EXHAUST FANS.

First on the list of power consumers is the exhaust fan, taking it in

average use. There are, however, circumstances under which its use

will be limited to as low as 70 or 75 per cent. of its contract hours

of service. As, for instance, in a dining room it may be cut out

except during meal hours, or entirely cut out on cool days. In places

of this description, however, its contract use is usually limited to

five or six months in the year, and other than electric power is, by

circumstances of first cost and inconvenience, but a feeble

competitor.

The first four applications on the accompanying list, viz., exhaust

fans, blowers, ceiling fans, and fan outfits, are all more or less

subject to the foregoing conditions, and therefore currents supplied

to motors for these purposes command the maximum price per horse

power. One important feature in the installation of ceiling fans is

the countershafting to the motor. In one recent case we had a

complaint from a customer that the half horse power motor sent him

would not drive the ceiling fans, and that the motor must be

defective, and should he return it for repairs. We immediately sent a

representative to find out the difficulty, which was found, as is

usual in such cases, in the countershafting, or rather the want of it.

The 3 in. pulley on the motor was connected to a 6 in. pulley on the

line shafting. The rated speed of the motor was 2,000 revolutions, and

had it been able to develop this speed, would have driven the line

shaft 1,000 revolutions and the fans a relative speed. To accomplish

this would probably require a motor of 3 or 4 H. P. The line shafting

driving ceiling fans usually runs about 75 revolutions. To give this

speed on the line shaft with a rated speed of 2,000 on the 3 in.

pulley of the motor would require a countershaft with a 24 in. pulley

belted to the motor. On the same countershaft should be a 5 in. pulley

belted to a 15 or 16 in. pulley on the line shaft. Fully three-fourths

of the trouble found in electric motors arises from improper shafting

and belting. The average make of 30 in. exhaust wheel, a ½ H. P. motor

should drive about 400 revolutions. Say, then, the speed of the motor

is 2,000 and the pulley 3 in., it would require a 15 in. pulley on the

fan to do the work. A 36 in. wheel requires 1 H. P. to develop the

same speed. If the motor speed is 1,800, the pulley 4 in., it would

require an 18 in. pulley on the fan to do the work. These are the most

popular sizes of exhaust wheels.

The next application on the list, open tank elevator pumps, commands

the highest price for current per H. P. in the motor of any elevator

application. The methods of operating the open tank hydraulic

elevators in question are undoubtedly familiar to you all. Instead of

the usual steam pump, a power pump of some approved design is

substituted, and connected to the motor by suitable countershafting to

give the required revolutions at the pump. The regulation of the motor

in this case should be controlled by the position of water in the

lower tank, as in the case of the steam pump. And in this connection

let me suggest the necessity of great care, both in installation and

insulation.

On all installations in basements and cellars or elsewhere where there

is the slightest tendency to dampness, raise the motor off the floor

on a suitable frame or stand and build around it on all sides of

possible approach a low platform, using glass insulators as legs or

standards to support it. So arrange this that the motor or its

connections cannot be reached except when standing on this insulated

platform, and the liability to a shock will be reduced to the

difference of potential between the terminals of the machine. To

return to the subject. Let us take for an illustration an elevator

using 120 gallons of water per trip and consuming one minute in making

its entire up trip or about two per round trip. The lower tank or

water supply is on a level with the pump. The upper tank is 70 ft.

above the pump, and in the piping to the upper tank are five elbows.

For each elbow add 2 ft. to the elevation, or an approximate total

elevation of 80 ft. × 120 gallons gives us 9,600 foot gallons. This

amount would be required every two minutes if the elevator was in

absolutely constant operation, or 4,800 foot gallons per minute × 8½

gives us 40,800 foot pounds. This we must at least double to allow for

friction in pump shafting, etc., making 81,600 foot pounds, or about

2½ H. P., say 3 required in the motor.

This class of elevator is confined almost entirely to passenger use.

Therefore the service required of the motor is much more constant and

the margin between the H. P. hours contracted for and the H. P. hours

of actual service much smaller than in any other elevator use,

excepting possibly the services in connection with pressure tank

elevators in the more popular office buildings. In this case we have a

maximum average use of 80, and instances such as the hotels, small

office buildings, etc., where the service will not exceed 60 of the

contract H. P. hours. In order, however, that the electric light

company shall derive the greatest benefit from this inconstant

service, the installation and wiring should be the best, and only the

most approved and economical apparatus employed.

The next application on our list, pressure tank pumps in connection

with elevators, represents a somewhat smaller percentage of H. P.

hours of actual service in the motor as compared with the possible H.

P. hours than in the case of an open tank pump. In case of the

pressure tank the water reserve is usually limited, and the motor

therefore must be equal to the continuous operation of the elevator at

maximum load. Taking this fact into consideration, and the

circumstances of elevator use being about the same in this case as in

the case of the open tank elevator, we have a greater ratio of

difference between the possible or contract H. P. hours in the motor

and the H. P. hours of actual service, the maximum average use being

about 70 per cent. to 75 per cent. and the minimum as low as 35 per

cent. to 40 per cent., depending, of course, on the character of

building in which the elevator is employed or the character of

service. In calculating the size of motor required on an elevator of

this description, a very convenient fact to remember is that every

pound of pressure per square inch is equivalent to lifting water about

23 ft., or about 230 ft. per 100 pounds pressure, By reducing the

required pressure to a relative lift in feet, and knowing the amount

of water required by the elevator per minute, the motor calculation

becomes the same as in case of the open tank elevator, the same

allowances being made for friction, etc., as in the first case. The

regulation of the motor in this case should be accomplished by the

conditions of pressure in the pressure tank, as is the case with a

steam pump employed in this service.

The next application of importance on the list is sewing machines. In

the tests I have been able to make on this class of work I have

obtained some singular results. One item of importance is the fact

that the single thread machines, which are lightest running, consume

the most power in operating. Paradoxical as this may seem, it is

easily explained. As a rule this class of machine is used on light

work, such as shirts, ladies' underwear, etc., and operated at a

higher speed than any other class of machine. At equal speed the volts

consumed on a single thread machine as compared with a shuttle machine

is about as 2 to 3. In average commercial use, however, the positions

are reversed, and the ratio of volts consumed in the single thread as

compared with the shuttle machine is about as 5 to 3. To double the

speed on a sewing machine requires about 2½ times the power. The

difference in volts consumed on the different makes of sewing machines

is so small that we may disregard it entirely, as well as the

character of work done by the machine, for the heavier the work the

slower the speed, and more frequent and longer stops on the machine,

thus keeping the average volts per operator about constant in all

cases. This leaves the speed in stitches per minute at the sewing

machine the factor from which we must calculate the power required in

a sewing machine plant. To illustrate this I will give you the record

of two cases which are about the average. Case No. 1 is a shop in

which are 30 sewing machines connected to a 2 H. P. motor. At the time

tests were made there were but twenty operators at work, leaving ten

idle machines, the entire shafting, however, being in operation. The

class of goods manufactured in this shop is a cheap grade of cotton

and wool pants, rather heavy goods to sew. A volt meter across the

terminals of the motor gave the following readings with the current at

9 amperes: Minimum 90 volts, maximum 148 volts, average 119, which

gives us a minimum average per operator of 4.5 volts and a maximum

average of 7.4 volts, or a general average of 5.9 volts per operator.

This motor was driving the shafting for 30 machines, and as the

average operators employed the year round will not exceed 75 per cent.

of the shop capacity, it will, I think, be entirely fair to estimate

the average volts per machine rather than per operator, as the user of

the motor has contracted for power sufficient to drive his entire

plant. In this case, then, we have a minimum average of 3 volts per

machine and a maximum of 4.9 volts, or a general average of say 4

volts per machine. A 2 horse motor of 82 per cent. efficiency with 9

amperes of current will require about 200 volts to develop 2 actual H.

P. Two hundred volts therefore is what the electric light company

contract to deliver, while, in reality, they deliver only 129 volts or

60 percent., or a minimum average of 90 volts or 45 per cent. of the

power contracted for. These machines were making about 1,200 stitches

per minute--an average of 4 volts per 100 stitches.

Case No. 2 is a shop in which there are 32 machines, running about

1,200 stitches, each being supplied with an individual motor of 1/8 H.

P. capacity, and the class of goods manufactured being men's summer

clothing, such as white duck vests, flannel coats and vests, etc., the

duck from which these vests are made being about as hard work on a

sewing machine as can be found. In this shop were 24 operators at

work. The maximum volts in this case were 116 and the minimum 40, or

general average of but 78 volts, or about 2½ volts per machine with 4

more operators than in the first case, in which we had an average of

119 volts. This shop has been paying the electric light company $32

per month for more than a year, which is the price the company charge

for current for a 4 H. P. motor which approximates 400 volts, the

company contracts to deliver. This gives us a minimum average use of

but 10 per cent. and a maximum of 29 per cent. with a general average

of 19½ per cent. In other words, the company is saving in this shop

the price of a 1/8 H. P. motor each month, besides making a profit on

the volts actually delivered. On a contract for three years the

electric light company would be money in pocket if they would present

the customer with 30 small motors, charging him $1 per month per motor

for current, rather than let him buy a 2 H. P. motor to operate the

same machines with the necessary shafting at a charge of $18 per month

for current. Taking this average in case No. 2 of 2½ volts per

machine, from a 50 light machine, we could run not less than 900

sewing machines, or about 18 to the arc lamp. At $1 per month per

machine an income of $900 per month would be derived from a 50 light

machine without any lamp expenses, such as carbons, repairs on lamps,

globes, etc. On the average, in case No. 1, of 4 volts per machine, we

could operate but about 562, say 600 machines. Divided up in shops of

30 machines and a 2 H. P. motor to each shop, we would have 20 two H.

P. motors. At a charge of $18 per month each, we would have an earning

capacity of but $360 per month from the same 50 light machine.

This is but one page from the thus far unwritten history of the much

maligned small motor. Still the question is frequently asked, "Can we

sell current for $1 per month for a small motor driving a sewing

machine and make a profit?" As a matter of fact, 50 cents per month

for small motors driving sewing machines yields a better profit to the

company supplying the current than $10 per month per H. P. in large

motors to drive the same machines, besides the immense advantage which

the small motors possess of keeping the circuit in much better

balance, the fluctuations due to the stopping and starting of large

motors being at times a serious matter. One electric light company,

making rather a specialty of these small machines, rent the motor and

supply the current for $1.25 per month per sewing machine, and report

that at this price the motor pays them a better percentage of profit

than their lamps. This company have some 200 small motors on their

circuits.

A more striking illustration of the advantages to the electric light

company in the subdivision of power into the smallest possible units

it would be hard to find. There is a difference in efficiency of from

15 to 20 per cent. in these two sizes of motors, but this difference

is fully lost to the large motor in driving the shafting, and the

small motor still has the advantage of being out of circuit entirely

when the machine it is driving is stopped. There is scarcely a

manufacturing industry which does not possess its busy and dull

seasons. This means that in no industry will over 75 per cent. of the

machines or machinery employed be in average operation. The entire

shafting in the shops must be kept in operation the entire year, often

for less than 50 per cent. of the machinery. Subdivide these same

shops into as many small units as possible, and the current necessary

to operate the shafting for this idle machinery will be saved, besides

the saving from frequent stops while the machinery is in active use.

To return again to the list, the next two applications, picture frame

manufacturers and moulding manufacturers, are very similar. Their busy

seasons, as a rule, are in the spring and fall, and also follow

closely any activity in house building. In the case of the larger

manufacturers in this line, a maximum average of 75 per cent. will

possibly be reached, but probably never exceeded. In the case,

however, of the picture dealer who has a small shop in which he makes

picture frames and mouldings to order the actual service of the motor

will fall as low as 25 per cent. or 30 per cent. of its contract

hours, one case in our experience the actual service having reached

this low average. A fair general average in this class of works would

be about 60 per cent.

The next application, nickel and silver platers and buffers, are good

contract customers as a rule; one case in our experience showing but

an average use of 20 per cent. of the contract horse power hours.

This, however, is probably an exceptional case, and, as near as we can

estimate on this class of work, the actual motor service will not

exceed in any case 60 per cent. of the contract hours; a fair average

being probably 45 or 50 per cent.

The next two applications, printing presses on news and job work, are

probably met with more frequently than any other. On exclusively news

work, the instances where the motor is in service more than 3 or 4

hours is rare. It is, however, usual in news offices to find two or

more job presses. If the newspaper printed happens to be a morning

paper, the hours of news work are usually between 12 midnight and 4

o'clock in the morning, the job work being done through the day. I

have in mind a case of this description. In the shop is one cylinder

press and three job presses connected to a 2 H. P. motor. This motor

is on an incandescent circuit of 110 volts. To develop its rated power

at 110 volts would require about 16 amperes in the motor. An ampere

motor in series with the motor while running off the morning paper

with only the cylinder press in operation stood at 12 amperes. For 3

hours this load was practically constant, when it was thrown off

entirely. This gave on the night service but 30 per cent. of the

contract hours. This motor required 5 amperes to drive the shafting,

and but 8 amperes or one H. P. to drive the three job presses with the

cylinder press off. Here then is but a 50 per cent. use if the presses

be used constantly; there are, however, many days when they are

comparatively idle, 30 to 40 per cent., therefore, is a very safe

estimate of the maximum use of this motor on the day circuit, or, had

the motor been a 1 H. P., which would have been sufficient to drive

the job presses, the use would be 60 to 80 per cent. of the contract

hours, probably not above 60 per cent. All printing offices will

probably come within this range, unless the motor be larger than is

necessary to do the work.

Machine shops doing principally lathe work as a matter of course use a

larger percentage of their contracted power than shops doing lathe and

bench work with the same hands. In no case will the service of the

motor exceed 65 or 70 per cent. of its contract use, for machine

shops, like sewing machine shops, will never average over 75 per cent.

of the shop capacity for operators the year round. The average,

especially in the case of a shop doing much bench work, will fall as

low as 40 per cent.

The driving of laundry machinery, which is our next application,

usually proves a profitable contract, according to reports. This fact

arises from the intermittent use of the machinery. The heaviest

service on motor will probably be found during the early part of each

week, with a general falling off in work during the summer months,

while the patrons of the laundry are away at the sea-shore or in the

mountains. In this application, therefore, a 75 per cent. service

would probably be an exception, with, probably, many instances where

the service would fall below 50 per cent.

The next application, model and pattern makers, are small users of

power, as their occupation requires a large proportion of hand work.

50 per cent. service in the motor will be found a fair average maximum

use, with instances as low as 20 or 25 per cent.

The next application, direct power or belt elevators, is another

application frequently met. The average service in the motor is also

much smaller than in any other elevator application. Let us suppose a

case of the familiar grip connected to the ordinary hand hoist, with a

lifting capacity of 2,000 pounds. In this case the motor is in use

only going up, and the usual brake is used in coming down. Connected

to this elevator, in the loft of the building, we have a 5 H. P. motor

wired to a cut-out on the ground floor. We will call the lift 45 feet

and the time consumed per trip 1 minute. We will allow 60 full trips

of the elevator at full load, at 2,000 lb. per trip, each day. This

would approximate 10 car loads of merchandise handled by the elevator,

which is certainly above the average. This motor, we will say, is on a

ten hour day circuit. Its possible horse power hours, therefore, would

be 5 H. P. for 10 hours, or 50 H. P. hours per day. 60 trips of 1

minute each gives us exactly 1 hour's service of the full 5 H. P. or 5

H. P. hours. To drive the shafting only while the elevator is coming

down or idle would require about 150 volts or 1½ H. P., and if this

was in constant operation the balance of the day, 9 hours, its total

use on shafting would be 13½ H. P. hours, which, added to the 5 H. P.

hours, gives us a grand total of 18½ H. P. hours, or 37 per cent. of

the contract hours. If, however, the user of the motor avails himself

of the cut-out box, and cuts the current out when the motor is not in

use, the average use would drop to 20 or 25 per cent., instead of 37

per cent. In the case of a direct power passenger elevator, the use

might possibly run up to 60 per cent., but this would be exceptional.

Coffee mills will average from 40 to 60 per cent. of their contract

hours, manufacturing jewelers about the same, while retail jewelers

will run as low as 25 per cent. Ice cream freezers will not average

over 25 per cent., but as the contract season in this case is usually

short, they should be rated at least a 50 per cent. basis, except

possibly in cases where the customer pays the cost of installation and

wiring, which is usual in these cases.

A dentist is one of the smallest of power users, so small, in fact,

that if every one in a city were connected with a circuit, the load

from this cause would never be felt. We will, however, put them down

at from 10 to 20 per cent.

The optician uses a motor to turn his grind stones, and its use in

this case will average from 20 to 30 per cent.

The last application on the list--church organs--uses only from 10 to

20 per cent. of the contract service.

These are, of course, but few of the very many applications of the

electric motor, and if, as I trust, the possible subsequent discussion

of this general plan may establish a basis for rating motor

applications, not only will the objects of this paper be obtained, but

a question of considerable annoyance now existing between the motor

man and the electric light or power company will be solved.

In conclusion, Mr. Chairman, I beg to suggest that the supply and

rates of charge for electric power have become of sufficient

importance to this association to be represented by a permanent

committee, whose duty it should be to obtain from the different

members of the association, as far as possible, their experience in

the supply of power in such manner and form as shall be deemed by the

committee best suited to the wants of this association.

* * * * *