A PLUMBING TEST.

A recent trial of a smoke rocket for testing drains, described by Mr.

Cosmo Jones in the _Journal of the Society of Arts_, is deserving of

interest. The one fixed upon is 10 in. long, 2½ in. in diameter, and with

the composition "charged rather hard," so as to burn for ten minutes. This

gives the engineer time to light the fuse, insert the rocket in the drain,

insert a plug behind it, and walk through the house to see if the smoke

escapes into it at any point, finishing on the roof, where he finds the

smoke issuing in volumes from the ventilating pipes. The house

experimented upon had three ventilating pipes, and the smoke issued in

dense masses from each of them, but did not escape anywhere into the

house, showing that the pipes were sound. If the engineer wishes to

increase the severity of the test, he throws a wet cloth over the top of

the ventilating pipe, and so gets a slight pressure of smoke inside it.

* * * * *