IMPROVED APPARATUS FOR PREPARING FLUORINE.

In his paper of 1887, the main outlines of which were given in

_Nature_ at the time (1887, vol. xxxvii., p. 179), M. Moissan showed

that pure hydrofluoric acid readily dissolves the double fluoride of

potassium and hydrogen, and that the liquid thus obtained is a good

conductor of electricity, rendering electrolysis possible. It will be

remembered that, by passing a strong current of electricity through

this liquid contained in a platinum apparatus, free gaseous fluorine

was obtained at the positive pole and hydrogen at the negative pole.

The amount of hydrofluoric acid employed in these earlier experiments

was about fifteen grms., about six grms. of hydrogen potassium

fluoride, HF.KF, being added in order to render it a conductor. Since

the publication of that memoir a much larger apparatus has been

constructed, in order to obtain the gas in greater quantity for the

study of its reactions, and important additions have been made, by

means of which the fluorine is delivered in a pure state, free from

admixed vapor of the very volatile hydrofluoric acid. As much as a

hundred cubic centimeters of hydrofluoric acid, together with twenty

grms. of the dissolved double fluoride, are submitted to electrolysis

in this new apparatus, and upward of four liters of pure fluorine is

delivered by it per hour.

This improved form of the apparatus is shown in the accompanying

figure (Fig. 1), which is reproduced from the memoir of M. Moissan. It

consists essentially of two parts--the electrolysis apparatus and the

purifying vessels. The electrolysis apparatus, a sectional view of

which is given in Fig. 2, is similar in form to that described in the

paper of 1887, but much larger.

The U-tube of platinum has a capacity of 160 c.c. It is fitted with

two lateral delivery tubes of platinum, as in the earlier form, and

with stoppers of fluorspar, F, inserted in cylinders of platinum, _p_,

carrying screw threads, which engage with similar threads upon the

interior surfaces of the limbs of the U-tube. A key of brass, E,

serves to screw or unscrew the stoppers, and between the flange of

each stopper and the top of each branch of the U-tube a ring of lead

is compressed, by which means hermetic closing is effected. These

fluorspar stoppers, which are covered with a coating of gum lac during

the electrolysis, carry the electrode rods, _t_, which are thus

perfectly insulated. M. Moissan now employs electrodes of pure

platinum instead of irido-platinum, and the interior end of each is

thickened into a club shape in order the longer to withstand

corrosion. The apparatus is immersed during the electrolysis in a bath

of liquid methyl chloride, maintained in tranquil ebullition at -23°.

In order to preserve the methyl chloride as long as possible, the

cylinder containing it is placed in an outer glass cylinder containing

fragments of calcium chloride; by this means it is surrounded with a

layer of dry air, a bad conductor of heat.

The purifying vessels are three in number. The first consists of a

platinum spiral worm-tube of about 40 c.c. capacity, immersed also in

a bath of liquid methyl chloride, maintained at as low a temperature

as possible, about -50°. As hydrofluoric acid boils at 19.5°

(Moissan), almost the whole of the vapor of this substance which is

carried away in the stream of issuing fluorine is condensed and

retained at the bottom of the worm. To remove the last traces of

hydrofluoric acid, advantage is taken of the fact that fused sodium

fluoride combines with the free acid with great energy to form the

double fluoride HF.NaF. Sodium fluoride also possesses the advantage

of not attracting moisture. After traversing the worm condenser,

therefore, the fluorine is caused to pass through two platinum tubes

filled with fragments of fused sodium fluoride, from which it issues

in an almost perfect state of purity. The junctions between the

various parts of the apparatus are effected by means of screw joints,

between the nuts and flanges of which collars of lead are compressed.

During the electrolysis these leaden collars become, where exposed to

the gaseous fluorine, rapidly converted into lead fluoride, which

being greater in bulk causes the joints to become hermetically sealed.

In order to effect the electrolysis, twenty-six to twenty-eight Bunsen

elements are employed, arranged in series. An ampere meter and a

commutator are introduced between the battery and the electrolysis

apparatus; the former affording an excellent indication of the

progress of the electrolysis.

[Illustration: FIG. 1.--FLUORINE APPARATUS.]

As the U-tube contains far more hydrofluoric acid than can be used in

one day, each lateral delivery tube is fitted with a metallic screw

stopper, so that the experiments may be discontinued at any time, and

the apparatus closed. The whole electrolysis vessel is then placed

under a glass bell jar containing dry air, and kept in a refrigerator

until again required for use. In this way it may be preserved full of

acid for several weeks, ready at any time for the preparation of the

gas. Considerable care requires to be exercised not to admit the vapor

of methyl chloride into the U-tube, as otherwise violent detonations

are liable to occur. When the liquid methyl chloride is being

introduced into the cylinder, the whole apparatus becomes surrounded

with an atmosphere of its vapor, and as the platinum U-tube is at the

same instant suddenly cooled the vapor is liable to enter by the

abducting tubes. Consequently, as soon as the current is allowed to

pass and fluorine is liberated within the U-tube, an explosion occurs.

Fluorine instantly decomposes methyl chloride, with production of

flame and formation of fluorides of hydrogen and carbon, liberation of

chlorine, and occasionally deposition of carbon. In order to avoid

this unpleasant occurrence, when the methyl chloride is being

introduced the ends of the lateral delivery tubes are attached to long

lengths of caoutchoue tubing, supplied at their ends with calcium

chloride drying tubes, so as to convey dry air from outside the

atmosphere of methyl chloride vapor. If great care is taken to obtain

the minimum temperature, this difficulty may be even more simply

overcome by employing a mixture of well pounded ice and salt instead

of methyl chloride; but there is the counterbalancing disadvantage to

be considered, that such a cooling bath requires much more frequent

renewal.

[Illustration: FIG. 2.]

Scientific American Supplement, No. 832, December 12, 1891 · 第 50 / 75 题