CHAPTER VIII.

STORM WATER IN SEWERS.

If the whole area of the district is not impermeable the

percentage which is so must be carefully estimated, and will

naturally vary in each case. The means of arriving at an

estimate will also probably vary considerably according to

circumstances, but the following figures, which relate to

investigations recently made by the writer, may be of interest.

In the town, which has a population of 10,000 and an area of

2,037 acres, the total length of roads constructed was 74,550

lineal feet, and their average width was 36 ft, including two

footpaths. The average density of the population was 4.9 people

per acre. Houses were erected adjoining a length of 43,784

lineal feet of roads, leaving 30,766 lineal feet, which for

distinction may be called "undeveloped"--that is, the land

adjoining them was not built over. Dividing the length of road

occupied by houses by the total number of the inhabitants of

the town, the average length of road per head was 4.37 ft, and

assuming five people per house and one house on each side of

the road we get ten people per two houses opposite each other.

Then 10 x 4.37 = 43.7 lineal feet of road frontage to each pair

of opposite houses. After a very careful inspection of the

whole town, the average area of the impermeable surfaces

appertaining to each house was estimated at 675 sq. ft, of

which 300 sq. ft was apportioned to the front roof and garden

paths and 375 sq. ft to the back roof and paved yards. Dividing

these figures by 43.71 in ft of road frontage per house, we

find that the effective width of the impermeable roadway is

increased by 6 ft 10 in for the front portions of each house,

and by a width of 8 ft 7 in, for the back portions, making a

total width of 36 ft + 2(6 ft 10 in) + 2(8 ft 7 in) = 66 ft 10

in, say 67 ft On this basis the impermeable area in the town

therefore equals: 43,7841 in ft x 67 ft =2,933,528; and 30,766

lin ft x 36 ft = 1,107,576.

Total, 4,041,104 sq. ft, or 92.77 acres. As the population is

10,000 the impermeable area equals 404, say, 400 sq. ft per

head, or ~ (92.77 x 100) / 2037 = 4.5 per cent, of the whole

area of the town.

It must be remembered that when rain continues for long

periods, ground which in the ordinary way would generally be

considered permeable becomes soaked and eventually becomes more

or less impermeable. Mr. D. E. Lloyd-Davies, M.Inst.C.E., gives

two very interesting diagrams in the paper previously referred

to, which show the average percentage of effective impermeable

area according to the population per acre. This information,

which is applicable more to large towns, has been embodied in

Fig. 16, from which it will be seen that, for storms of short

duration, the proportion of impervious areas equals 5 per cent.

with a population of 4.9 per acre, which is a very close

approximation to the 4.5 per cent. obtained in the example just

described.

Where the houses are scattered at long intervals along a road

the better way to arrive at an estimate of the quantity of

storm water which may be expected is to ascertain the average

impervious area of, or appertaining to, each house, and divide

it by five, so as to get the area per head. Then the flow off

from any section of road is directly obtained from the sum of

the impervious area due to the length of the road, and that due

to the population distributed along it.

[Illustration: FIG. 16.--VARIATION IN AVERAGE PERCENTAGE OF

EFFECTIVE IMPERMEABLE AREA ACCORDING TO DENSITY OF POPULATION.]

In addition to being undesirable from a sanitary point of view,

it is rarely economical to construct special storm water

drains, but in all cases where they exist, allowance must be

made for any rain that may be intercepted by them. Short branch

sewers constructed for the conveyance of foul water alone are

usually 9in or 12 in in diameter, not because those sizes are

necessary to convey the quantity of liquid which may be

expected, but because it is frequently undesirable to provide

smaller public sewers, and there is generally sufficient room

for the storm water without increasing the size of the sewer.

If this storm water were conveyed in separate sewers the cost

would be double, as two sewers would be required in the place

of one. In the main sewers the difference is not so great, but

generally one large sewer will be more economical than two

smaller ones. Where duplicate sewers are provided and arranged,

so that the storm water sewer takes the rain-water from the

roads, front roofs and gardens of the houses, and the foul

water sewer takes the rain-water from the back roofs and paved

yards,

it was found in the case previously worked out in detail that

in built-up roads a width of 36 ft + 2 (8 ft 7 in) = 53 ft 2

in, or, say, 160 sq. ft per lineal yard of road would drain to

the storm water sewer, and a width of 2 (6 ft 10 in) = 13 ft 8

in, or, say, 41 sq. ft per lineal yard of road to the foul

water sewer. This shows that even if the whole of the rain

which falls on the impervious areas flows off, only just under

80 per cent. of it would be intercepted by the special storm water

sewers. Taking an average annual rainfall of 30 in, of which 75 per

cent. flows off, the quantity reaching the storm water sewer in the

course of a year from each lineal

30 75

yard of road would be --- x 160 x --- = 300 cubic

12 100

feet = 1,875 gallons.

[Illustration: FIG. 17.--SECTION OF "LEAP WEIR" OVERFLOW]

The cost of constructing a separate surface water system will

vary, but may be taken at an average of, approximately, l5s.

0d. per lineal yard of road. To repay this amount in thirty years

at 4 per cent, would require a sum of 10.42d., say 10-1/2d. per annum;

that is to say, the cost of taking the surface water into special

10-1/2 d. x 1000

sewers is ---------------- = 5.6, say 6d. per 1,000

1875

gallons.

If the sewage has to be pumped, the extra cost of pumping by

reason of the increased quantity of surface water can be looked

at from two different points of view:--

1. The net cost of the gas or other fuel or electric current

consumed in lifting the water.

2. The cost of the fuel consumed plus wages, stores, etc., and

a proportion of the sum required to repay the capital cost of

the pumping station and machinery.

The extra cost of the sewers to carry the additional quantity

of storm water might also be taken into account by working out

and preparing estimates for the alternative schemes.

The actual cost of the fuel may be taken at approximately 1/4

d. per 1,000 gallons. The annual works and capital charges,

exclusive of fuel, should be divided by the normal quantity of

sewage pumped per annum, rather than by the maximum quantity

which the pumps would lift if they were able to run

continuously during the whole time. For a town of about 10,000

inhabitants these charges may be taken at 1-1/4 d. per 1,000

gallons, which makes the total cost of pumping, inclusive of

capital charges, 1-1/2 d. per 1,000 gallons. Even if the extra

cost of enlarging the sewers is added to this sum it will still

be considerably below the sum of 6 d., which represents the

cost of providing a separate system for the surface water.

Unless it is permissible for the sewage to have a free outlet

to the sea at all states of the tide, the provision of

effective storm overflows is a matter of supreme importance.

Not only is it necessary for them to be constructed in well-

considered positions, but they must be effective in action. A

weir constructed along one side of a manhole and parallel to

the sewer is rarely efficient, as in times of storm the liquid

in the sewer travels at a considerable velocity, and the

greater portion of it, which should be diverted, rushes past

the weir and continues to flow in the sewer; and if, as is

frequently the case, it is desirable that the overflowing

liquid should be screened, and vertical bars are fixed on the

weir for the purpose, they block the outlet and render the

overflow practically useless.

Leap weir overflows are theoretically most suitable for

separating the excess flow during times of storm, but in

practice they rarely prove satisfactory. This is not the fault

of the system, but is, in the majority of the cases, if not

all, due to defective designing. The general arrangement of a

leap weir overflow is shown in Fig. 17. In normal circumstances

the sewage flowing along the pipe A falls down the ramp, and

thence along the sewer B; when the flow is increased during

storms the sewage from A shoots out from the end of the pipe

into the trough C, and thence along the storm-water sewer D. In

order that it should be effective the first step is to

ascertain accurately the gradient of the sewer above the

proposed overflow, then, the size being known, it is easy to

calculate the velocity of flow for the varying depths of sewage

corresponding with minimum flow, average dry weather flow,

maximum dry weather flow, and six times the dry weather flow.

The natural curve which the sewage would follow in its downward

path as it flowed out from the end of the sewer can then be

drawn out for the various depths, taking into account the fact

that the velocity at the invert and sides of the sewer is less

than the average velocity of flow. The ramp should be built in

accordance with the calculated curves so as to avoid splashing

as far as possible, and the level of the trough C fixed so that

when it is placed sufficiently far from A to allow the dry

weather flow to pass down the ramp it will at the same time

catch the storm water when the required dilution has taken

place. Due regard must be had to the altered circumstances

which will arise when the growth of population occurs, for

which provision is made in the scheme, so that the overflow

will remain efficient. The trough C is movable, so that the

width of the leap weir may be adjusted from time to time as

required. The overflow should be frequently inspected, and the

accumulated rubbish removed from the trough, because sticks and

similar matters brought down by the sewer will probably leap

the weir instead of flowing down the ramp with the sewage. It

is undesirable to fix a screen in conjunction with this

overflow, but if screening is essential the operation should be

carried out in a special manhole built lower down the course of

the storm-water sewer. Considerable wear takes place on the

ramp, which should, therefore, be constructed of blue

Staffordshire or other hard bricks. The ramp should terminate

in a stone block to resist the impact of the falling water, and

the stones which may be brought with it, which would crack

stoneware pipes if such were used.

In cases where it is not convenient to arrange a sudden drop in

the invert of the sewer as is required for a leap weir

overflow, the excess flow of storm-water may be diverted by an

arrangement similar to that shown in Fig. 18. [Footnote: PLATE

IV] In this case calculations must be made to ascertain the

depth at which the sewage will flow in the pipes at the time it

is diluted to the required extent; this gives the level of the

lip of the diverting plate. The ordinary sewage flow will pass

steadily along the invert of the sewer under the plate until it

rises up to that height, when the opening becomes a submerged

orifice, and its discharging capacity becomes less than when

the sewage was flowing freely. This restricts the flow of the

sewage, and causes it to head up on the upper side of the

overflow in an endeavour to force through the orifice the same

quantity as is flowing in the sewer, but as it rises the

velocity carries the upper layer of the water forward up the

diverting plate and thence into the storm overflow drain A deep

channel is desirable, so as to govern the direction of flow at

the time the overflow is in action. The diverting trough is

movable, and its height above the invert can be increased

easily, as may be necessary from time to time. With this

arrangement the storm-water can easily be screened before it is

allowed to pass out by fixing an inclined screen in the

position shown in Fig. 18. [Footnote: PLATE IV] It is loose, as

is the trough, and both can be lifted out when it is desired to

have access to the invert of the sewer. The screen is self-

cleansing, as any floating matter which may be washed against

it does not stop on it and reduce its discharging capacity, but

is gradually drawn down by the flow of the sewage towards the

diverting plate under which it will be carried. The heavier

matter in the sewage which flows along the invert will pass

under the plate and be carried through to the outfall works,

instead of escaping by the overflow, and perhaps creating a

nuisance at that point.