BRIEF SANITARY MATTERS IN CONNECTION WITH ISOLATED COUNTRY HOUSES.[4]

[Footnote 4: Read before the Boston Society of Civil Engineers, April 1884

_Journal A. of E. Societies_.]

By E.W. BOWDITCH, C.E.

I am unable to tell you what is generally considered the best practice,

for I am not sure there are any definitely established rules; therefore I

can only explain _my_ ways of doing such work, which, though I try to make

as complete and at the same time as simple as possible, I know to be far

from perfect.

Plumbing and drainage work has grown up unconsciously with my landscape

gardening, and not finding any texts or practice that seemed wholly

satisfactory, I have been forced to devise new arrangements from time to

time, according to the requirements of the case in hand.

To give all the details of house plumbing this evening, or any _one_

evening, would be impossible, for lack of time, and not worth while even

if there was time, as much of it would prove matter of little or no

interest. I will confine my remarks, therefore, to certain elements of the

work where my practice differs, I believe, essentially from that of most

engineers, and where perhaps my experience, if of no assistance to other

members of the Society, may excite their friendly criticism in such a way

as to help me.

There are two kinds of country places that I am liable to be called upon

to prescribe for:

_First._ A new place where nothing has been arranged.

_Second._ An old place where the occupants have been troubled either by

their outside arrangements or by fixtures or pipes within.

Under the first head let us suppose a small tract of perhaps two acres of

land in some inland town, where the family intends to live but six months

in the year, though they are liable to reside there the whole twelve.

There are no sewers and no public water. The soil is a stiff, retentive

clay, rather wet in spring. The desire is expressed to have plumbing and

drainage that shall be as inexpensive as possible, but that shall be

entirely safe.

In considering the arrangements inside the house, I find myself in the

same predicament as the French surgeon, a specialist upon setting the

bones of the arm, who, when a patient was brought him with his right arm

broke, expressed his sorrow at being unable to be of assistance, as his

specialty was the left arm.

I have endeavored to post myself thoroughly upon house plumbing, but

confess to only knowing partially about the wastes; the supplies I do not

feel competent to pass upon.

One class of annoyance caused by plumbing, perhaps the principal one, is

due to the soil pipe or some of its fittings.

Second quality of iron, poor hanging, insufficient calking, careless

mechanics, putty, cement, rag, or paper joints--all these and a dozen

other things are liable to be sources of trouble. Subordinate wastes are

apt to be annoying, occasionally, too, to a less extent.

The mechanical work can always be superintended, and within certain limits

may be made secure and tight; not so easy, however, with the materials.

There is seldom a valid excuse for ever making waste pipes, within a

building, of anything but metal.

Earthen tile is frequently used; also, to a limited extent, brick, stone,

and wood; twice I have found canvas--all these, however, are inferior, and

should never be accepted or specified. The writer believes that at the

present time, hereabouts, lead and iron are more used for wastes than any

other materials, and are found the most satisfactory on the whole.

One or two arrangements, relative to the wastes, I have made use of that

are not, so far as known, in general use, and that may not be the best,

though they have served me many good turns, and I have not succeeded in

devising any better.

Soil pipe, as it is usually put in, is apt to be of cast iron, four inches

in diameter, and is known in the market as "heavy" or "extra heavy." For

some years the tar-coated or black enameled pipe has been the favorite, as

being the more reliable, the writer in common with others making use of

the same freely, until one day a cracked elbow, tar coated, was detected.

Since that time plain, untarred pipe has been specified, and subjected to

the so-called kerosene test, which consists of swabbing out each pipe with

kerosene or oil and then allowing it to stand for a few hours. A moment's

thought will convince any one that when a pipe is asphalted or tar coated

it is very difficult to detect either sand holes or small cracks, and the

difficulty of proper calking is increased, as lead does not cling so well

to the tar as to plain iron.

At present, the kerosene test, so far as the writer is concerned, is a

misnomer, because raw linseed oil is used exclusively as giving more

satisfactory results, and being less troublesome to apply.

I have here a length of the ordinary "heavy 4" commercial soil pipe,

plain, and selected at random. Yesterday noon I had it oiled at my office,

in order to be ready for to-night, and you see, by the chalk marks I have

made, just where the leaks were and their area. I may say here that a

sound pipe of this caliber and standard weight is the exception rather

than the rule, and it was selected for this experiment merely to try and

show the reaction a little better than the heavier pipe might.

Experiments of this nature I have carried along for the past two years,

and I am glad to say that, since I began, the quality of the soil pipe

furnished by the dealers for my work seems appreciably better than at

first. Whether the poorer pipe is still made and sold to other customers I

have no means of knowing; probably it is, however.

A large quantity of the pipe is now being tested at my suggestion by the

Superintendent of Construction of the Johns Hopkins Hospital, at

Baltimore. I have not yet heard the results from him, but doubtless they

will be interesting. A brief summary of the results may be of some

interest.

The different makers of soil pipe generally used by plumbers hereabouts

are:

Mott & Company, Abendroth, Blakslee, Dighton, Phillips & Weeden, and

Bartlett, Hayward & Co.

On 4" extra heavy pipe my results have been as follows:

Percentage passed as good, single hub. 60 per ct. to 70 per ct.

Percentage passed as good, double. 20 per ct. to 80 per ct.

Percentage passed special castings,

including Y's and T's. 60 per ct.

5" pipe extra heavy:

Percentage passed as good, single hub. 25 per ct. to 35 per ct.

Percentage passed as good, double. No record.

Percentage special castings,

including Y's and T's. 60 per ct.

It has been stated to me by dealers that the tar coating does away with

the necessity of any such test as the oil; while I am not prepared to

acknowledge or deny the statement, it is well known that much poor pipe is

tar-coated and sold in the market as good, and when coated it is almost

impossible to detect any but _very_ defective work.

The price customers are obliged to pay for soil pipe, either "heavy" or

"extra heavy," is very high indeed, even taking off the discounts, and

amounts (as I figure it) to $70 per long ton for 4" pipe. The present rate

for the best water pipe of the same caliber is about $38 (now $29) per

long ton, and the additional charge for soil pipe should guarantee the

very best iron in the market, though it appears to be rarely furnished.

It is asserted that all soil pipe is tested to a 50-pound water pressure.

I beg leave to question the absolute truth of this, unless it be

acknowledged that pipe is sold indiscriminately, whether it bears the test

or not, for more than once I have found a single length of soil pipe (5

feet) that could not bear the pressure of a column of water of its own

height without leaking.

Having obtained a satisfactory lot of soil pipe and fittings, the next

trouble comes with the lead calking. Unfortunately, it is frequently found

that very shallow joints are made instead of deep ones, and hard lead used

instead of soft. My rule is, soft lead, two runnings and two calkings. By

soft lead I mean pig lead, and by hard lead I mean old pipe and scrap lead

that may have been melted a dozen times. Incidentally it may be remarked

that it is quite difficult to calk a tight joint on the heavy pipe; the

process will crack the hub.

The fixtures used in a house are of minor importance--there are dozens of

good patterns of every class. If they are carefully put in, and provided

with suitable traps placed just as close to the fixture as possible, the

result will usually be satisfactory.

Very few instances occur where traps are placed as close to the fixtures

they serve as they might be, and yet a very short length of untrapped

pipe, when fouled, will sometimes smell dreadfully. A set bowl with trap

two feet away may become in time a great nuisance if not properly used. A

case in point where the fixture was used both as a bowl and a urinal was

in a few months exceedingly offensive--a fact largely (though not wholly)

due to its double service.

I have never met two sanitarians who agreed upon the same water-closets,

bowls, faucets, traps, etc.

Of course, the soil pipe will be carried, of full size, through the roof,

and sufficiently high to clear all windows.

Avoid multiplicity of fixtures or pipes; cut off all fixtures not used at

least twice a week, lest their traps dry out; have all plumbing as simple

as possible, and try and get it all located so that outside air can be got

directly into all closets and bath-rooms. As far as possible, set your

fixtures in glass rather than tiles or wood. Carry the lower end of the

main drain at least five feet beyond the cellar walls of the building, of

cast iron.

Let us now look at the outside work. The main drain (carrying everything

except the kitchen and pantry sinks) goes through a ventilated running

trap. An indirect fresh air inlet is provided on the house side of the

trap (example), to prevent annoyance from puffing or pumping, or, better

still, a pipe corresponding to the soil pipe is carried up on the outside

of the house.

The running trap ventilator should be of the same diameter as the main

drain (4 inch), and serve as a main drain vent also. Carry this pipe on

the outside of the house as high as the top of the chimney.

A grease-trap should be provided for the kitchen and pantry sinks.

Formerly my custom was to put in brick receptacles; it is now to put in

Portland cement traps (Henderson pattern), though perhaps I may succeed in

devising a cast-iron one that will answer better. The brick ones were

occasionally heaved by the frost, and cracked; the Portland cement ones

answer better, and when thoroughly painted with red lead do not soak an

appreciable quantity of sewage to be offensive, but are too high priced

($28 each). I have made one or two patterns for cast-iron ones, but none

as yet that I feel satisfied with.

Beyond the running trap an Akron pipe should convey the sewage to a tank

or cesspool.

Our supposable case is the second most difficult to take care of. The

worst would be ledge. We have to contend with, however, hard, wet,

impervious clay.

The best way undoubtedly is to underdrain the land, and then to distribute

the sewage on the principle of intermittent downward filtration. This is

rather expensive, and a customer is rarely willing to pay the bills for

the same. I should always advise it as the best; but where not allowed to

do so, I have had fair success with shallow French drains connecting with

the tank or cesspool.

Siphon tanks, such as are advised by many sanitarians, that were used

first in this country, I believe, by Mr. Waring, I have not been very

successful with. Obstructions get into the siphon and stop it up, or it

gets choked with grease. I prefer a tight tank, provided with a tell-tale,

and that is to be opened either by a valve operated by hand, or that is

arranged with a standing overflow like a bath tub, and that can be raised

and secured by a hook.

* * * * *

Scientific American Supplement, No. 484, April 11, 1885 · 第 27 / 55 题