CHAPTER IV

SUB-SURFACE IRRIGATION

The disposal of sewage by the method of sub-surface irrigation,

sometimes known as the Waring system, consists in its distribution by

means of open jointed tiling over a comparatively large area of soil and

at a depth of a few inches beneath the ground surface. The sewage should

first be passed through settling tanks to remove as much as practicable

of the suspended matters contained in it, as explained in the chapter on

settling tanks. The partially clarified effluent from the settling tank

should then be collected in a dosing chamber, or separate compartment of

the settling tank, and discharged intermittently, preferably by means of

a siphon, into the sub-surface irrigation system. This intermittency of

discharge of accumulated quantities of effluent is necessary for an even

distribution of the effluent throughout the entire system of sub-surface

tiling, and for a continuous and successful operation of the system as a

whole. It has been found necessary, also, to alternate the discharge of

effluent from the dosing or siphon chamber over different portions of

the irrigation area. One siphon is all that is necessary to install in

the siphon chamber for sub-surface irrigation systems, and if the

settling tank has two compartments, as shown in Fig. 3, Chapter II, the

single siphon would be placed in the centre of the chamber.

The principle involved in this method of sewage purification is that of

any general method of sewage reduction in whatever form carried on,

namely, its oxidation or nitrification. This oxidation, or breaking down

of the organic matter in the sewage, is accomplished in this case, as in

the case of intermittent sand filters, contact beds, and sprinkling

filters, through the agency of bacterial action.

Householders have long been familiar with the fact that although solids

contained in sewage may have been discharged for long periods of time

into a cesspool, the latter, if located in dry, porous soil, did not

seem to become filled with the solid residue. This is due to the

liquefaction of the solid matter in the sewage after its discharge into

the cesspool, and to the seepage and bacterial reduction of the liquid

matter in the surrounding soil. To replace the cesspool and eliminate

the insanitary conditions which, in most instances, result from its use,

other methods have been devised which utilize the agencies of nature to

the best advantage. Thus the sedimentation and, in some cases, the

liquefaction of the solid matters in sewage are carried on in specially

designed settling tanks which are easily cleaned and which provide for

greater efficiency in settling out suspended matters than the cesspool.

Similarly, the filtration of liquids from cesspools through the soil is

replaced by the scientific method of sub-surface irrigation, which is

much more efficient in three distinct ways: (1) the limited seepage area

represented by the walls of the cesspool is increased many times by

distributing the effluent from the settling tank over a large area of

soil in a system of sub-surface tiling; (2) the bacterial reduction is

more effective, since it has been found that the bacterial action

necessary to purify sewage takes place in the upper layers of the soil

and is almost absent at depths of five feet or more; (3) the soil is

given an opportunity to rest and to dry out by alternately using

different portions of the sub-surface irrigation system. In the cesspool

the seepage of the effluent and whatever bacterial action takes place in

the surrounding soil must go on continuously, which often results in

clogging of the soil and overflowing of the cesspool.

The purification and final disposition of sewage by means of sub-surface

irrigation is the method best adapted to the single residence, and

oftentimes to the hotel or institution, if soil conditions are favorable

and proper area is available. This system requires less oversight in its

operation than the various forms of artificial filters. Furthermore, the

sewage is entirely hidden from sight after it leaves the settling tank,

and this is usually desirable near private residences and on the grounds

of country homes, country clubs, and summer hotels. Also, where the

sewage must be treated in close proximity to a residence or hotel or at

a point on the windward side of a residence, this method, more

effectually than any other, precludes the possibility of a nuisance

resulting from the operation carried on, since the settling-tank

effluent is at no point exposed directly to the air. Furthermore, its

cost is less than that of other works for final treatment of sewage,

and, finally, the system is more easily installed.

The method is in reality modified broad irrigation, but the sub-surface

irrigation field can be utilized much more effectively and with

considerably less attention than a broad irrigation area, and, as noted

above, is less liable to be the cause of a nuisance or to be the means

of spreading infectious disease through the agencies of flies and other

insects.

If an area of sandy soil is available on which to locate the sub-surface

irrigation field, if the settling tank and siphon chamber have been

correctly built, and if the sub-surface tiling system has been properly

laid, the success of the system is well assured. On the other hand,

failure is certain if either broad irrigation or sub-surface irrigation

methods of sewage disposal are attempted on stiff, impervious clay

soils. Between the ranges of porosity of soil represented by these

limits there are many soils in which sewage may be successfully disposed

of by sub-surface irrigation. A sandy or gravelly loam will, without

question, successfully care for sewage effluent when such effluent is

properly distributed by sub-surface tiling, and even in a rather heavy

soil the effluent from a settling tank may often be disposed of

satisfactorily by providing for a greater length of sub-surface tiling

per person served by the settling tank than that which would suffice in

the more porous soils. However, if the soil is very heavy so that

surface water does not readily seep away, or if the ground-water level

is within two or three feet of the surface, this method is not suitable

and some form of filter, described in the succeeding chapter, should be

used for final treatment of sewage.

When soil conditions and the area available are favorable to this method

and such a system is to be installed, the irrigation area selected

should be at the point where the ground-water level is lowest, and this

will generally be on a plateau or bench at the head of a slope of

ground. The relative elevation of the ground surface should, of course,

be low enough to insure operating head or fall to operate the siphon in

the chamber adjoining the settling tank and to distribute the effluent

by gravity to the sub-surface tiling. If the soil is composed of loose

gravel, or lies over a limestone or shale formation, the location of the

irrigation area should be selected with a view to preventing the

contamination of any wells or springs which may exist on the

premises,—that is, the area should be on lower ground, and as far

removed from wells as is convenient.

As will be explained later, the length of sub-surface tiling necessary

to receive a given quantity of sewage effluent should vary, within

certain limits, with the character and porosity of the soil, thus

requiring larger quantities of effluent to be delivered from the siphon

or dosing chamber in the case of the more compact soils. Also the size

of this chamber should be determined with reference to the number of

sections into which the sub-surface tiling system is divided.

TABLE II

FOR USE IN THE CONSTRUCTION OF SUB-SURFACE IRRIGATION SYSTEMS IN SANDY OR

VERY POROUS SOILS

Dimensions given are for inside measurement.

══════╤═══════╤═══════╤═══════╤═══════╤═══════╤════════╤════════╤════════

Number│ Total │No. of │ Mean │ Mean │ Depth │Diameter│ Dis- │Distance

of │Length │ Sect- │ Width │Length │ of │ of │charging│ from

Per- │ of │ions in│ of │ of │Siphon │ Siphon │Depth or│Roof to

sons │3–inch │ Sub- │Siphon │Siphon │Chamber│ (Inch- │Maximum │ Top of

Served│ Sub- │surface│Chamber│Chamber│ from │ es). │Depth of│ Wall

by │surface│System.│(Feet).│(Feet).│Roof of│ │Effluent│between

Sewer.│Tiling.│ │ │ │ Tank │ │ above │Settling

│ │ │ │ │(Feet).│ │ Lower │Tank and

│ │ │ │ │ │ │Edge of │ Siphon

│ │ │ │ │ │ │ Siphon │Chamber

│ │ │ │ │ │ │ Bell │ (Inch-

│ │ │ │ │ │ │ (Inch- │ es).

│ │ │ │ │ │ │ es). │

──────┼───────┼───────┼───────┼───────┼───────┼────────┼────────┼────────

4│ 140│ 2│2´ │2´ │ 2´ 4˝│ 3˝│ 13˝│ 12˝

8│ 280│ 2│2´ 6˝ │2´ 6˝ │ 2´ 4˝│ 3˝│ 13˝│ 12˝

12│ 420│ 2│2´ 6˝ │4´ │ 2´ 4˝│ 3˝│ 13˝│ 12˝

15│ 525│ 2│3´ 6˝ │4´ │ 2´ 4˝│ 3˝│ 13˝│ 12˝

25│ 875│ 2│3´ │4´ │ 3´ 2˝│ 5˝│ 23˝│ 12˝

35│ 1225│ 2│3´ 8˝ │4´ 6˝ │ 3´ 2˝│ 5˝│ 23˝│ 12˝

50│ 1750│ 2│4´ │6´ │ 3´ 2˝│ 5˝│ 23˝│ 12˝

75│ 2625│ 2│3´ │6´ │ 3´ 2˝│ 5˝│ 23˝│ 16˝

100│ 3500│ 2│4´ │7´ │ 3´ 2˝│ 5˝│ 23˝│ 16˝

125│ 4375│ 3│5´ 6˝ │8´ │ 3´ 2˝│ 5˝│ 23˝│ 16˝

150│ 5250│ 3│7´ │8´ │ 3´ 2˝│ 5˝│ 23˝│ 16˝

175│ 6125│ 3│7´ 6˝ │8´ │ 3´ 9˝│ 6˝│ 30˝│ 16˝

200│ 7000│ 3│8´ │8´ │ 3´ 9˝│ 6˝│ 30˝│ 18˝

──────┴───────┴───────┴───────┴───────┴───────┴────────┴────────┴────────

TABLE III

FOR USE IN THE CONSTRUCTION OF SUB-SURFACE IRRIGATION SYSTEMS IN THE

HEAVIER LOAMS (NOT CLAY OR HARDPAN)

Dimensions given are for inside measurements.

══════╤═══════╤═══════╤═══════╤═══════╤═══════╤════════╤════════╤════════

Number│ Total │No. of │ Mean │ Mean │ Depth │Diameter│ Dis- │Distance

of │Length │ Sect- │ Width │Length │ of │ of │charging│ from

Per- │ of │ions in│ of │ of │Siphon │ Siphon │Depth or│Roof to

sons │3–inch │ Sub- │Siphon │Siphon │Chamber│ (Inch- │Maximum │ Top of

Served│ Sub- │surface│Chamber│Chamber│ from │ es). │Depth of│ Wall

by │surface│System.│(Feet).│(Feet).│Roof of│ │Effluent│between

Sewer.│Tiling.│ │ │ │ Tank │ │ above │Settling

│ │ │ │ │(Feet).│ │ Lower │Tank and

│ │ │ │ │ │ │Edge of │ Siphon

│ │ │ │ │ │ │ Siphon │Chamber

│ │ │ │ │ │ │ Bell │ (Inch-

│ │ │ │ │ │ │ (Inch- │ es).

│ │ │ │ │ │ │ es). │

──────┼───────┼───────┼───────┼───────┼───────┼────────┼────────┼────────

4│ 300│ 2│ 2´ 5˝ │ 3´ │ 2´ 4˝│ 3˝│ 13˝│ 12˝

8│ 600│ 2│ 3´ │ 5´ │ 2´ 4˝│ 3˝│ 13˝│ 12˝

12│ 900│ 2│ 4´ │ 5´ │ 2´ 4˝│ 3˝│ 13˝│ 12˝

15│ 1125│ 2│ 4´ │ 6´ 6˝ │ 2´ 4˝│ 3˝│ 13˝│ 12˝

25│ 1875│ 2│ 4´ │ 6´ │ 3´ 2˝│ 5˝│ 23˝│ 12˝

35│ 2625│ 2│ 4´ │ 4´ 6˝ │ 3´ 2˝│ 5˝│ 23˝│ 16˝

50│ 3750│ 2│ 4´ 6˝ │ 6´ │ 3´ 2˝│ 5˝│ 23˝│ 16˝

75│ 5625│ 2│ 6´ │ 7´ │ 3´ 2˝│ 5˝│ 23˝│ 16˝

100│ 7500│ 2│ 7´ │ 8´ │ 3´ 2˝│ 5˝│ 23˝│ 16˝

125│ 9375│ 3│ 8´ │10´ │ 3´ 9˝│ 6˝│ 30˝│ 20˝

150│ 11250│ 3│ 9´ │12´ │ 3´ 9˝│ 6˝│ 30˝│ 20˝

175│ 13125│ 3│10´ │12´ │ 4´ 2˝│ 8˝│ 35˝│ 20˝

200│ 15000│ 3│11´ │12´ │ 4´ 2˝│ 8˝│ 35˝│ 20˝

──────┴───────┴───────┴───────┴───────┴───────┴────────┴────────┴────────

The dimensions of siphon chambers to effectively deliver the effluent in

proper volumes to the sub-surface irrigation system are given in the

following tables, which indicate widths of siphon chambers to agree in

general with the widths of the settling tanks to serve a given number of

persons, as shown in Chapter II. These tables of dimensions for siphon

chambers provide for two different capacities where the same number of

persons are served by the sewer, depending on the total lengths of

sub-surface tiling required, which in turn depend on the character of

the soil in which the sub-surface system is laid. The tables provide for

a division of the sub-surface tiling system into two parts up to a

system for 100 persons, and into three parts for a greater number of

persons. These tables also show the total length of lateral distributing

tiling in the sub-surface irrigation system necessary to distribute over

a sufficient area at the irrigation field, in both sandy soils and in

the heavier loams, the various quantities of sewage to be treated in the

different-sized tanks and discharged from the siphon chambers. The

tables also indicate the diameter of the siphon and the discharging

depth of each siphon.

As discussed in Chapter III, the siphon, in discharging, may draw upon

the upper 4 to 8 inches of sewage in the settling tank without

interfering with the efficiency of the tank. The dimensions of siphon

chambers for 75 or more persons in Table II, and for 35 or more persons

in Table III (see page 59), provide for such a draught upon the

settling-tank contents of from 4 to 8 inches when the siphon discharges.

This will decrease the cost of the plant somewhat and provide for a more

efficient form of siphon chamber. The last column in each table provides

for the proper height of dividing-wall between the settling tank and

siphon chamber to allow the drawing down of the settling-tank contents

as noted above.

[Illustration: FIG. 26.—Plan and Section of Sub-surface Irrigation

System.]

[Illustration: FIG. 27.—Plan and Section of a Portion of a Sub-surface

Irrigation System.]

The sub-surface irrigation or distributing system consists of a main

carrier or effluent sewer leading away from the siphon chamber to the

irrigation field, of two or more branches of this main carrier, and of

parallel lines of lateral distributing tiling extending at intervals of

4 to 6 feet from the branch carriers, or, in some locations, from each

side of the branch carriers.

The frontispiece shows the relation between the several portions of a

sub-surface irrigation system. The house sewer is shown leading to the

settling tank, and from the siphon chamber adjoining the settling tank

the main carrier or effluent sewer is shown leading to a diverting

manhole from which the effluent is carried at each discharge of the

siphon to the lateral lines of sub-surface tiling by the two branch

carriers.

Fig. 26 shows in plan and section a sub-surface irrigation system. The

section, which is drawn to a larger scale than the plan, shows the

settling tank and the adjoining siphon chamber. From this siphon chamber

the effluent sewer carries the discharge from the siphon to the

diverting manhole, at which point the effluent is diverted to the

different portions of the sub-surface tiling.

In Fig. 27 is shown in plan the diverting manhole and a small portion of

the sub-surface tiling system together with a section through the

diverting manhole and one of the lines of distributing tiling.

The main carrier should be of vitrified tile sewer pipe with cemented

joints, and should always have two or more branches at the irrigation

field in order to allow the use of different portions of the field in

turn for three days or a week at a time, thus allowing one of the

portions of the field to be resting for corresponding periods. The

branch carriers should be of vitrified tile also, and should have

cemented joints. If the diameter of the siphon is 5 inches, the main

carrier should be of 8–inch vitrified tile with a fall of at least 6

inches per 100 feet in order to quickly carry the dose from the siphon

chamber to the several lines of sub-surface tiling forming the

distributing system. With 3–inch siphons, a 6–inch main carrier may be

used, but the gradient or fall of the main carrier should then be at

least 12 inches per 100 feet, owing to the smaller capacity of the

6–inch pipe. In placing the siphon in position, when the siphon chamber

is being built, care should be taken to see that the trap or U-shaped

pipe is set plumb or in a vertical position. Concrete should then be

placed around the siphon to hold it in proper position and at the proper

height, and the trap should be filled with water before the bell is

placed in position. The bell should then be placed in position over the

long leg of the trap to prevent the materials used in construction from

being dropped into the siphon. The siphon should be set so that the

lower edge of the bell, or of that portion of the bell under which the

effluent is to flow, is three inches above the floor of the siphon

chamber.

[Illustration: FIG. 28.—Y-Branch of Vitrified Tile Pipe.]

In laying the distributing system, every second or third length of the

branch carriers, according to the porosity of the soil and the spacing

of the lines of distributing tiling, should consist of a Y-branch (see

Fig. 28), to which a one-eighth bend (see Fig. 29) should be fitted if

the lines of lateral tiling are to be laid at right angles to the main

carriers, as shown in Fig. 27; or the lateral tiling may be fitted

directly to the Y-branch if the lateral lines are to be led away from

the carrier at an angle of 45°, as shown in Fig. 30. The Y should branch

from the lower portion of the pipe, as shown in Fig. 28.

[Illustration: FIG. 29—Eighth Bend of Vitrified Tile Pipe.]

[Illustration: FIG. 30.—Sub-surface Tiling.]

The lateral tiling should be of three-inch agricultural tile (see Fig.

31), laid with a space of one-quarter inch between each length and with

a piece of tar paper or a half-collar of larger diameter pipe, as shown

in Fig. 32, placed over the joints to prevent clogging of the pipe with

earth. In the heavier soils the lateral lines of sub-surface tiling are

sometimes set in trenches eight to fourteen inches deep and about twelve

inches wide, filled with broken stone or gravel placed around the tiling

to within two or three inches of the ground surface, as shown in Fig.

32. This allows the effluent to seep away more readily, but while of

advantage in those soils the provision is not necessary in the more

porous soils.

[Illustration: FIG. 31.—Photograph of Tile laid as if for Sewage

Disposal.]

It is generally found that a sufficient length of sub-surface tiling

should be laid to provide for not more than one to three gallons of

effluent per day for each linear foot of tiling. In sandy soils there

should be at least thirty to forty feet of tiling for each person served

by the sewer, with six feet of space between the lines of tiling. This

length per person should be increased up to seventy or eighty feet for

the more compact sandy or gravelly loams, or the lighter clay loams,

with the lateral tiling spaced four feet apart. It is not considered

feasible to attempt to dispose of sewage by sub-surface irrigation in

soils which will not care for effluent when the greater lengths of

tiling per person, as stated above, will not prevent the appearance of

effluent on the surface. If, however, after the installation of a

sub-surface system in a rather heavy soil, it is found that proper

seepage of the effluent does not occur, the lateral branches may

sometimes be lengthened and the system then found to operate

satisfactorily.

[Illustration: FIG. 32.—Sub-surface Tiling with Broken Stone or Gravel

Surrounding Pipe.]

The lines of lateral tiling should be laid with the invert, or bottom of

the pipe, inside, from six inches to one foot below the surface, as

shown in Fig. 27. They should be parallel with the contours or at right

angles with the slope of the field, and should have a gradient or fall

of one-sixteenth of an inch to the foot when laid in sandy soil or sandy

loam, and of not more than one thirty-second of an inch to the foot when

laid in the heavier loams. To obtain such gradients for the sub-surface

tiling it is sometimes necessary to lay out the trenches along irregular

or curved lines, as shown in Fig. 33. The tiling should be laid near the

surface, as stated, and never deeper than twelve inches. The temperature

of the sewage will prevent its freezing even in very severe winter

weather, especially when the ground is covered with snow.

[Illustration: FIG. 33.—Sub-surface System on Irregular Ground.]

To provide for diverting the flow from the siphon chamber first into one

of the two portions into which the sub-surface system is divided, and

then, after an interval of three days or a week, into the other portion

of the system, at the point where the main carrier is to branch, a

ten-inch iron pipe casting (see Fig. 34), with its lower portion forming

the body of a double Y-branch of six-inch or eight-inch pipe, may be

placed, having a swinging blade or gate attached inside in a vertical

position. When, for example, the effluent has been passed for a week

into section B of the sub-surface system, the gate _C_, shown in Fig.

34, may be swung to the dotted position and the effluent, at each

discharge of the siphon chamber, will then pass through the branch

carrier _A_ to section A of the sub-surface system; or a double Y-branch

of iron pipe (see Fig. 35) or a cross may be placed at this point on the

main carrier when there are to be three sections of the sub-surface

system, and valves may be placed on the three branches of the main

carrier thus formed to permit of alternately shutting off the flow to

the various sections of the sub-surface tiling system (see also Fig.

30). Perhaps the simplest and most serviceable device, however, for

alternately resting different portions of the irrigation field is a

diverting manhole with stop planks or wooden sluices sliding in grooves

in the concrete walls or in a wooden frame, as shown in Fig. 27. (See

also Fig. 43, Chapter V.)

Where the ground-water level is not very deep below the surface, or a

clay or hardpan stratum occurs at a depth of a few feet, it is advisable

to underdrain the irrigation field by lines of open-jointed tiling laid

at right angles to the lateral distributing tiling and spaced about

fifteen feet apart. (See Fig. 36.)

[Illustration: FIG. 34.—Special Casting of Double Y-Branch with Swinging

Gate.]

[Illustration: FIG. 35.—Double Y-Branch with Valves on Branches of Main

Carrier.]

These underdrains should be placed at least four feet below the surface,

and inspection pipes should be placed over the outlets of the

underdrains or at the points where they discharge into a main

underdrain, in order to afford opportunity to determine if all portions

of the irrigation field are properly caring for the effluent. To provide

for the placing of the inspection pipes, a length of vitrified tile with

a Tee may be placed on each line of underdrain tiling near its junction

with the main underdrain. On this Tee, two or three lengths of vitrified

tile may be set, reaching to the ground surface and provided with a

removable wooden cover or a vitrified tile cap. This provision for

inspection is necessary where underdrains must be laid and where the

pollution of a stream is to be prevented, since it is often found that

through the activities of burrowing animals direct outlets from the

distributing tiling to the underdrains are formed and the final effluent

is therefore not sufficiently purified by seepage through the soil. It

is desirable for this reason to omit the underdrains when possible, and

in some instances a blind ditch may be constructed around two or three

sides of the field in order to intercept the ground-water flow and to

lower the ground-water level at the field, thus better insuring proper

seepage of the effluent distributed by the sub-surface tiling.

[Illustration: FIG. 36.—Sub-surface Tiling System with Underdrains.]

The essential features of the sub-surface irrigation system of sewage

disposal have been outlined above, and it may be said that this method

is especially adapted to the residence or single house. The method may

be employed with success to dispose of sewage from country clubs and

summer hotels, provided the soil conditions are favorable and proper

areas may be utilized. In these cases the comparatively short period

during each year in which the system is in use and the resulting long

periods of rest give opportunity for a recuperation of the soil and

permit the use of this system in comparatively large installations

where, under continuous operation, a different method of disposal would

be indicated. It should be borne in mind, however, that when any doubt

arises as to the suitability of the soil to care for sewage by this

method, and especially where considerable expense would be involved in

the installation of the system, competent engineering advice should be

sought by property owners before the installation is undertaken. In

fact, it is advisable in the case of all large plants of this type to

employ the services of a sanitary engineer to lay out the system, since

the matter of accurate gradients and proper operating arrangements then

becomes very essential to the success of the undertaking.

While it is not generally advisable to arrange for the disposal of

sewage by sub-surface irrigation when the number of persons served by

the sewer exceeds two hundred, this method will be found a most

satisfactory one if the general conditions at any point are favorable to

its use as heretofore described, and in such cases the adoption of this

system is strongly recommended to the owners of residences, summer

camps, summer hotels and boarding-houses, and to the managers of

moderate-sized institutions and of country clubs who must meet the

problem of properly disposing of sewage on their own premises.