THAWING

The importance of carefully controlled cooling and storage has been

emphasized in the foregoing sections. The need for controlling thawing

rates and the temperature of thawing was not clearly defined in the

early work on freezing bull semen. The British used a thawing

temperature of 40 deg. C., which was satisfactory. If there is a need to

hold the semen for a time after thawing, then a lower thawing

temperature might be more desirable so that cooling again will not be

necessary.

=Comparison of thawing temperatures of 5 deg. C. and 38 deg. C.= The effects of

thawing at temperatures of 38 deg. (body temperature) and 5 deg. C.

(refrigerator temperature) were investigated. The first trial involved

thawing as rapidly as possible by dropping glass ampules of frozen semen

into water baths at the two temperatures. The frozen semen samples

contained glycerol levels of 4, 6, 8, and 10 percent. The mean

percentages of motile sperm found after thawing thirteen diluted semen

samples treated in this manner are shown in Figure 6.

[Illustration: Effect of glycerol percentage and thawing temperature on

sperm motility after freezing and thawing (Fig. 6)]

The 5 deg. C. thawing temperature resulted in a higher percentage of sperm

survival at all the glycerol levels than 38 deg. C., with the difference in

favor of 5 deg. C. becoming greater as the glycerol level increased. The

reason for the interaction between glycerol level and thawing

temperature is not known. It may be that the presence of the higher

levels of glycerol at 38 deg. C. brought about harmful metabolic activity.

The difference in survival of sperm in semen thawed at 5 deg. C. and at 38 deg.

C. continued during storage at 5 deg. C. (Table 15). It was also evident

that the interaction between glycerol level and thawing temperature

continued during storage (Fig. 7).

[Illustration: Effect of thawing temperature on sperm motility during

storage at 5 deg. C. following freezing and thawing (Fig. 7)]

Table 15.--Effect of Glycerol Level, Thawing Temperature, and Storage at

5 deg. C. After Thawing on Sperm Motility (Average of 13 ejaculates)

=====================================================================

Thawing Glycerol Sperm motility (percent)

temperature level -------------------------------------------

( deg. C.) (percent) Post- After storage at 5 deg. C.

thawing ---------------------- Average

1 day 3 days

---------------------------------------------------------------------

38 4 28.5 17.3 5.1 17.0

6 31.5 22.4 9.2 21.1

8 33.1 15.0 4.6 17.6

10 19.5 3.6 0.8 8.0

Average 28.2 14.6 4.9 12.2

5 4 29.2 21.7 19.8 23.9

6 37.7 33.8 23.5 31.7

8 41.5 33.1 17.3 30.6

10 33.1 18.5 6.0 19.2

Average 35.4 26.8 16.6 20.6

---------------------------------------------------------------------

It is obvious that motility falls off rapidly after the semen is thawed.

In a field trial in which the initial intent was to test the effect of

glycerol levels on fertility of frozen semen, the semen was thawed in

the morning and used during the same day. Survival of the sperm with 4

percent glycerol was so poor that only a few breedings were made with

these samples. Even at 7 and 10 percent, the fertility results were much

lower than with semen that had not been subjected to freezing. At that

time it was felt that thawing the samples and using them throughout the

day may have caused the low fertility results. Since then, a

large-scale experiment by Cornell University investigators, in

cooperation with the New York Artificial Breeders' Cooperative, has

shown definitely that thawing should be delayed until a few minutes

prior to breeding.[11] If the semen is used immediately, a thawing

temperature of either 5 deg. or 38 deg. C. appears to be suitable. However,

there is less danger of cold shock due to recooling if 5 deg. C is used.

=Thawing rate in plastic and in glass.= Glass ampules transmit cold or

heat more readily than plastic ones. The temperature rise is rapid in

both glass and plastic when samples are taken from the storage box at

-79 deg. C. and placed in water at 5 deg. C. However, complete thawing occurs

more rapidly in glass than in plastic ampules. The changes in

temperature that occurred when glass and plastic ampules were thawed in

a water bath at 5 deg. C. are shown in Figure 8. The initial temperature

rise for the first minute or two was about the same, then the rate of

warming in the plastic slowed and actual melting of the frozen sample

occurred a little over a minute later in the plastic than it did in the

glass. Both were thawed in less than four minutes.

[Illustration: Warming rates of diluted semen samples in plastic vials

and in glass ampules (Fig. 8)]

Preservation of Bull Semen at Sub-Zero Temperatures · 第 18 / 22 题