TEST OF A WROUGHT IRON DOUBLE TRACK FLOOR BEAM.[1]

By ALFRED P. BOLLER, Mem. Am. Soc. C. E.

Testing to rupture actual bridge members is always a matter of great

scientific interest, and while the record is quite extensive in eye bars,

posts, or small parts, the great cost, time, and inconvenience of handling

heavy girders has prevented experiment in that direction. In fact, the

writer is unaware of any experiment upon compound riveted beams on a large

scale, as actually used, until the experiment recorded below was made

under his supervision. The beam was an exact duplicate of those in use on

a bridge, about which more or less controversy had arisen as to their

practical safety, and the test was made under, as near as possible, actual

conditions of attachment and loading. The annexed drawing shows the form

and proportion of the beam and connection with the posts, together with

the position of the track stringers. The actual static loads to which the

beam could be subjected by the heaviest engines in use on the road, with

weight of floor, is 40,000 lb. at each stringer bearing, the strains

computed therefrom being as follows: Flange strains at _m_, 3,800 lb. per

square inch; at _a_, 5,700 lb. per square inch; at _b_, 6,400 lb. per

square inch. Shear strains in web, between _a_ and _b_, 2,600 lb. per

square inch. Shear strains in web, between _a_ and end, 8,000 lb. per

square inch at least section, or where the web is 2 feet 4 inches deep, or

42 diameters between angle iron.

[1] Abstract of a paper read before the American Society of Civil

Engineers, November 16, 1887.

[Illustration]

[Illustration]

_Rivets._--All rivets 7/8 inch diameter, or 15/26 inch when driven to fill

holes; area of section, 0.6 square inch; bearing area, diameter x 3/8

plate = 0.35 square inch, and for 1/2 inch plate 0.47 square inch. Post

attachment, considering all the twenty-six rivets doing duty, yields

rivet strain as follows: In shear, single 5,000 lb. per square inch: and

bearing area--1/2 inch plate--6,600 lb. per square inch.

_Connection of 3/8 Web to Flange Angles._--Taking the forty rivets between

ends of girder and second stringer, the horizontal strain difference is

162,000 lb., the rivets being strained 3,400 lb. per square inch double

shear, and 11,600 lb. per square inch bearing area. Taking distance from

ends to first stringer, the horizontal strain difference is 105,000 lb.,

yielding on twenty rivets 4,200 lb. per square inch double shear, and

15,000 lb. per square inch bearing area. Taking a short distance of 2 feet

from ends, the horizontal strain is 70,000 lb. on ten rivets, giving 5,800

lb. per square inch double shear, and 20,000 lb. per square inch bearing

area. In these girders the weakness feared was in the end flange riveting

and shear in end web, and caused the test recorded below. The test was

recently made at the works of the Keystone Bridge Company, by means of

hydraulic power applied at stringer points. Convenience made it necessary

to make the test with the beam blocked up horizontal on the ground, so

that the weight of the beam is necessarily neglected. The beam was

connected with a pair of posts, precisely as in the actual structure,

between which an additional girder was framed as a reaction base for the

rams. The annexed diagram shows the general arrangements. The hydraulic

power was derived from the testing machine plant of the Keystone

establishment, and the deflections measured from a fine wire parallel to

the lower flange, and about 3 inches therefrom. The diameter of the ram

was 10 inches; area 78.54 inches. The record was as follows:

Gauge Load on Deflections. Total

reading. each ram. _b_ _b_' load.

lb. in. in. lb.

565 44,375 1/8 1/8 177,500

1130 88,750 5/16 5/16 355,000

1412 110,900 3/8 3/8 443,600

No permanent set in above

1695 133,125 uncertain. -- -- 532,500

Permanent set scant 1/32 inch.

1980 155,500 not recorded. -- -- 622,000

Permanent set 5/32 inch.

2080 Failure commenced. -- -- 653,500

Failure commenced through giving way of angle irons, beginning in a fine

seam in the first bend of the lower flange from the end support, the seam

being along the root of the angle, which continual pressure tore apart

across the angle as shown, when the web commenced to tear like a sheet of

paper, in direction and manner as exhibited on plate herewith--from

photograph. From some cause not apparent the deflections were not similar

at the symmetrical end rams, _a_, the point where the web failed--left

side--being sharply deflected. While the angles showed root fracture at

the opposite point, the web did not fail or show indications of so doing,

the deflection being on an easy curve. With the extreme yielding of the

lower flange angles, the angle brackets connecting girder with posts

commenced to go, tearing likewise along the root, and stripping the heads

from the extreme upper rivets as shown. The internal diaphragm connecting

the channel sides of the posts was unaffected. The rivets connecting the

ruptured flange with web appeared as perfect as when driven, and no

indication was disclosed, as far as it was possible to tell, of the holes

in the web elongating or any upsetting of bearing surface. There is no

telling what the web and rivets would have borne had not the solid angle

irons given way at the first bend. It is to be noted that flange plate

with leg of angle attached thereto was intact, showing no indication of

rupture.

_Discussion._--Taking that stage of the experiment when a permanent set

was first noted--viz., 1/32 inch--the recorded load was 532,500 lb., or as

near as may be 3-1/3 times the basis on which the calculations in the

first part of this paper were made--40,000 lb. on each stringer, or

160,000 lb. total. Applying this ratio to the preceding computations, the

iron would be apparently strained as follows:

{ _m_ 3,800 x 3-1/3 = 12,600 lb. per square inch (psi).

Flanges at { _a_ 5,700 x 3-1/3 = 19,000 psi.

{ _b_ 6,400 x 3-1/3 = 21,200 psi.

Web. { Between _a_ and _b_, 2,600 x 3-1/3 = 8,700 lb. per square inch.

{ At least section, 8,000 x 3-1/3 = 26,600 psi.

{ Post attachment:

{ Bearing area, 6,600 x 3-1/3 = 22,000 lb. per square inch.

{ Single shear, 5,000 x 3-1/3 = 16,600 psi.

Rivets. { Web and flange connections, end rivets:

{ Bearing area, 20,000 x 3-1/3 = 66,600 psi.

{ Double shear, 5,800 x 3-1/3 = 19,300 psi.

When failure in angles was first noted, the recorded load was 653,500 lb.,

or slightly more than four times the computed basis of load, which would

increase the above strains about one-fifth, giving a calculated flange

strain when angle failed of some 15,000 lb. per square inch, and bearing

area strain on end flange and web rivets about 80,000 lb. per square inch,

neither of which could possibly be true, or the web would have torn out

from the rivets, and the flanges be perfectly sound, well within elastic

limits, although in the last case it is to be noted that the horizontal

table of the flange was perfectly sound, the flange failure commencing

primarily with a long split along the weld of the angle iron root,

throwing the whole flange duty upon the vertical legs of the angle iron,

when a rupture strain was quickly reached. Had the angles been rolled from

a solid ingot, or on the German method of developing from a flat instead

of from the ordinary welded pile, the strength of this beam would have

been largely increased. The prime weakness in this beam was due,

therefore, to the mode of manufacturing the angle irons, which were weak

along the weld at the root. This was also shown in the end bracket angles

uniting the beam to the posts. The writer deduces from this experiment

that a plate web is an exceedingly stiff member, much stiffer than is

commonly supposed; that the customary method of proportioning

rivets--viz., the horizontal component between any two given points

divided by allowable bearing pressure per square inch equals number of

rivets required--is not true, and that the friction due to power riveting

has enormous value. This beam was reported to the company interested as

practically safe by the writer, on general considerations, before the

experiment was made, and the opinion reaffirmed after the experiment.

* * * * *