equipped with the system, is proof that, upon the whole, its

practical operation is regarded as satisfactory; but it is very evident

that it is not the final solution of the problem. A system to be a

decided success must cost very little more than the ordinary overhead

trolley, and its construction must be such that it will not easily get

out of order. If it is not inexpensive it will not come into use except

in places where the authorities will not permit the overhead wires.

A surface or underground system ought to be more durable than the

overhead, as the wires are not liable to be injured by high winds or

the accumulation of ice and snow; and, furthermore, as the conductors

are below the ground the danger of burning out motors and generators

by lightning would be eliminated, and this is a serious matter with

all trolley roads, especially in cities. Country roads do not suffer

so much from lightning, because when there is a heavy thunderstorm

the generators are stopped and the trolley poles are pulled away from

the wire, the cars remaining stalled on the track until the storm

passes over. This course can not be pursued by city roads, for the

passengers feel that, lightning or no lightning, they must reach their

destination, therefore the cars must continue to run and take their

chances. Lightning, however, does not strike trolley lines as often in

cities as in the open country, owing to the fact that there are so many

iron buildings and roofs to attract it in other directions.

[Illustration: FIG. 30.--VIEW OF A SECTION OF THE NEW YORK, NEW HAVEN

AND HARTFORD RAILROAD, EQUIPPED WITH THE THIRD-RAIL SYSTEM.]

Fig. 28 shows the appearance of the street surface when an underground

system such as is illustrated in Fig. 27 is used. This figure is a

photograph of the Capital Traction Company's lines in Washington.

After looking at this picture one can not deny that the appearance

of the streets of a city is greatly improved when the overhead wires

are removed, but underground systems which require a plow to run in a

groove are not without objection, for the groove forms a dangerous trap

into which the narrow-tired wheels of light wagons can readily drop,

and the toes and heels of horseshoes can be caught. Thus, unless the

slot can be dispensed with the greater beauty overhead is obtained at

the expense of increased danger on the street surface. There are quite

a number of underground conductor systems in which the slot is not

used, the current being conveyed to the car by contact made with plates

set at suitable intervals between or along the sides of the tracks, and

on a level with the street surface. Many of these arrangements appear

to be quite practical, but none of them can attract the attention of

railroad managers unless it can be constructed at a reasonable cost.

[Illustration: FIG. 31.--CROSS-SECTION OF RAILWAY TRACK, SHOWING A

MODIFICATION OF THE THIRD-RAIL SYSTEM.]

About two years ago the New York, New Haven, and Hartford Railroad

published a report of the performance of a branch line that was

equipped with electric motors, the current being conveyed to them by

means of a third rail. Some of the sensational dailies at once took

the matter up and heralded the third rail to the public as something

entirely new and sure to supersede the trolley. Now, as a matter of

fact, the third rail is one of the oldest arrangements that have been

used, and was in daily operation in Baltimore in 1886. It is a very

cheap system and well adapted to roads owning the right of way or

running upon elevated tracks, but could not be used on public highways

or streets. The third-rail system in its simplest form is shown in

Fig. 29, which represents a section through the roadbed. The log _A_

represents a tie or sleeper, and _c c_ are the track rails, while _b_

is the third rail through which the current passes to the motors.

Between the rail _b_ and the tie _A_ is placed a piece of insulating

material, _a_, of such dimensions as may be necessary. If the track is

high above the surrounding ground, so as to not be submerged when there

is a heavy fall of rain, _a_ may be thin, but otherwise it must be of

sufficient thickness to raise the rail above the high-water mark. The

car is provided with a wheel or brush to bear upon the rail _b_.

This is the construction used upon the New York, New Haven, and

Hartford Railroad, as can be seen from Fig. 30, which is a photograph

of a section of the road. The third rail, it will be seen, is raised

but slightly from the ties, just about as shown in Fig. 29. One

objection to this construction is that persons and animals can receive

shocks by touching the center rail and one of the side ones at the same

time, as, for example, by standing with one foot on each. Such shocks

would not prove fatal to men, as the currents used for railway work

are not of a sufficiently high electro-motive force to produce death,

but the shock is nevertheless very severe. Horses and cattle would be

killed outright, as these animals are not able to withstand as strong

a shock as human beings. To render the third-rail system safer, and

also to improve the insulation of the conducting rail, the construction

illustrated in Fig. 31 has been devised. The only difference between

it and Fig. 29 is that the rail _b_, instead of resting upon the ties

between the tracks, is carried upon a side support _c c_ and is housed

in with boards _a a_. To take the current from it a wheel is mounted

upon a shaft projecting from the side of the car truck.

[Illustration: FIG. 32--ELECTRIC LOCOMOTIVE ON THE BUFFALO AND LOCKPORT

RAILWAY.]

From the foregoing brief description of the essential features of the

several systems devised for conveying current to the moving car by

means of conductors placed underground or upon the surface, it can

be seen that while the result can be accomplished in many ways, and

is actually accomplished in a number of instances, nothing has been

brought forward so far that is as free from objection as the simple

trolley, if we disregard the unsightliness of the latter. It is this

unsightliness that has created a demand for something else, but the

substitutes, while capable of doing the work, are far more costly and

can not be said to be as reliable under all conditions of weather.

The sphere of action of the electric-railway motor is not confined to

street railways or suburban transit, but extends to the legitimate

domain of the steam locomotive. In many places electric locomotives are

used to move freight trains made up of cars of the largest capacity,

this same work having been done formerly by steam locomotives. In

the city of Baltimore, the Baltimore and Ohio Railroad uses electric

locomotives, of greater capacity than any steam locomotives so far

made, to draw trains through the tunnel that passes under the city. The

general appearance of an electric locomotive can be judged from Fig.

32, which shows an engine of average size at the head of a long freight

train.

MM. Bertaux and G. Yver are quoted, in _La Nature_, as relating in

their travels in Italy that between Benevento and Foggia, where the

railway passes through a tract of wheat fields, a falcon was observed

closely accompanying the train. He would graze the windows, fly over

the roofs of the cars and turn, and keep constantly dashing down to

the ground by the side of the track. A habitual traveler on the road

remarked that he had observed this habit of the bird several times a

week. The crafty hawk had observed that the eddy made by the train as

it rushed through the air overcame the small birds and made them an

easy prey, and it had learned to take advantage of the fact. It was

also remarked that this particular train, which was the "fast train,"

was the only one the bird thus pursued.

A SURVIVAL OF MEDIÆVAL CREDULITY.

BY PROFESSOR E. P. EVANS.

One of the crassest and most impudent and yet most successful frauds of

modern times is that recently practiced by Leo Taxil and his associates

on the papal hierarchy in their pretended exposures of the Freemasons

and the Satanic rites performed by this secret fraternity. On April

20, 1884, Leo XIII issued an encyclical letter in which he divides the

human race "into two diverse and adverse classes" (_in partes duas

diversas adversasque_): "the kingdom of God on earth--namely, the

true Church of Jesus Christ"--and "the realm of Satan." All who are

not members of the former belong to the latter, so that there is no

alternative between being a good Catholic or a worshiper of the devil.

His Holiness then proceeds to show that the headquarters of Satanism

are the lodges of the Freemasons, a fact, he adds, fully recognized

by his predecessors, who have never ceased to expose and denounce the

diabolical character and flagitious aims of these archenemies of the

Christian faith. The detailed description of the organization of this

order, its devilish purposes, and the horrible crimes committed in

order to accomplish them are very queer reading in an official document

emanating from an infallible ecclesiastical authority at the close of

the nineteenth century. On August 20, 1894, Leo XIII published a decree

of the Inquisition putting under ban "Odd Fellows, Sons of Temperance,

and Knights of Pythias" as "synagogues of Satan," and excluding them

from the sacraments of the Church.

It is no wonder that such an exhibition of credulity, which excited

the astonishment of many a Romanist and made all intelligent and

unprejudiced persons smile and shrug their shoulders, should have

suggested to an arrant wag and incorrigible player of practical jokes

like Leo Taxil (pseudonym of Gabriel Jogand) the idea of appealing to

this peculiar passion on a grand scale and seeing to what extent the

"mother Church" could be led into fraud, as Milton says, like "Eve,

our credulous mother." In tracing the development of this audacious

plot through all its stages and perceiving by what silly tales and

transparent deceptions the Holy Father permitted himself to be duped,

one can hardly refrain from exclaiming, in the words of Ben Jonson:

"Had you no quirk

To avoid gullage, sir, by such a creature?"

Appletons' Popular Science Monthly, March 1900 Vol. 56, Nov. 1899 to April, 1900 · 第 5 / 11 段