CHAPTER IV

VENTILATION

Introduction

Ventilation as defined by Webster is, “To cause fresh air to

circulate; to cause inside resident impure air to be removed and

replaced with fresh, pure air, whether it be in building, streets,

mines, or sewers.”

Shakespeare speaks of sleep as “Nature’s second course.” Fresh air

may well be called “Nature’s tonic.” Everything else necessary for

good health may be provided, but if there is not a sufficient amount

of fresh air the tissues of the body can not perform their functions.

It is quite as necessary to have plenty of fresh, pure air as it is

to have a proper amount of wholesome food and pure water. Ordinarily

not enough attention is given the subject of ventilation, especially

of the average home.

The average adult breathes at the rate of seventeen or eighteen

respirations per minute. At each respiration about thirty cubic

inches of air passes in and out of the lungs. The air in the lungs

loses 4% of oxygen and absorbs about 3.5% to 4% carbon dioxide. The

nitrogen remains the same. The temperature of expired air is raised

to about 98.4% F. and contains approximately 5% aqueous vapor.

This volume of air inspired and expired during gentle respiration,

which is, as has been said, about thirty cubic inches, is known as

tidal air. By forced inspiration another 100 cubic inches of air

in addition to the tidal air may be taken into the lungs. This is

known as complemental air. By forced expiration it is possible to

expel from the lungs 100 cubic inches of air over and above the 30

cubic inches of tidal air; this is known as the supplemental air.

There is another 100 cubic inches which can not be expelled by the

most violent expiration; this is the residual air. The supplemental

air can, by forced expiration, be expelled from the lungs, but the

residual air can not. Altogether there is in the lungs during forced

inspiration about 330 cubic inches of air. An average adult gives off

about 0.71 cubic feet of carbon dioxide per hour.

Taking into consideration the amount of air breathed into the lungs

per hour and the amount of impurities carried into the breathing

zone by the expired air, it can readily be seen that the problem of

supplying a sufficient volume of pure air in the house is no small

problem.

The amount of fresh air needed for the average adult is estimated to

be 3,000 cubic feet per hour. The ventilating system that does not

provide this amount of air per hour without objectionable draughts

does not meet the requirements of modern hygiene.

In a system of ventilation it is not only a question of providing a

certain volume of air from the outside, but the great problem is to

provide a sufficient volume of pure air of proper temperature and of

proper humidity. Air that is laden with smoke, dust and suspended

matter, or that which contains gas or foul odors, is objectionable

and does not meet the requirements. Therefore, the source of the air

becomes important. The ventilating system must also keep the air in

proper circulation at a proper velocity.

The ventilating system of an ordinary building might seem a very

simple proposition, but when considered carefully it is a very great

problem and one that requires the careful attention of engineers

trained in that particular line.

It is not the object of ventilation to provide an indoor condition

identical with that outdoors, but it is to maintain a condition

indoors conducive to a normal expression of indoor life. It is

quite obvious that if indoor conditions were maintained identical

with outdoor conditions the desired results could not possibly be

obtained, for indoor life demands a much different environment. It is

necessary to give any system of ventilation as much attention as is

given a heating system in order to obtain the best results. No system

will work itself.

Sources of Impurities in Air

There are many processes carried on within the house that add to the

impurities of the air. Such sources may be classified as follows:

respiration of persons, impurities from heating and illumination, and

accidental sources from processes carried on within the house, such

as house cleaning and laundering.

It will be observed from a study of the amount of air inspired and

expired and the impurities carried from the body in the process that

one of the most common sources of vitiation of the air in houses is

respiration. That these expired poisons may be diluted or carried

out of the breathing zone it becomes necessary to have an adequate

ventilating system. If the room is heated by a stove impurities will

be added from coal dust and the dust of ashes. When the iron is

overheated it gives off carbon dioxide and other gases. Open fire or

an open blaze for lighting purposes consumes oxygen, gives off carbon

dioxide, raises the temperature and increases the amount of aqueous

vapor.

Vitiation from accidental sources consists of dust particles of

organic and inorganic detritus which are added to the air from walls,

floors, furniture and hangings. Other processes such as laundering

will add a certain amount of poisons and suspended matter to the air.

All this reveals the necessity for exchanging the inside air for pure

outside air.

Requirements of a Ventilating System

A ventilating system must not only bring about an exchange of air,

but it must also keep the inside air in proper circulation during

the time it is contained inside. Proper circulation of air is one of

the most important functions of ventilating systems.

The value of air circulation will be appreciated when it is known

that an aerial envelope is formed around the body when the air is

not kept moving and the temperature and humidity of this air will

resemble that of a very hot, humid summer day. The effects will also

be similar to those of heat exhaustion. This shows the importance of

keeping the air in circulation in order to carry away the poisons

that are being constantly excreted from the skin and through the

respiratory tract.

The effects of foul air are usually manifested as headache, fatigue,

lassitude, vertigo, nausea, vomiting, collapse and even death.

The chronic effects are anemia, debility, lowered vitality and

disturbances in digestion. Prolonged exposure to vitiated air will

necessitate increased adaptation on the part of Innate Intelligence.

If this exposure is carried to an excess it will draw upon the

adaptative forces of the body and make it more susceptible to the

invasion of toxins and subject to changes which it would not be when

under more natural environmental conditions.

It is now affirmed by the best hygienists that there is no great

objection to rebreathing air if provision is made for diffusion of

the carbon dioxide and if the bodily odors are eliminated. In this

way air may be properly warmed and kept recirculating; thus there

is a saving on fuel. If air is to be rebreathed it must first be

washed. There is, of course, a limit to the length of time air can

be recirculated. At no time is the recirculated air equal to outside

air and because this method is not properly regulated and carefully

controlled it is not considered safe for use.

Before considering methods for obtaining pure air it is interesting

to look at Nature’s purifying system. The effect of vegetation upon

the air is to consume carbon dioxide, especially in the sunlight.

The purifying effects of the sun’s rays on the organic particles,

the washing of the air by the rain which carries down the dissolved

gases and suspended impurities, the natural constant diffusion of the

air due to the wind, are all natural processes tending to keep the

outside air in a state of purity.

Man so far has been unable to find any artificial means of purifying

the air and therefore must provide means of admitting air from the

outside in a state conducive to sustaining indoor life.

Natural Means of Ventilation

Outside air may be polluted with dust, smoke and suspended matter and

it is then necessary to free the air of these impurities before it

enters the house. Especially is this true in cities and where large

buildings are to be ventilated. The most satisfactory methods of

ventilating a large building is the plenum and the vacuum systems.

[Illustration: _Window Ventilation._]

In the ordinary home, ventilation is through the natural openings

such as windows and doors, although special openings may be provided

which will admit fresh air and carry out the vitiated air. A great

deal of air is admitted through the crevice and openings around

windows and doors. A very simple method of airing a room in cold

weather when a direct draught is objectionable is to place a board

a few inches wide and as long as the width of the window beneath

the lower sash. This prevents the air from coming through the open

window, but permits it to enter between the upper and lower sashes.

This also has the advantage of directing the air current toward the

ceiling. This is very effective in the sick room and is so simple

that any one can use it.

[Illustration: _Window Mopper_]

The size and shape of the room to be ventilated must be taken into

consideration as well as the number of persons therein. The minimum

amount of space allowed for each person has been placed by various

authors at from 300 to 1,000 cubic feet, depending upon the nature of

the work carried on, the size and shape of the room and the type of

ventilation depended upon. In hospitals where fever cases are cared

for 2,500 cubic feet are desired, while in government barracks each

soldier is allowed 600 cubic feet.

[Illustration: _Window Ventilation_]

The necessity for a sufficient supply of pure air can not be

over-emphasized. When the windows and doors are used to ventilate the

house they should be thrown open at different times so that the house

air may be completely changed. We must not, however, go to the other

extreme and jeopardize the health of the occupants by keeping the

temperature too low, yet it has been proven that cool, fresh air is

more easily heated than warm vitiated air.

When air is admitted by special ducts they should be so arranged that

air may be evenly distributed over the room. The relative position of

the inlets to the outlets is a question upon which the engineers are

not exactly agreed. It is obvious, however, that their arrangement

must admit of a complete change of air at proper intervals and that

draughts will not be established directly between inlets and outlets.

It is generally conceded that the best results are obtained when

the inlet is placed above near the ceiling, and the outlet placed

directly below near the floor. In this way there seems to be a more

equitable distribution of the entering air and less likelihood of a

direct draught between the inlet and outlet. The outlet should never

be directly opposite the inlet, since the air will pass directly

through the room and there will be very little mixing with the room

air. If the room is crowded it is more desirable to admit the fresh

air from beneath, but when this is done there must be a great number

of inlets. In this way the fresh air is admitted more directly into

the breathing zone and at the same time advantage is taken of the

natural air currents in the room.

There are many patent devices on the market for ventilating through

the windows. Such devices are very good and may be used to an

advantage. Usually they are so built that the air is directed toward

the ceiling as it is admitted. The same desired end is accomplished

by placing a board under the lower sash as described above.

Mechanical Ventilation

By far the most satisfactory method of ventilating large buildings

is the mechanical method. This is not practical for small buildings

or homes because of the special devices that are required and the

expense of operation. Mechanical ventilation may be accomplished by

the plenum system, the vacuum system, or by the combined plenum and

vacuum systems. The most desirable results are obtained when both

systems are used and used in connection with the heating system.

Heating and ventilating are so closely related that they must be

considered one with the other. A poorly ventilated room is more

difficult to heat and an improperly heated room is difficult to

ventilate.

The =plenum system= consists of a fan to force the air into the

rooms. These fans are run by water motors or electricity whereby

the air is forced through ducts into the rooms. This system is made

necessary by the great buildings, basements and large steamships,

which could not be inhabited if natural ventilation was the only

method employed.

The =vacuum system= consists of suction fans whereby the vitiated

air is drawn out of the rooms and replaced by fresh air through

the natural openings. In this way natural ventilation may be made

more efficient, but this method in itself is not adequate for large

buildings.

The two systems, vacuum and plenum, are commonly used together

and when employed in connection with the heating device the very

best results are obtained. The amount of air, the temperature and

humidity, and the purity of the air may be regulated to a nicety in

this way.

A complete system of =vacuum and plenum= consists of plenum fans

for forcing the air into the rooms, vacuum or suction fans for the

removal of vitiated air, the ducts for conducting the air to and from

the rooms, the necessary machinery to run the fans, and a proper

heating system whereby the air may be warmed in the winter and cooled

by ice coils in the summer. It is also necessary to have a device for

washing the air.

Washing the Air

As the air is drawn into the buildings by the plenum fan it is passed

through a chamber where it is washed. This is done by forcing the

air through a spray of water. A water curtain is formed by forcing

water through perforated pipes placed across the chamber from each

other and the water thus sprayed made to intercept. As the air passes

through this curtain of water many of the impurities such as dust,

cinders, bacteria, some of the gases, particles of decomposition, and

epithelial cells, are removed. Washing does not remove carbon dioxide

or bodily odors. Washing is one of Nature’s methods of cleaning the

air as is seen in rain.

[Illustration: _Central heating with washed air._]

After the air is washed it is passed over tempering coils. In the

winter the air is warmed and in the summer it is cooled in this

way. The humidity is also controlled. It can thus be seen that

this method, although rather expensive, is the only real method of

ventilating large buildings satisfactorily.