THE THERMO-ELECTRIC ELEMENTS.

In order to detect differences in temperature between the copper and

zinc walls, some system for measuring temperature differences between

these walls is essential. For this purpose we have found nothing that is

as practical as the system of iron-German-silver thermo-electric

elements originally introduced in this type of calorimeter by E. B.

Rosa, of the National Bureau of Standards, formerly professor of physics

at Wesleyan University. In these calorimeters the same principle,

therefore, has been applied, and it is necessary here only to give the

details of such changes in the construction of the elements, their

mounting, and their insulation as have been made as a result of

experience in constructing these calorimeters. An element consisting of

four pairs of junctions is shown in place as T-J in fig. 25.

One ever-present difficulty with the older form of element was the

tendency for the German-silver wires to slip out of the slots in which

they had been vigorously crowded in the hard maple spool. In thus

slipping out of the slots they came in contact with the metal thimble in

the zinc wall and thus produced a ground. In constructing the new

elements four pairs of iron-German-silver thermal junctions were made on

essentially the same plan as that previously described,[6] the only

modification being made in the spool. While the ends of the junctions

nearest the copper are exposed to the air so as to take up most rapidly

the temperature of the copper, it is somewhat difficult to expose the

ends of the junctions nearest the zinc and at the same time avoid

short-circuiting. The best procedure is to extend the rock maple spool

which passes clear through the ferule in the zinc wall and cut a wide

slot in the spool so as to expose the junctions to the air nearest the

ferule. By so doing the danger to the unprotected ends of the junctions

is much less. The two lead-wires of German silver can be carried through

the end of the spool and thus allow the insulation to be made much more

satisfactorily. In these calorimeters free use of these thermal

junctions has been made. In the chair calorimeter there are on the top

16 elements consisting of four junctions each, on the rear 18, on the

front 8, and on the bottom 13. The distribution of the elements is made

with due reference to the direction in which the heat is most directly

radiated and conducted from the surface of the body.

While the original iron-German-silver junctions have been retained in

two of these calorimeters for the practical reason that a large number

of these elements had been constructed beforehand, we believe it will be

more advantageous to use the copper-constantin couple, which has a

thermo-electric force of 40 microvolts per degree as against the 25 of

the iron-German-silver couple. It is planned to install the

copper-constantin junctions in the calorimeters now building.

Respiration Calorimeters for Studying the Respiratory Exchange and Energy Transformations of Man · 第 46 / 120 题