Spark Arresters

Spark arresters are desirable and, where chimneys are near combustible

roofs, lumber, forests, etc., they are sometimes required, depending on

the kind of fuel, waste materials, or refuse that may be burned and the

amount of deposits that may accumulate in the flues. While arresters

cannot be depended on to eliminate entirely the discharge of sparks under

all conditions; yet, when properly built and installed, they materially

reduce spark hazard.[4]

[4] See Standards for Construction and Installation of Spark Arresters

for Chimneys and Stacks, published by the National Fire Protection

Association.

In general all parts, whether of wire, expanded metal, or perforated

sheets, give longer service if they are of rust-resistant material.

Arresters for domestic purposes should have vertical sides extending

upward not less than 9 inches so as to provide a gross area of surface at

least twice the net flue area. They should be kept outside of the flue

area and be securely anchored to the chimney top.

Openings in the screen not larger than five-eights of an inch nor smaller

than five-sixteenths of an inch are advisable. Commercially made screens

can be purchased which generally last several years. Arresters must be

kept adjusted in position and renewed when the openings are worn larger

than the normal screen openings.