10,000,000-Lb. Testing Machine.]

_Concrete and Cement Investigations._--The investigations relating to

concrete include the examination of the deposits of sand, gravel, stone,

etc., in the field, the collection of representative samples, and the

shipment of these samples to the laboratory for analysis and test. These

tests are conducted in connection with the investigation of cement

mortars, made from a typical Portland cement prepared by thoroughly

mixing a number of brands, each of which must meet the following

requirements:

Specific gravity, not less than 3.10;

Fineness, residue not to exceed 8% on No. 100, nor 25% on No. 200

sieve;

Time of setting: Initial set, not less than 30 min.; hard set, not

less than 1 hour, nor more than 10 hours.

Tensile strength: Requirements applying to neat cement and to 1 part

cement with 3 parts standard sand:

-------------------------------+--------------+----------

| Neat cement. | 1:3 Mix.

Time specification. | Pounds. | Pounds.

-------------------------------+--------------+----------

24 hours in moist air | 175 | ...

7 days (1 day in moist air, | 500 | 175

6 days in water) | |

28 days (1 day in moist air, | 600 | 250

27 days in water) | |

-------------------------------+--------------+----------

Constancy of volume: Pats of neat cement, 3 in. in diameter, ½ in.

thick at center, tapering to a thin edge, shall be kept in moist air

for a period of 24 hours. A pat is kept in air at normal temperature

and observed at intervals for at least 28 days. Another pat is kept in

water maintained as near 70° Fahr. as practicable, and is observed at

intervals for at least 28 days. A third pat is exposed in an

atmosphere of steam above boiling water, in a loosely-closed vessel,

for 5 hours. These pats must remain firm and hard and show no signs of

distortion, checking, cracking, or disfiguration.

The cement shall not contain more than 1.75% of anhydrous sulphuric

acid, nor more than 4% of magnesium oxide.

A test of the neat cement must be made with each mortar series for

comparison of the quality of the typical Portland cement.

The constituent materials are subjected to the following examination and

determinations, and, in addition, are analyzed to determine the

composition and character of the stone, sand, etc.:

1.--Mineralogical examination,

2.--Specific gravity,

3.--Weight, per cubic foot,

4.--Sifting (granulometric composition),

5.--Percentage of silt and character of same,

6.--Percentage of voids,

7.--Character of stone as to percentage of absorption, porosity,

permeability, compressive strength, and behavior under treatment.

Physical tests are made to determine the tensile, compressive, and

transverse strengths of the cement and mortar test pieces, with various

preparations of cement and various percentages of material. Tests are

also made to determine porosity, permeability, volumetric changes in

setting, absorption, coefficient of expansion, effect of oil, etc.

Investigation of concretes made from mixtures of typical Portland

cement, sand, stone, and gravel, includes tests on cylinders, prisms,

cubes, and other standard test pieces, with various proportions of

materials and at ages ranging from 30 to 360 days. Full-sized plain

concrete beams, moulded building blocks, reinforced concrete beams,

columns, floor slabs, arches, etc., are tested to determine the effect,

character, and amount of reinforcement, the effect of changes in volume,

size, and composition, and the effect of different methods of loading

and of supporting these pieces, etc.

These investigations include detailed inquiry in the field and research

in the chemical and physical laboratories regarding the effects of

alkaline soils and waters on structures of concrete being built by the

Reclamation Service in the arid regions. It has been noted that on

certain of the Reclamation projects, notably on the Sun River Project,

near Great Falls, Mont., the Shoshone Project, near Cody, Wyo., and the

Carlsbad and Hondo Projects in the Pecos Valley, N. Mex., structures of

concrete, reinforced concrete, building stones, brick, and tile, show

evidence of disintegration. This is attributed to the effects of

alkaline waters or soils coming into contact with the structures, or to

the constituent materials used. In co-operation with the Reclamation

Service, samples of the waters, soils, and constituent materials, are

collected in the field, and are subjected to careful chemical

examination in the mineral laboratories at Pittsburg.

[Illustration: PLATE XV.

Fig. 1.--Characteristic Failures of Reinforced Concrete Beams.

Fig. 2.--Arrangement of Static Load Test for Reinforced

Concrete Beams.]

The cylinders used in the percolation tests are composed of typical

Portland cement mixed with sand, gravel, and broken stone of known

composition and behavior, and of cement mixed with sand, gravel, and

broken stone collected in the neighborhood of the Reclamation projects

under investigation.

[Illustration: Fig. 5.

Transactions of the American Society of Civil Engineers, vol. LXX, Dec. 1910 Federal Investigations of Mine Accidents, Structural Materials and Fuels. Paper No. 1171 · 第 22 / 46 题