CHAPTER X

-------

118. EDISON’S EXPERIMENTS. CHARACTERISTICS OF DISCHARGE TUBE,

PHOTOGRAPHIC PLATES, ELECTRICAL APPARATUS, FLUORESCENCE, ETC. _Elec.

Eng._, N.Y., Feb. 19, ’96; Mar. 18 and 25; Apr. 1, 8, 15 and 29, ’96.

X-RAYS BEGIN BEFORE STRIAE END.—The reader may remember a former

section, § 10, pointing out that striae were usually obtainable without

very high vacua, and that phosphorescence of the glass occurs only with

high vacua. § 54. In carrying the vacuum up higher and higher, Edison

observed that feeble Roentgen rays were detected before the striae

ceased. Prof. Elihu Thomson independently performed a like experiment

and found that the Roentgen rays could be obtained even when the vacuum

was so low as to produce striae. (_Elec. Eng._, N.Y., Apr. 15, ’96.)

Victor Chabaud and D. Hurmuzescu also obtained X-rays from a vacuum .025

mm., being lower than Crookes employed, which was at a maximum .001 mm.

(_L’Industrie Elect._, Paris, May 25, ’96. From trans. by Louis M.

Pignolet.)

119. REASON WHY THIN WALLS ARE BETTER THAN THICK. X-RAYS AND

POST-PHOSPHORESCENCE.—This may be understood by explanation of the

discharge tube in Fig. 1. In one experiment, the portion struck by the

cathode rays, namely B, was made 1/8 inch thick. It became soon hot and

very luminous and melted, § 61, but the X-rays were weak. When blown

thin, (§ 83) however, the glass remained cool and the X-rays were much

stronger. What is known on the market as German glass (phosphoresces

green, § 55, at centre) was found more permeable than lead glass, the

thickness of the walls being the same in both cases. There were no

lingering X-rays from after-phosphorescence, (§ 54, at end) or, if any,

could not be detected by the sciascope. The photographic test would be

objectionable because of the brief duration. Prof. Battelli and Dr.

Garbasso, of Pisa, made a very _sensitive_ test in this connection,

proving by the discharge of an electrified body (§ § 90 and 90_a_) that

feeble X-rays were emitted after the current was cut off from the

discharge tube. (From trans. by Mr. Pignolet.)

[Illustration:

DISCHARGE TUBE, FIG. 1. § 119.

DISCHARGE TUBE, FIG. 3. § 120.

]

120. TO PREVENT PUNCTURE OF THE DISCHARGE TUBE BY SPARKS.—In the

illustration, Discharge Tube Fig. 2. shows a suitable type. It is drawn

to scale, showing the correct proportion of the length to the diameter.

The shaded ends represent tinfoil on the outside and connecting with the

leading-in wires, the same preventing puncture of the glass by the

spark. They may be caused to adhere by shellac or similar glue. In place

of the metallic coating detached supplementary electrodes may be

employed, as seen in the illustration marked “Discharge Tube Fig. 3.”

The power of the X-rays was increased, being due, it was thought, to the

fact that the construction embodied the combination of internal and

external electrodes. § 121.

121. VARIATION OF VACUUM BY DISCHARGE AND BY REST.—Prof. Pupin was among

the first to test the efficiency of external electrodes for generating

X-rays. Independently of the quality of the glass and of the kind of

pump and of the presence or absence of phosphoric anhydride, the

following peculiarities were noticed, which Edison attributed to a kind

of atomic electrolysis. § 47. 80 per cent. of the lamps exhibited the

phenomena as follows: First, such a high vacuum was obtained by the pump

that the line spectrum disappeared and pure fluorescence and generation

of X-rays at a maximum occurred. The lamp was then sealed off. After

three or four hours of rest, the vacuum deteriorated, so that striae and

other characteristics of low vacuum were obtained when connected up in

circuit, but upon continuing the current, the high vacuum gradually came

back, the line spectrum vanished, and suddenly X-rays were generated.

Again the bulb was left at rest for 24 hours, after which X-rays could

not be generated until the discharge had been continued for 4-1/2 hours.

[Illustration:

DISCHARGE TUBE, FIG. 2. § 120.

]

122. EXTERNAL ELECTRODES DISCHARGE THROUGH HIGHER VACUUM THAN

INTERNAL.—A vacuum that was so high that no discharge took place with

internal electrodes was made luminous by the use of electrodes on the

outside of the glass bulb. Then he made the vacuum so high that even

with a 12-inch spark from Leyden jars, no discharge took place with

external electrodes, and the tube was dark, this part of the experiment

indicating another limit at which an extremely high vacuum is not a

conductor and appearing to overthrow, as Edison intimated, Edlund’s

theory that a vacuum is a perfect conductor. § 25.

123. DEPOSIT ON GLASS FROM ALUMINUM ELECTRODE.—It has always been common

to employ aluminum for electrodes in vacuum tubes, on the ground that no

deposit took place, and therefore no blackening, nor whitening of the

glass wall. § 40. Edison observed also that no blackening was visible,

but stated that his glass blower, Mr. Dally, upon breaking the bulb and

submitting the interior surface of the glass to an oxydizing process,

the oxide of aluminum was so thick as to be opaque to light. With

magnesium, also, a mirror was produced, of a lavender color, by

transmitted light. In the case of aluminum, he was able to obtain a

visible spot at the phosphorescent portion, but only after a great many

hours of use. See cut from a photograph of a discharge tube used for

several months by Prof. Dayton C. Miller, and having a heavy aluminum

deposit opposite the aluminum cathode. With the increase of the deposit,

the power of the X-rays diminished, but, he thought, not on account of

the absorption, but because, “through lack of elasticity at the

surface.”

[Illustration:

DISCHARGE TUBE, § 123.

]

124. FLUORESCENT LAMP. In an English patent of ’82, granted to Rankin

Kennedy, there is described a vacuum bulb in which the electrodes are

covered with fluorescent or phosphorescent substances, intended for the

purpose of obtaining greater candle power by impact of cathode rays upon

anode of platinum, covered with alumina or magnesia. Edison coated the

inner wall of the discharge tube, for generating X-rays, with calcic

tungstate in the crystalline form. The luminosity, when measured,

amounted to about 2-1/2 C. P. As to the efficiency, he stated that this

was accomplished “with an extremely small amount of energy.” Such a

coating was found to weaken the X-rays radiated therefrom, which, of

course, was natural, because they had been converted into phosphorescent

light. The spectrum showed strongly at the red line, thereby suggesting

the reason why the light was of a pleasant character.

124_a_. PILTCHIKOFF’S EXPERIMENT. Greater emission of X-rays by a tube

containing an easily fluorescent substance. _Comptes Rendus_, Feb., 24,

’96. From trans. by Mr. Louis M. Pignolet. As the X-rays emanate from

the fluorescent spots on the glass of the discharge tube, he reasoned

that more powerful effects would be obtained by replacing the glass by a

more fluorescent material. He therefore tried a Puluj tube and found

that it shortened the time necessary for taking a photograph in a

“singular” degree. Experiments of others have certainly shown that as

phosphorescence decreases with increase of vacuum, the X-rays increase

to a certain maximum, § 105. Let it be noticed however, that this does

not prove that with the same vacuum, an increase of phosphorescence by a

superior phosphorescent material of equal thickness would not increase

the power of the X-rays. The best way to determine such points, is to go

to extremes. Edison applied so much easily phosphorescent material

(calcic tungstate) to the inside of the discharge tube, that much light

was radiated, but only feeble X-rays. On the other hand, without any of

the tungstate, the rays were strong, § 124. Experiments generally tend

to prove that it depends upon the chemical nature of the material rather

than its phosphorescing power, in other words upon the permeability. §

119, near end.

125. ELECTRODES OF SILICON CARBIDE. (Carborundum.) Edison called

attention to Tesla’s discovery that this substance is a good conductor

for high tension currents. Its advantages for electrodes in the

discharge tube are its high conductivity, no absorbed nor released gas

bubbles, and its infusibility and non-blackening power of glass even

when the voltage was increased to a point where the glass melted.

[Illustration:

EDISON (AT RIGHT) AND T. COMMERFORD MARTIN USING THE SCIASCOPE. § 97,

p. 84.

Cut also shows Sprengel vacuum-pump. Discharge-tube is in the box.

]

126. CHEMICAL DECOMPOSITION OF THE GLASS BULB. During the generation of

the X-rays the sodium line of the spectrum appeared in the spectroscope,

thereby indicating decomposition of the glass. With combustion tubes the

glass gave the weakest soda line, while lime soda glass gave the

strongest, and was most permeable to the X-rays. “The continuous

decomposition of the glass makes it almost impossible to maintain a

vacuum except when connected to the pump and even then the effect of the

current is greater in producing gas than the capacity of the pump to

exhaust, but the ray is very powerful.” It is supposed that for this

reason, as well as for others easily apparent that Edison as well as

other experimenters have always carried on their investigations with the

discharge tube permanently connected to the pump. The next best thing is

to let the tube contain a stick of caustic potash for maintaining an

exceedingly high vacuum. By gradually heating this, the desired degree

of vacuum can be obtained. § 54.

127. SCIAGRAPHS. DURATION OF EXPOSURE DEPENDENT UPON DISTANCES. With the

given discharge tube, he obtained sciagraphs at a distance of 3/8 inch

from the phosphorescent spot in one second, a vulcanized cover being

between; at two ft. distant the time was 150 sec.; at three ft., 450

sec.; the opaque plate being interposed each time. Consequently

“Roughly, the duration of exposure may be reckoned as proportional to

the square of the distance.”

128. DIFFERENCE BETWEEN X-RAYS AND LIGHT ILLUSTRATED BY DIFFERENT

PHOTOGRAPHIC PLATES. TIME OF EXPOSURE. The rapid plate for light gave

not the deepest images by X-rays. Several different kinds of small

sensitive plates were laid side by side. A sciagraph of a metal bar was

taken upon them all simultaneously. In this way, he obtained the result,

whereby it would appear preferable to employ the mean rapid plate for

the purpose of obtaining sciagraphs. On account of the opacity of

platinum, it occured to E. B. Frost, (_Sci._, N.Y., Mar. 27, ’96,) to

try platinum photographic paper of the kind used for portraits, but such

paper (intended for long exposures in printing in sunlight) was far too

lacking in sensitiveness to produce any effect.

128_a_. GEORGES MESLINS INSURED A REDUCTION OF TIME FOR TAKING

SCIAGRAPHS BY THE DEFLECTION OF THE CATHODE RAYS BY MEANS OF A MAGNETIC

FIELD. _Comptes Rendus_, March 23 and 30, 1896. From trans. by Louis M.

Pignolet. The method consists in using a permanent or electro-magnet to

create a magnetic field perpendicular to the cathode rays in the tube.

By this means, the active fluorescent spot on the tube is condensed, and

the intensity of the X-rays generated there is increased. Another

advantage is that, when the active part of the tube becomes inactive

owing to the formation of a light brown deposit upon it, another part

can be used by very slightly altering the position of the magnets. Thus,

each time a new part of the tube can be used. The magnetic field must

not be uniform but must have a suitable variation to produce the desired

concentration of the cathode rays.

A. IMBERT AND H. BERTIN-SANS’ EXPERIMENT. (_Comptes Rendus_, March 23,

’96. (From trans. by L. M. P.) They shortened the time by use of a

magnet.

JAMES CHAPPIN’S EXPERIMENT. (_Comptes Rendus_, Mar. 30,’96. (From trans.

by L. M. P.)—Claimed priority in having shown publicly, on Feb. 19, a

sciagraph of a hand, marked “Photograph obtained by concentration of the

cathode rays, by means of a magnetic field.” The increase of the

intensity of the X-rays obtained by this means was in the proportion of

8 to 5, as measured by the time of fall of the leaves of a Hurmuzescu

electroscope.

Prof. Trowbridge, of Harvard University, in a lecture, gave an

interesting review (_Western Elect._, Feb. 29, ’96) of the length of

time required in the early days of photography. Improvements are being

made whereby the duration required in sciagraphy becomes less and less.

In 1827, by heliography, 6 hours’ exposure was necessary; in 1839, by

daguerreotype, 30 minutes; in 1841, by calotype, 3 minutes; in 1851, by

collodion, 10 seconds; in 1864, by collodion, 5 seconds; in 1878, by

gelatine, 1 second. The author remembers the photographs for use in the

Edison kinetoscope were taken at the rate of 20 per second. The focus

tube brings the time of exposure in behalf of X-rays down to a matter of

seconds instead of minutes. For an admirable review of authorities,

facts and theories relating to the causes of the darkening of

photographic plates by light, see Cottier, in _Elect. World_, N.Y., May

23, ’96.

129. SIZE OF DISCHARGE TUBE TO EMPLOY FOR GIVEN APPARATUS.—A small tube

required but a small E. M. F., and therefore should be employed with a

small induction coil. The greater the distance of the sensitive plate

and the object, considered together, from the discharge tube, the

sharper the shadow. In short exposures, the tube should be small and at

a short distance.

130. PREVENTING PUNCTURE AT THE PHOSPHORESCENT SPOT.—In experiments

where he employed a flat cathode, a very thin pencil of rays of

increased power came from the exact centre, and in two or three seconds

made the glass red hot at the centre of the phosphorescent spot.

Immediately, the atmospheric pressure perforated the bulb. This occurred

several times. He stated that “the best remedy is to permit the central

ray to strike the glass at a low angle; this greatly increases the area

and prevents the trouble.” EDISON.

Mr. Ludwig Gutmann furnished a translation of a note by Prof. Walter

König, found in _Eleck. Zeit._ of May 14, ’96, relating to this same

subject matter. Recognizing that the sharpness of the outlines is the

most important requirement in connection with sciagraphy, and that if

the rays start from a large surface the impressed shadows will be

uncertain in configuration, and noticing, as Edison and Tesla did, §

130, the frequent destruction of the tube at the place where the rays

were concentrated to a focus, he placed over the inner surface of the

glass, aluminum foil for distributing the heat over a larger area, at

the same time causing radiation of X-rays from a single point. The focus

tube outweighs this in importance. § 91.

131. ELECTRICAL DIMENSIONS OF APPARATUS. The best kind of instruction

for the student in reference to equipping a plant is to follow the

construction employed by those who have been successful. § § 106, 109,

114, 137. Edison used the usual incandescent-lamp current, voltage at

110 to 120 volts, current being continuous, but not connected directly

to the induction coil, there being a bank of eight to twenty 16 candle

power incandescent lamps arranged in parallel. The interrupter for the

primary consisted of a rotating wheel in appearance like a commutator of

a dynamo, and was rotated rapidly by a small electric motor, making

about 400 interruptions per second, and so constructed that the circuit

was closed twice as long as it was open. A sudden interruption was

caused by an air blast playing at the point of make and break, the use

of which made that of a condenser needless. § 3. The discharge tube

terminals were connected respectively and directly to those of the

secondary. Prof. Pupin, Columbia Univ. N.Y. (_Lect. N.Y., Acad. Sci._,

April 6, ’96, and _Science_, N.Y., April 10, ’96) gave valuable and

practical instruction concerning the apparatus, which the author

witnessed. “A powerful coil was found indispensable for strong effects

and satisfactory work. The vibrating interrupter is too slow and

otherwise unsatisfactory, and it was replaced by a rotary interrupter,

consisting of a brass pulley, 6 inches in diameter and 1-1/4 inches in

thickness. A slab of slate 3/4 inch thick was inserted and the

circumference was kept carefully polished. This pulley was mounted on

the shaft of a Crocker-Wheeler 1/8 H. P. motor giving 30 revolutions,

and, therefore, 60 breaks per second. Two adjustable Marshall condensers

of three microfarads each were connected in shunt with the break, and

the capacity adjusted carefully until the break-spark was a minimum and

gave a sharp cracking sound. Too much capacity will not necessarily

increase the sparking, but it will diminish the inductive effect which

is noticed immediately in the diminished intensity of the discharge. A

powerful coil with a smoothly working rotary interrupter will be found a

most satisfactory apparatus in experiments with Röntgen radiance.” §

106, 109, 114, 131, 137.

132. SALTS FLUORESCENCE BY X-RAYS. See also, _Elect. Rev._, N.Y., April

19, ’96, p. 165. Edison examined over 1800 chemicals to detect and

compare their fluorescent powers if any, under the action of X-rays

first transmitted through some opaque material such as thick cardboard.

Of all these, calcic tungstate by measurement, fluoresced with six times

the luminosity of barium platino cyanide, which was referred to in

connection with Roentgen’s experiment. Other authorities agree as to its

great sensitiveness. In making this comparison, it was assumed that the

power of the X-rays varied inversely as the square of the distance from

the discharge tube. Between the two above chemicals came strontic

tungstate. Baric and plumbic tungstate scarcely fluoresced. Salicylate

of ammonium crystals equalled the double cyanide of platinum and barium,

and differed therefrom in that the fluorescence increased with the

thickness of the layer of crystals up to 1/4 of an inch, showing great

fluorescing power and low absorptivity. This experiment showed that the

best fluorescent materials were not necessarily the salts of the

heaviest metals, like platinum. It is assumed that the reader knows the

difference between phosphorescence and fluorescence, but the dividing

line is so difficult in some cases and the one not being distinguished

from the other by experimenters, that the author has used the same words

as the experimenters, although he admits that fluorescence is often

meant where phosphorescence is stated, and _vice versa_. An anomaly

presented itself as to rock salt, which although transparent to light

yet powerfully absorbed X-rays and was strongly fluoresced thereby.

Again, fluorite which is transparent to light, fluoresced strongly with

the X-rays, and under their action became brighter and brighter and

continued after cutting off the X-rays, the material therefore, being

highly phosphorescent, the light enduring for several minutes. Upon

watching the phosphorescence of fluorite, the same penetrated the plate

very slowly to the depth of one-sixteenth of an inch, but beyond that

depth there was complete darkness. The only other truly phosphorescent

substance noticed was calcic tungstate, especially in thick layers, so

that the shadow of the bones of the hand remained thereon for a minute

or two upon cutting out the discharge tube from the circuit. Some

chemicals, within a dark box and _very close_ to the discharge tube,

phosphoresced by giving spots here and there, but they did not

phosphoresce at a greater distance, and the light was probably not due

to the X-rays. Edison attributed the result directly to the “electrical

discharge.” The list is as follows: ammonium sulphur cyanide, calcic

formate, and nitrate, ferric citrate, argentic nitrate, calcic and iron

citrate, soda, lime, “zinc, cyanide” (perhaps this means cyanide of

zinc), zinc hypermanganate, and zinc valeriate. The salts of the

following metals did not fluoresce under the influence of the X-rays.

Aluminum, antimony, arsenic, boron, beryllium, bismuth, barium,

chromium, cobalt, copper, gold, iridium, magnesium, manganese, nickel,

tin, and titanium.

[Illustration:

ROENTGEN RAYS AT THE UNIVERSITY OF MINNESOTA.

1. Watch and chain.

2. College badges in mahogany box.

3. Copper coin.

4. Weights in heavy velvet-lined mahogany box; blank space contains

aluminum.

5. Coins in inner pocket of heavy seal purse.

6 and 7. Colored glass.

8. Key

9. Lead-pencil.

_West. Elect._, Mar. ’96.

]

Edison stated that the following substances were among those which

fluoresced more or less under the action of the X-rays. Mercurous

chloride, mercury diphenyl, cadmic iodide, calcic sulphide, potassic

bromide, plumbic tetrametaphosphate, potassic iodide, plumbic bromide,

plumbic sulphate, fluorite, powdered lead glass, pectolite, sodic

cressotinate, ammonic salicylate, and salicylic acid. Compared with the

above, the following fluoresced less. Powdered German glass, baric,

calcic and sodic fluorides, sodic, mercuric, cadmic, argentic and

plumbic chlorides, plumbic iodide, sodic bromide, cadmic and “cadmium,

lithia bromide, mercury, cadmium sulphate,” uranic sulphate, phosphate,

nitrate, and acetate, molybdic acid, dry potassic silicate, sodic

bromide, wulfenite, orthoclase, andalucite, herdinite, pyromorphite,

apatite, calcite, danburnite, calcic carbonate, strontic acetate, sodic

tartrate, baric sulphobenzoic, calcic iodide, and natural and artificial

ammonium benzoic. Not one of all the 1800 crystals and precipitates

fluoresced through a thick cardboard under the influence of the arc

light, 16 inch spark in air, a vacuum tube so highly exhausted that a 10

inch spark left it dark, nor the direct rays of the sun at noon time. As

calcic tungstate was phosphorescent by friction, he theorized that the

X-ray is a wave due to concussion.

Flame sensitive to X-rays. Edison stated that his assistants submitted

the sensitive flame and the phonographic listening tube to the action of

the X-rays, and found that they were responsive thereto.

133. X-RAYS APPARENTLY PASSED AROUND A CORNER. Referring to the figure

“X-ray Diffusion Fig. 1”, p. 129, it will be noticed that there were

three principal elements. First a discharge tube, then a thick steel

plate and then a sciascope, all arranged in the proportion indicated in

the figure, where the sciascope was within six inches of the edge of the

plate, “well within the shadow” thereof. § 69. Fluorescence was seen

under these conditions. When the sciascope was directly behind the

middle of the plate and opposite the discharge tube, there was no

fluorescence, showing that the plate was thick enough to cut off all the

rays and therefore the energy must have traveled in two directions for

some reason or other.

Prof. Elihu Thomson remarked concerning this experiment that he

considered, in view of some experiments of his own, on diffusion and

opalescence (§ 103), that the sciascope was luminous in view of

reflection (§ 146) of the X-rays from various objects in the room, as

from the walls and floor of the room, tables, metal objects, electrical

apparatus and so on. Theory admits the property of diffraction, which

would cause the rays to turn around the edge of the plate, according to

the principles of diffraction of light, provided the X-rays were due to

transverse or longitudinal or any vibrations. See _Elect. Eng._, N.Y.,

April 15, p. 378.

While Edison generally devotes his energy to actual experiments and

dealings with facts and principles, rather than with theories, yet, in

this instance, he merely suggested that the fluorescence under the

conditions named might indicate that the propagation of X-rays was

similar to that of sound in air, the wave being of exceedingly short

length. He referred to Le Conte’s experiment of ’82 (see _Phil. Mag._,

Feb. ’82), where an experiment of a somewhat similar nature was

performed in connection with the propagation of sound.

[Illustration:

X-RAY DIFFUSION, FIG. 1, § 133.

]

Prof. William A. Anthony (see _Elect. Eng._, Apr. 3, ’96, p. 378) held

that the Le Conte experiment did not warrant Edison’s conclusion, for

the experiment of Le Conte showed comparatively sharp sound shadows; for

even at a distance of twelve feet there was no apparent penetration

within the geometrical boundary. He referred to Stine’s, § 110. Scribner

and M’Berty’s, § 111, as upholding rectilinear propagation. While he did

not explain what the Edison result was due to, yet he argued that the

cause was other than that ascribed by Edison. In this connection, the

author performed an experiment (_Elect. Eng._, Apr. 22, ’96, p. 409) to

substantiate that X-rays were propagated through such a high vacuum that

it was necessary to have electrodes within 1/8 of an inch of each other,

in order to obtain a discharge with a coil that gave 15 in. spark in

open air. The experiment consisted in casting the shadow of an

_uncharged_ tube upon the screen of a sciascope. The shadows of the wire

forming the electrodes within the vacuum were produced very sharply,

while the glass tube was faintly outlined. Inasmuch as the shadows of

objects _within_ the vacuum tube were obtained, therefore the X-rays

must have passed through the evacuated space. Sound and X-rays are

therefore dissimilar. The shadows were as sharp and as dark as those

made by similar wires in open air. In this connection, see also Lenard’s

experiment, § 72, showing that external cathode rays were also

transmitted by a vacuum in a “dead” tube. Roentgen’s experiment showed

that X-rays from a mass located entirely within the vacuum in the

discharge tube radiated X-rays into the outside atmosphere. § 91. This

experiment would hardly prove, however, that X-rays, after having been

liberated in open air, would pass through a second vacuum space, because

there may have been some X-rays, generated at the surface of the glass

in Roentgen’s experiment, struck by those rays which radiated from the

mass at the centre of the vacuum space. Did not Lenard and Roentgen

experiment with the same radiant energy? The author answers, yes. § 77.

134. PERMEABILITY OF DIFFERENT SUBSTANCES. Lenard § 68. determined the

permeability of several substances to cathode rays. Roentgen also the

same in regard to X-rays. § 82 and 83. Others have made comparisons.

From the sciagraph made by Edison, the following classification is made,

each sheet of material being about 1/32 inch thick. The most opaque were

coin silver, antimony, lead, platinum, bismuth, copper, brass, and iron,

which were about the same as one another. Slate, ivory, glacial

phosphoric acid shellacked, and gutta percha, were about the same as one

another and less than the above. Aluminum, tin, celluloid, hard rubber,

soft rubber, vulcanized fibre, paper, shellac, gelatine, phonographic

cylinder composition, asphalt, stearic acid, rosin, and albumen, were

about the same as one another and less than the above group, as to

permeability.

The accompanying picture, p. 6, marked Terry’s Sciagraph, Fig. 1, is a

sciagraph of pieces of different materials named as in the following

list, taken by Prof. N. M. Terry of the U.S.N.A., see also p. 127. “1,

rock salt, 0.6 inch thick; 2, cork, 0.4 inch thick; 3, quartz, 0.45 inch

thick, cut parallel to optic axis; 4, verre trempe, 0.4 inch thick; 5,

glass, 0.7 inch thick; 6, chalk; 7, Iceland spar; 8, mica, very thin; 9,

quartz, over a square piece of glass; 10, aluminum foil, [_a_] four

thicknesses, [_b_] two thicknesses, [_c_] one thickness; 11, platinum

foil; 12, tourmaline; 13, aragonite; 14, paraffine, 0.4 inch thick. 15,

tin foil, [_a_] one thickness, [_b_] two thicknesses, [_c_] three

thicknesses; 16, rubber insulated wire; 17, electric light carbon; 18,

glass, 0.32 inch thick; 19, alum., 1.4 inch thick; 20, tourmaline; 21,

gas coal; 22, bee’s wax; 23, pocket-book, 10 thicknesses of leather; 24

coin in pocket-book; 25, key in pocket-book; 26, machine oil in ebonite

cup; 27, ebonite, 0.25 inch thick; other samples have given very faint

shadows like wood and leather; this was polished; 28, wood, 0.2 inch

thick; 29, steel key.” _Elect. Eng._, N.Y.

134_a_. HODGES’ EXPERIMENT. ILLUSTRATION OF PENETRATING POWER OF LIGHT.

_Elec. Eng._, N.Y., March 4, ’96. Attention has been invited in the

scientific press to the penetrating power of heat rays and of light rays

of low refrangibility. In conjunction with this, let it be remembered

that the photographic plate has the property of being impressed

practically, only by rays having a higher refrangibility than red. It

would be natural, therefore, to conclude that if the spectrum could be

turned around, the photographic impression might be produced through

opaque bodies. This perhaps, was the kind of reasoning which prompted

Mr. N. D. C. Hodges, formerly editor of _Science_, to perform an

experiment, the gist of which consisted in attesting the permeability of

rays of light which had been passed through fuchsine. Christiansen,

Soret and Kundt performed experiments with an alcoholic solution of this

material and found that the order of the colors in the spectrum was

somewhat reversed, namely, violet was the least refracted, then red, and

then yellow, which was the most refracted. Mr. Hodges used a pocket

kodak, carrying a strip for twelve exposures. This camera was placed in

a closely fitting pasteboard box. Thus protected, some portions of the

film were exposed to sunlight, so far as it could penetrate the end of

the pasteboard box, while other exposures were made with a prism, on the

end of the box, containing an alcoholic solution of fuchsine. The

portions of film exposed to the anomalous rays produced by the fuchsine

solution were fogged, while the control experiments with ordinary light

showed none. The anomalous rays must have penetrated the pasteboard, and

probably the wood and leather of which the camera was made.

135. PENETRATING POWER OF X-RAYS INCREASED BY REDUCTION OF TEMPERATURE.

§ 23 and 72_b_ at end. Among the hundreds of ideas that occured to

Edison in connection with Roentgen ray tests was that concerning what

might happen by cooling the discharge tube to a very low temperature. As

before, he maintained the tube in connection with the air pump so as to

be able to vary the vacuum. The reduction of temperature was obtained by

means of ice water. Of course the bulb could not be placed in the water

itself on account of trouble which would occur from electrolysis,

therefore, the discharge tube was immersed in a vessel of oil, § 13,

which in turn was surrounded by a freezing mixture. The vessel was a

stout battery jar 14 inches high, eight inches in diameter with glass

walls 5/10 of an inch thick. The oil employed was paraffine. The

refrigerating jar was 12 inches high and 12 inches in diameter and the

glass wall thereof, 3/8 inch thick. He tested the difference in the

power of the rays by first noticing the thickness of steel that was not

penetrated by the rays generated from the tube while in air. Crucible

steel 1/16 of an inch thick did not transmit rays sufficiently to

illuminate the sciascope, and yet with the use of oil and reduction of

temperature, and after the rays had passed through two thicknesses of

glass as well as through the oil and ice water, the sciascope was made

luminous by rays after passing through a plate of steel of double the

thickness, __i.e.__ 1/8 in. thick. See in this connection, Tesla’s

experiment, § 135, where powerful rays were obtained by immersing the

discharge tube in oil. Accounts of these two experiments were published

simultaneously. Tesla attributed the idea of this use of oil to Prof.

Trowbridge of Harvard University, who showed that a discharge tube

immersed in oil is adapted to the generation of X-rays of increased

penetrating power. See cut at p. 135.

[Illustration:

SCIAGRAPH OF RATTLESNAKE BY USE OF STOPS. § 107., p. 101.

By Leeds and Stokes.

]

NON-REFLECTION OF X-RAYS. (_Elect. Eng._, Feb. 19, ’96, p. 190.

Apparently extracted from the daily press.)—That the X-rays were only

slightly reflected (Roentgen, § 81., and even when very powerful (Tesla,

§ 146., was determined in a severe manner by Edison. The first

experiment consisted in employing a funnel 8 inches long and 3/4 inch at

the smaller end. The discharge tube was in the larger end, and the

photographic plate across the smaller end. After experiment and

development, the plate showed overlapping circular images, which would

indicate reflection from the inner surface of the funnel. This may have

been due to a jarring vibration of the funnel. Therefore, he carried the

experiment further by using a funnel 9 feet long. The plate did not

indicate any signs of reflection, as it merely became generally fogged.

The material of the tube is not named, but if of brass or other

impermeable metal, it is thought that his experiment would have shown a

result agreeing with that of others herein. Again, the reporter may have

been in error. Also, the rays may have been very weak, as the experiment

was performed when Edison first started to investigate the subject.

136. X-RAYS NOT YET OBTAINABLE FROM OTHER SOURCES THAN DISCHARGE

TUBES.—Edison exposed covered plates to the direct sun-light at noon for

three or four hours; no photographic impression; also to electric sparks

in open air, of twelve or more inches in length; no clouding even of the

photographic plate.

Profs. Rowland et. al., of the Johns Hopkins University, in a

contribution to _Electricity_, Apr. 22, ’96, p. 219, confirmed this

point by stating: “As to other sources of Roentgen rays, we have tried a

torrent of electric sparks in air from a large battery, and have

obtained none. Of course, coins laid on or near the plate, under these

circumstances, produce impressions, but these are, of course, induction

phenomena.” (See Sandford and McKay’s Fig. p. 20). “As to sun-light,

Tyndall, Abney, Graham, Bell and others have shown that some of the rays

penetrate vulcanite and other opaque objects.” Poincaré, at an early

date, advanced the hypothesis that X-rays are due to phosphorescence,

whether produced by electrical or other means. _Elect. World_, Digest.,

Mar. 28, ’96, p. 343, where it is also stated that Chas. Henry thought a

certain experiment of his own was in favor of the hypothesis. The

experiment was performed with a phosphorescent material which had been

exposed to the light and then brought into darkness. Niewengloswski

inferred, from an experiment, that phosphorescent bodies increase the

penetrating power of sun-light. Tesla admitted the possibility of the

radiation of X-rays from the sun. In an article describing important

experiments in the _Elect. Rev._, N.Y., Apr. 22, ’96, p. 207, he stated:

“I infer, therefore, that the sun-light and other sources of radiant

energy must, in a less degree, emit radiations or streamers of matter

similar to those thrown off by an electrode in a highly exhausted

enclosure. This seems to be at this moment still a matter of

controversy.” Roentgen, in his first announcement, showed that the

phosphorescent spot was the source of the X-rays. § § 79 and 80. All the

different opinions and theories, therefore, indicated that

phosphorescence by sun-light might possibly emit X-rays. Probably few

had sufficient belief in the matter, one way or the other, to try the

experiment in an extreme manner. The author was curious to prove the

question, but he only obtained negative results. It cannot be conceived

how the matter could have been more severely tested, for he concentrated

the light of the sun nearly to a focus by a large lens, namely 5 in. in

diameter, together with a reflecting funnel. The maximum phosphorescence

was therefore obtained by placing suitable chemicals at the opening in

the funnel. The sciascope showed absolutely no X-rays present.

Photographic plates were not in the least acted upon, even after hours

of exposure, the same having opaque covers of aluminum. See _Elect.

Eng._, N.Y., Apr. 8, ’96, p. 356. If X-rays are emitted from the sun,

they are all absorbed by the atmosphere of the earth, or are overcome by

some other force.

[Illustration:

COOLING DISCHARGE TUBE. EDISON. § 135.

]

------------------------------------------------------------------------

Roentgen Rays and Phenomena of the Anode and Cathode. · 第 10 / 14 章