CHAPTER XI

HOUSE TRAPS, FRESH-AIR CONNECTIONS, DRUM TRAPS, AND NON-SYPHONING

TRAPS

The _house trap_ is a deep seal trap placed inside the foundation

wall, and intersects the house drain and house sewer. The trap is

placed at this point for a number of reasons: first, to keep sewer

gases from entering the pipes in the house; second, this location

is where the house drain ends. This trap should have two

clean-outs, one on each side of the seal. The clean-outs should be

of extra heavy cast-iron body with a heavy brass screw cap. The cap

should have a square nut for a wrench to tighten or unscrew the

cap. This cap should be brought up flush with the floor. When a

house trap is being set, it is necessary to set it perfectly level,

otherwise the seal of the trap is weakened and sewer gases can

enter.

Sometimes the trap is located on the house sewer just outside of

the foundation wall. In this case, a pit should be built large

enough for a workman to get down to it to clean it out when

necessary.

_A mason's trap_ was formerly used to a considerable extent, but is

very poor practice to use today on modern work. This trap was built

square of brick with a center partition. The brick soon became foul

and the trap would be better termed a small cesspool than a trap.

POINTS TO REMEMBER ABOUT HOUSE TRAPS.--

_First_, should be a running trap.

_Second_, two clean-outs.

_Third_, deep seal, at least 2 inches.

_Fourth_, set level.

_Fifth_, set inside foundation wall.

_Sixth_, accessible at all times.

_Seventh_, same size as house drain.

_Eighth_, fresh air should connect with it.

FRESH-AIR CONNECTIONS

The term "fresh-air inlet" is, as its name implies, an inlet for

fresh air. It is placed directly on the house side of the main

trap. The connections made vary considerably. A few good

connections in common use are explained below.

When the trap is in place, one of the clean-outs can be used for

the fresh air. If this is done, a Y-branch should be placed in the

hub of the clean-out. The Y-branch should be used for the fresh air

and the run should be used for a clean-out.

A Y-fitting can be inserted directly back of the trap and the

branch used for the fresh air. An inverted Y makes a good fitting

to use directly back of the trap. These branches should be taken

off the top of the pipe. The branch taken off for the fresh-air

inlet should not have any waste discharge into it and should not be

used for a drain pipe of any description.

The fresh-air inlet should run as directly as possible into the

outer air, at least 15 feet from any window. The pipes terminate in

a number of different ways, some with a return bend, above the

ground, some with a cowl cap, some with a strainer. When necessary

to run pipe through the sidewalk, a box of brick is made with a

heavy brass strainer fitted level with the sidewalk into which the

pipe runs. If the pipe is run into the box on the side a little up

from the bottom, the possibility of becoming stopped up or filled

up is not great. The fresh-air inlet sometimes terminates above the

roof of the building.

Special care should be given this fresh-air inlet as it supplies

fresh air to the entire system and thus keeps the pipes in a much

better sanitary condition.

Sometimes when the house drain is full of sewage, air is pushed out

of the fresh-air inlet and disagreeable odors are evident. This is

why it should be located as far as possible from any window.

Special care should be taken on the part of the plumber not to

locate the fresh-air inlet nearer than 15 feet to the fresh-air

intake of the heating system.

[Illustration: FIG. 60.--Fresh-air inlet.]

When the pipe passes through the foundation wall, the same care

should be exercised as with other pipes. That is, if the pipe is 4

inches, a sleeve 6 inches should be cut in the wall for the 4-inch

pipe to pass through.

POINTS TO REMEMBER ABOUT FRESH AIR.--

_First_, never should be smaller than 4 inches.

_Second_, one size smaller than trap.

_Third_, location, directly back of trap.

_Fourth_, leads to outer air.

_Fifth_, keep away from windows and intake of heating system.

_Sixth_, always have end of pipe covered with strainer, cowl, or

return bend.

_Seventh_, make as few bends as possible.

_Eighth_, supplies fresh air to system.

DRUM TRAP

The use of the drum trap is very handy to the plumber as well as

efficient and practicable when installed. The trap can be purchased

without any outlets or inlets, so the plumber can put them in

according to the necessary measurements. The making of these traps

with lead is explained in the chapter on Wiping Joints. The open

end has a brass clean-out screw on it. When this clean-out screw

comes below the floor, another brass screw cap and flange is

screwed on the floor above the trap so that the clean-out screw in

the trap is easily accessible.

[Illustration: FIG. 61.--Drum trap.]

These drum traps are called bath traps as they are used mostly on

bath wastes. They should never be installed with the clean-out

exposed to the sewer side of the trap. In the best practice, heavy

brass drum traps are used.

NON-SYPHONING TRAP

[Illustration: FIG. 62.--Flask trap.]

[Illustration: FIG. 63.--Clean-sweep trap.]

After years of experimenting to produce a trap that would not

syphon without venting, we find in use today a large variety of

non-syphoning traps. Traps that will hold their seal against all

practical forms of syphonic action, or other threatening features,

have been made and used and serve the purpose for which they are

intended. Various means to prevent the breaking of the seal of

these traps are employed. While some depend on a ball or other kind

of valve, others rely on partitions and deflections of various

kinds. All of these perform the functions for which they are

designed, yet the devices employed offer an excellent obstruction

for the free passage of waste; therefore, in time, these traps

become inoperative. It should be borne in mind that any traps with

a mechanical seal or an inside partition are not considered

sanitary. The inside partition might wear out or be destroyed and

thus break the seal without the knowledge of anyone and allow sewer

gas to enter the room. The mechanical device may also be displaced

or destroyed, leaving the trap without a seal. If the trap were

cleaned out often or examined occasionally, these traps could be

used with a greater degree of safety. Some of the forms of

non-syphon traps in common use are:

The _Flask Trap_, Fig. 62. This trap gets its name from its

shape. There is an inside wall upon which the seal depends.

This trap is like the bag trap, only the two inside walls of

the pipe are combined into one. This wall should be of heavy

cast brass, free from sand holes.

_Clean Sweep Trap_, Fig. 63. Some clean sweep traps are

dependent upon an inside wall for their seals. They are made

of 1/2-S, 3/4-S, and full S.

[Illustration: FIG. 64.--Mechanical-seal trap.]

[Illustration: FIG. 65.--Standard "S" trap.]

[Illustration: FIG. 66.--Bag trap.]

_Sure Seal Trap._ The sure seal trap is designed to be

non-syphoning. This trap also has an interior waterway. If

this waterway leaks, the trap is unfit for use. If these traps

are made as shown in the second sketch with the way inside of

a larger pipe, it can be detected if the interior wall leaks.

_Centrifugal Trap._ The centrifugal trap is made similar to

the clean sweep, except that the wall of the inlet pipe is

entirely separate from the body of the trap. The inlet enters

the body of the trap on a tangent, thus making the trap

self-scouring which is a good feature.