TABLE.

======+======+=======+=========+================+======+=====+=======+======

| | | |Horse-power of | | | |

| | | Gallons |Boiler, based on| | | |

Steam |Water |Stroke,| per |30 lbs. of water|Steam | Ex- |Suction| Dis-

Cylin-|Cylin-|Inches.| Single | per H. P. | Pipe |haust| Pipe |charge

der | der | |Stroke of| per hour, | |Pipe | | Pipe

| | | Each | which the pump | | | |

| | | Piston. | will supply | | | |

| | | | with ease. | | | |

------+------+-------+---------+----------------+------+-----+-------+------

4 | 2-1/2| 4 | .084 | 165 H. P. | 1/2 | 3/4 | 2 | 1-1/2

4-1/2| 2-3/4| 6 | .154 | 300 „ | 1/2 | 3/4 | 2-1/2 | 2

5-1/2| 3-1/2| 6 | .15 | 500 „ | 1 |1-1/4| 3 | 2-1/2

| | | | | | | |

6 | 4 | 8 | .435 | 870 „ | 1 |1-1/4| 3-1/2 | 3

7 | 4 | 8 | .435 | 870 „ | 1-1/4|1-1/2| 3-1/2 | 3

7 | 4-1/2| 8 | .55 | 1,100 „ | 1-1/4|1-1/2| 4 | 3

| | | | | | | |

8 | 5 | 10 | .85 | 1,700 „ | 1-1/2| 2 | 4-1/2 | 3-1/2

8 | 5 | 12 | 1.02 | 2,000 „ | 1-1/2| 2 | 4-1/2 | 3-1/2

9 | 5-1/2| 10 | 1.03 | 2,000 „ | 1-1/2| 2 | 4-1/2 | 4

| | | | | | | |

10 | 6 | 10 | 1.225 | 2,450 „ | 2 |2-1/2| 5 | 4-1/2

10 | 6 | 12 | 1.469 | 2,900 „ | 2 |2-1/2| 5 | 4-1/2

12 | 7 | 12 | 2.00 | 4,000 „ | 2 |2-1/2| 6 | 5

------+------+-------+---------+----------------+------+-----+-------+------

The capacity for boiler feeding in the table is based upon sixty single

strokes for each pump per minute.

The suction and discharge openings, as will be seen in the figure, are

on both sides. The water piston is packed for hot and cold water and

special valves are furnished as may be necessary.

Pumps and Hydraulics, Part 2 (of 2) · 第 93 / 185 题