Positive effect

Power: 227.5 p.s.i. x 2 (plungers) x 124 sq. in. (plunger area) 56,420 lb.

----------

Excess to overcome friction 5,090 lb.

Footnotes:

[1] Translated from Jean A. Keim, _La Tour Eiffel_, Paris, 1950.

[2] The foundation footings exerted a pressure on the earth of about 200

pounds per square foot, roughly one-sixth that of the Washington Monument,

then the highest structure in the world.

[3] A type of elevator known as the "teagle" was in use in some multistory

English factories by about 1835. From its description, this elevator

appears to have been primarily for the use of passengers, but it

unquestionably carried freight as well. The machine shown in figure 7 had,

with the exception of a car safety, all the features of later systems

driven from line shafting--counterweight, control from the car, and

reversal by straight and crossed belts.

[4] The Otis safety, of which a modified form is still used, consisted

essentially of a leaf wagon spring, on the car frame, kept strained by the

tension of the hoisting cables. If these gave way, the spring, released,

drove dogs into continuous racks on the vertical guides, holding the car

or platform in place.

[5] A notable exception was the elevator in the Washington Monument.

Installed in 1880 for raising materials during the structure's final

period of erection and afterwards converted to passenger service, it was

for many years the highest-rise elevator in the world (about 500 feet),

and was certainly among the slowest, having a speed of 50 feet per minute.

[6] Today, although not limited by the machinery, speeds are set at a

maximum of about 1,400 feet per minute. If higher speeds were used, an

impractically long express run would be necessary for starting and

stopping in order to prevent an acceleration so rapid as to be

uncomfortable to passengers and a strain on the equipment.

[7] Two machines, by Otis, in the Demarest Building, Fifth Avenue and 33d

Street, New York. They were in use for over 30 years.

[8] Although the eventually successful application of electric power to

the elevator did not occur until 1904, and therefore goes beyond the

chronological scope of this discussion, it was of such importance insofar

as current practice is concerned as to be worthy of brief mention. In that

year the first gearless traction machine was installed by Otis in a

Chicago theatre. As the name implies, the cables were not wrapped on a

drum but passed, from the car, over a grooved sheave directly on the motor

shaft, the other ends being attached to the counterweights. The result was

a system of beautiful simplicity, capable of any rise and speed with no

proportionate increase in the number or size of its parts, and free from

any possibility of car or weights being drawn into the machinery. This

system is still the only one used for rises of over 100 feet or so. By the

time of its introduction, motor controls had been improved to the point of

complete practicability.

[9] Mechanical transmission of power by wire rope was a well developed

practice at this time, involving in many instances high powers and

distances up to a mile. To attempt this system in the Eiffel Tower,

crowded with structural work, machinery and people, was another matter.

[10] According to Otis Elevator Company, the final price, because of

extras, was $30,000.

[11] In _Pall Mall Gazette_, as quoted in _The Engineering and Building

Record and the Sanitary Engineer_, May 25, 1889, vol. 19, p. 345.

[12] From speech at annual summer meeting of Institution of Mechanical

Engineers, Paris, 1889. Quoted in _Engineering_, July 5, 1889, vol. 48, p.

18.

[13] Located near the Tower, built for the Paris fair of 1878.

[14] Improved oil-well drilling techniques were influential in the intense

but short burst of popularity enjoyed by direct plunger systems in the

United States between 1899 and 1910. In New York, many such systems of

200-foot rise, and one of 380 feet, were installed.

[15] An obvious question arises here: What prevents a plunger 200 or 300

feet long and no more than 16 inches in diameter from buckling under its

compressive loading? The answer is simply that most of this length is not

in compression but in tension. The Edoux rams, when fully extended,

virtually hung from the upper car, sustained by the weight of 500 feet of

cable on the other side of the sheaves. As the upper car descended this

effect diminished, but as the rams moved back into the cylinders their

unsupported length was correspondingly reduced.

[16] M. A. Ansaloni, "The Lifts in the Eiffel Tower," quoted in

_Engineering_, July 5, 1889, vol. 48, p. 23. The strength of steel when

drawn into wire is increased tremendously. Breaking stresses of 140,000

p.s.i. were not particularly high at the time. Special cables with

breaking stresses of up to 370,000 p.s.i. were available.

Transcriber's Notes:

Passages in italics are indicated by _underscore_.

The original was printed in two columns per page.

Illustrations have been moved to the nearest paragraph break.

The following misprints have been corrected:

"Trevethick's" corrected to "Trevithick's" (page 5)

"then" corrected to "than" (page 14)

"smiliar" corrected to "similar" (page 31)

Elevator Systems of the Eiffel Tower, 1889 · 第 27 / 27 题