“This work fills up a hiatus in the literature of medical electricity.

It purposes to teach (to use the words of the preface) ‘the busy

practitioner not only when to use electricity, but in explicit and full

detail how;’ and in ‘moderate bulk to contain only what it is essential

to master.’ Dr. Tibbits’ object has been to give the results of the

best work, and to this end he has availed himself freely of the large

experience of the Electrical Room of the National Hospital for the

Paralysed and Epileptic.

“The work is what it professes to be, and is a handbook in the best

sense of the work. The book, indeed, answers thoroughly to the author’s

description: that he has ‘throughout endeavoured to keep constantly in

view the practitioner rather than the theorist,’ especially in points

of detail which are of importance in order to secure the successful

application of electricity, and to insure (a not insignificant matter

in this respect) the comfort of the patient.”--_The Lancet._

“There is not a word of exaggeration, or of fanciful hypothesis in the

book, and, above all, there is not the least suggestion that there

is after all a mystery behind, and that the reader would do well to

come to an expert for advice. On the contrary, everything is made so

clear that any practitioner, whether he previously knew anything of

electricity or not, may from this book at once begin the practical

use of it, and if there are any lingering doubts in the minds of some

ultra-conservative persons as to the practical value of electrical

treatment, this book should dispel them.... the busiest practitioner

can, without difficulty, learn how to effect a large amount of

good which he was previously quite unable even to attempt.”--_The

Practitioner._

“As Medical Superintendent of the National Hospital for the Paralysed

and Epileptic, as well as through private practice. Dr. Tibbits has

had ample opportunities of studying the application of electricity to

medicine, and in the volume under notice, which aims principally at

giving full and explicit details within convenient limits, _how to

use electricity_, we are bound to say this object is fairly carried

out.”--_The Dublin Journal of Medical Science._

“The exact value of electricity as a therapeutic agent is imperfectly

understood. That it is of great value in some cases as a means of

improving nutrition, relieving pain, and exercising disused muscles,

is undoubted, but still its exact value in all cases remains to be

settled, and in Dr. Tibbits’ book we find a guide which will, at all

events, help us to a solution of some of our difficulties.--_The

Medical Times and Gazette._

“Dr. Tibbits, who is known as an authority upon electricity, has

written a concise book upon this subject for the general practitioner,

embracing only the valuable part of the existing knowledge. The work is

written in a condensed style, and is well adapted for the practitioner

who does not make a specialty of electrical treatment.”--_The New York

Medical Journal._

LONDON: J. & A. CHURCHILL.

* * * * *

_DIRECTIONS FOR USING THE_ HAMMOND Wall Cabinet

MANUFACTURED BY _THE WAITE & BARTLETT MAN’F’G CO._, 143 East 23d

Street, New York.

TO USE THE GALVANIC CURRENT.

To use the galvanic current place the ends of the conducting cords

in the two binding posts marked =13-13=. Place the socket of current

selector (=20=) on the pin marked O, and turn the lever of selector

on pin No. =1=, or on any number, according to the number of cells

desired; at the same time see that all the switch levers are on their

blank buttons, except the one at left of current selector, which should

be on its left-hand button marked Constant.

If it is desired to use cells from any other part of the series, place

the socket on the pin from which it is desired to begin, and having

previously moved the lever ahead of this pin move it along until the

desired number of cells intervenes between socket and lever. The number

of cells in circuit when the socket is not on O, but on a pin with a

number, is the difference between the number of the pin and number on

which the lever rests, for instance, if socket is on pin =12= and lever

on pin =22=, then =10= cells are being used, the starting point being

=12= cells from any part of the series may thus be brought into the

circuit. If socket be placed on pin =39= and lever on pin =40= then the

=40=th cell would be in use only.

_Always keep the socket on the lowest number and the lever on the

highest, as putting socket ahead of lever would reverse the current._

Should, through any accident, a cell become disconnected or run down,

or should it get out of order from any cause, it is only necessary to

short-circuit the cells and throw the milli-ampere-meter in circuit

by adjusting the switch =10=. By placing the socket on the pin marked

O and selecting cell after cell with the lever, the defective cell is

easily found by the milli-ampere-meter failing to deflect when the pin

corresponding to the defect is reached.

TO OBTAIN THE INTERRUPTED GALVANIC CURRENT.

To obtain the interrupted galvanic current, move the switch at left

of selector on to button marked interrupted, then turn the switch

just above the vibrator on to its button marked =11=, by adjusting

the screws at =14= and =15= the proper degree of vibration will be

obtained. It is necessary that the point of the screws at =15= should

touch the plate with every vibration as the current passes through at

this point and unless it touches, connections would not be made.

TO MEASURE THE RESISTANCE OF THE PATIENT.

To measure the resistance of the patient turn the lever at the left

of selector on to the button =8= marked milli-ampere-meter and wire

rheostat. Supposing him to have the electrodes in his hands and a

current from =30= cells registers =8= milli-amperes; without changing

any other conditions, throw the upper left-hand lever =10= on button

marked rheostat and milli-ampere-meter only. The patient will now be

thrown out and the needle will fly around as far as it can go.

Begin by throwing in resistance, which is done by manipulating the top

row of levers, until the needle which will have retraced its course

rests directly over the division marked =8= milli-amperes or whatever

may have been the previously recorded amount. The numbers on uncovered

buttons added together will be the resistance of the patient. The known

resistance having taken the place of the patient.

_The upper left-hand lever should at all times except for purposes of

measuring the resistance of a patient, be kept on its blank button, or

the battery will be short circuited and injured._

THE POLE CHANGER.

The pole changing lever above the two posts marked =13-13=, when

pressed between the two right-hand springs makes the right-hand binding

post positive, and when pressed between the two left-hand springs the

left-hand post becomes positive and the right negative.

GRAPHITE RHEOSTAT.

When the left-hand lever is placed on button =9= it throws the graphite

rheostat (=16=) into circuit. To use the rheostat first draw up the

rod (=17=). By slowly pressing the rod down through the graphite it

gradually lessens the resistance thereby increasing the current without

shock to the patient. With this rheostat you can place any number of

cells in the circuit.

THE DE WATTEVILLE SWITCH.

The de Watteville switch is placed directly above the pole changer

is used for obtaining either the galvanic or the faradic current

separately or the two combined. When the double lever rests on figure

=1= and =3= the galvanic alone can be used; can when on =3= and =5= the

faradic can be alone used and when on =2= and =4= the two currents are

combined and used without changing the conducting cords.

THE FARADIC APPARATUS.

The Faradic apparatus of this cabinet combines a fast and slow

interrupter also a single contact key. The style of coil used is the

Du Bois-Raymond. To use =Primary= coil, place the two tips on ends of

conducting cords into the two binding posts in front of the coil, the

others being connected with any desired electrodes. The strength is

increased by drawing the coil to the =Right=, first placing switch at

right end of coil on button marked P.

To use the secondary coil remove the tips of cords from primary posts;

then place the ends of cords in the two binding posts =13-13= and place

switch on right end of coil on button marked =S=. To increase the

strength of secondary, push coil to the =Left= gradually, which is just

=Opposite= to what is done in case of primary current.

THE USE OF THE INTERRUPTER.

To use the rapid interrupter which works against the end of core it

is only necessary to adjust the screw F, and any degree of vibration

may be obtained. The same may be said of the slow interrupter which is

adjusted by the screw D, but it is further controlled by the sliding

weight at E. By sliding the weight up and down the interruptions are

varied from very slow to rapid.

The higher the weight the slower the interruptions and vice-versa. At

button G, is the “single contact” used in obtaining single impulse

contractions.

The different interrupters may be placed in circuit by a switch on

the base of the Cabinet which works over a series of buttons marked

S, F and C which put in operation the slow, fast or single contact

interrupters, as desired.

DIRECTIONS FOR CONNECTING CELLS.

Fill the cells according to the directions on the cell label, and

connect the wires of the cable to the cells, as shown in the cut; No.

O being attached to zinc of the first cell, No. =1= to the carbon of

the first cell, while at the same time the carbon of the first cell

connected to the zinc of the second cell by strip from the carbon of

cell, No. =2= wire of the cable to the carbon of the second cell, and

so on, the last wire being connected to the carbon of the last cell, as

shown by No. =40=. The two wires marked faradic should be connected as

shown, the four cells being placed in two rows of two each, the zincs

and carbons being connected together as shown in diagram.

* * * * *

Transcriber’s Notes:

Footnotes have been moved to the end of each chapter and relabeled

consecutively through the document.

Illustrations have been moved to paragraph breaks near where they are

mentioned.

References in the text to illustrations have been standardized.

Sidenotes originally appearing near the start of a paragraph are

positioned at the beginning of the paragraph; sidenotes in the middle

of long paragraphs are positioned near the relevant sentences.

Punctuation has been made consistent.

Variations in spelling and hyphenation were retained as they appear in

the original publication, except that obvious typographical errors have

been corrected.

How to Use a Galvanic Battery in Medicine and Surgery A Discourse Delivered Before the Hunterian Society, Third Edition · 第 6 / 6 段