Section X DEMOLITION TO PREVENT ENEMY USE

46. DESTRUCTION PROCEDURE.

If circumstances should force abandonment of chemical warfare materiel

in the field, it is destroyed or rendered useless to prevent its use or

study by the enemy. The following methods are recommended:

_a. Flame thrower._ One or more small-arms bullets through the fuel

tanks will prevent any immediate use of the flame thrower. Additional

rounds may be put through the pressure tank. If the pressure tank is

charged, the pressure-tank valve should be opened for a few seconds,

thus permitting the contents to dissipate. This is necessary if rounds

are to be fired point-blank. The gun may be rendered useless by bending

it over a hard object. A sledge or ax will demolish valves and tubes. A

fragmentation grenade will also achieve demolition.

_b. Filling and charging apparatus._ The flexible tubing, gages, and

valves may be destroyed by blows with an ax, sledge, or other heavy

instrument. The large pressure cylinders are rendered useless by

releasing the contents and then destroying the valves by blows with an

ax or sledge. Cylinders can be stacked like cordwood in groups of five

and demolished by the detonation of four 1/2-pound blocks (2 pounds) of

TNT in their midst. The air compressor may be destroyed by a similar

procedure.

_c. Fuel._ Burn.

_d. Mixing apparatus._ Containers and filling lines may be rendered

useless by ax or sledge blows, or by small-arms fire.

_e. Thickener._ Cans of thickener should be broken open. Contents

should be thrown into a fire or into a body of water.

_f. Ignition cylinders._ Burn to destroy. Personnel should stay

several yards from the fire because the cylinders ignite with a slight

detonation.

PART THREE

MAINTENANCE INSTRUCTIONS

Portable Flame Thrower M2-2 · 第 10 / 19 章