DIMENSIONS

Table 3 gives recommended dimensions for fireplaces of various widths and

heights.

If a damper is installed, the width of the opening j, figure 34, will

depend on the width of the damper frame, the size of which is fixed by

the width and depth of the fireplace and the slope of the back wall. The

width of the throat proper is determined by the opening of the hinged

damper cover. The full damper opening should never be less than the flue

area. Responsible manufacturers of fireplace equipment give valuable

assistance in the selection of a suitable damper for a given fireplace. A

well-designed and well-installed damper should be regarded as essential

in cold climates.

When no damper is used, the throat opening j should be 4 inches for

fireplaces not exceeding 4 feet in height.