Coefficients for Tile Quantities

_Dimensions of

Tile Face_ _Coefficient_

4" × 12' 2.6

5" × 12' 2.15

12" × 12" 0.94

As the face brick is bonded to the tile backing by a double header

bonding course, as shown on page 25, the amount of tile will have

to be reduced accordingly. For instance, if 12" × 12" tile are

used, the bonding course occurs every sixth course and one-sixth of

the tile should be deducted, but at the same time, there must be

added brick-size hollow tile at the rate of 12 to every 20 square

feet of wall surface for use behind the stretchers in the bonding

courses.

Or, if 5" × 12" tile are used, the bonding course occurs every

fifth course and one-fifth of the tile should be deducted, and

brick-size hollow tile at the rate of 12 to every 16 square feet of

wall surface should be added for use behind the stretchers in the

bonding courses. When the backing is 8 inches thick, an additional

course of brick-size tile should be calculated behind every bonding

course. If the brick-size tile cannot be obtained in the local

market, an equal number of common brick will answer the purpose

just as well. Two to three per cent should be added to all tile

quantities calculated, to provide for waste.

In giving the following examples of estimating quantities it is not

meant to indicate that each wall of the house is necessarily to be

estimated by itself, but simply to show the way of estimating any

extent of wall. Except in very elaborate and diverse elevations,

the best way is to figure on the total surface of the four sides in

one operation. This is the more easily done as, generally speaking,

opposite sides of the house are of like area.

A manual of face brick construction · 第 107 / 156 题