The sixth (a part of cam No. 5) is the second elevator cam, which

operates the second elevator arm by means of a roller following the

contour of this cam. This arm, to which the lever is fastened, lowers

the second elevator to receive the line of matrices at the transfer

position and then raises them to the distributor box.

The seventh is the pot pump cam and operates the pump lever. There

is a roller on this lever resting against the face of the cam. This

lever forces the metal into the mold cell as the cam revolves to

the low portion. The lever is forced down by a strong spring. The

new style pot pump lever is connected to its shaft and has a lever

extending into the column. It is pulled downward by a stiff coil

spring.

The eighth is the pot cam, which acts on the pot lever, forcing the

mouth of the pot forward against the mold. There are two shoes on

this cam. The first or short shoe is to cause the face alignment; the

second or long shoe is to lock the pot firmly against the mold before

the slug is cast. A roller is carried in the pot lever and follows

the contour of this cam and is the medium through which the above

lockup is accomplished.

The ninth is the mold slide cam and driving gear. The right side of

this gear is channeled out, and carries the mold slide lever roller

which operates the mold slide to advance the mold disk to a position

in which the lugs of the matrices are held in the groove of the mold

for alignment. It also returns the mold disk after the line has been

cast, advances it again to ejecting position, and returns it after

the slug is ejected. This gear also carries the pot return cam, which

withdraws the pot from the mold after the cast. It also carries the

ejector cam which engages the pawl on the ejector lever and moves it

forward, ejecting the slug from the mold.

The tenth cam operates the delivery slide and transfer cam roller

arms and causes these two parts to return to normal position after

their respective movements. The delivery slide cam roller rotates on

the outer surface, while the transfer slide cam roller acts on the

inner surface. This cam also retracts the ejector lever after the

slug has been ejected. The automatic safety and stopping pawls are

attached to this cam. They are operated by the transfer slide and the

delivery slide rollers. This cam really consists of two parts in

one, the outer cam controlling the return of the delivery slide and

the inner one controlling the return of the transfer slide lever.

The cams are all fastened together by four long bolts extending from

cam No. 2 and ending at cam No. 9. They are all keyed to the main

shaft and held in place by a set screw under cam No. 7. The cams can

be shifted a little sidewise but should set against a collar on the

left side of the main shaft under cam No. 2. Cam No. 10 is held in

place by a key on the shaft and a set nut and is kept from working

toward the left by a locating piece fastened to the main shaft.

The cams should be kept clean to prevent undue wear. Under ordinary

conditions, the cams should be cleaned once each week. This may be

accomplished by locking the controlling lever out so the cams will

continue to rotate. Then hold a rag against the surface of the cam.

A small amount of a mixture of gasoline and kerosene on the rag will

help to cut all dirt and grit loose from the cams, and leave the

surface in good condition and reduce the wear. Cams allowed to run

without being cleaned will wear very rapidly and soon cause much

trouble and expense.

FIRST ELEVATOR SLIDE GUIDE

The first elevator slide guide contains the intermediate bar and pawl

(assembled), adjusting screws for the same, first elevator jaw duplex

rail operating blocks, and the elevator transfer slide releasing

lever.

The height of the intermediate bar and pawl is adjusted by the

two small screws that pass through the top and touch the bar. The

purpose of the bar and pawl is to push down any spacebands that may

not have dropped to normal position as the line is carried from

casting position to the transfer. If the pawl was set too high, the

spacebands would strike the second elevator bar, and wear the lower

rail.

The bar should be set so that when the second elevator is seated

at transfer position, the pawl, when raised to its highest point,

will be in line with the bottom of the second elevator bar. This

adjustment is made with the two screws that pass through the slide

guide and touch the intermediate bar.

It is also necessary for both ends of the intermediate bar to be the

same height. After adjusting the pawl, turn the machine until the

transfer slide finger has entered the channel; lay a six-inch scale

flat on the first elevator jaws in line with the bar, but clearing

the pawl. Raise the first elevator slide by hand until the scale

touches the bar. Adjust the bar horizontal with the scale by the same

two screws that pass through top of the slide guide.

DUPLEX RAIL OPERATING BLOCKS

The first elevator jaw duplex rail operating blocks are fastened to

the slide guide adjusting strip and have a limited adjustment, but

when they are worn so they will not operate the rail properly, they

should be renewed.

RELEASING LEVER

The releasing lever is for the purpose of preventing the transfer of

a line in case the second elevator does not descend or seat properly.

The adjusting screw in the side of the second elevator lever should

raise the left end of the releasing lever 1/32 of an inch above the

block on the transfer slide when the second elevator is seated in

transfer position.

TRANSFER SLIDE

The transfer slide gets its motion from the transfer lever to which

it is connected by means of a link.

The transfer lever gets its action from the split transfer cam lever

and roller, which are held against cam No. 10 by a spring in the

column.

The slide should be adjusted to allow 5-9/16 inches from the

intermediate channel to slide finger. (Allow one inch more on 36-em

machines). This adjustment should be made with the machine in normal

position. Loosen the two screws on the split lever, move the slide

finger 5-9/16 inches from the channel, and hold; then move the

roller against the cam and tighten the screws. This adjustment is

necessary so that a 30-em line, which measures 5 inches, will clear

the transfer slide finger 5/32 of an inch. The last matrix is carried

13/32 of an inch inside the first elevator jaws. There will be a

clearance of 5/32 of an inch from the first matrix and the transfer

slide finger when the machine is in transfer position. Be sure the

transfer finger is not bent when measuring this distance.

The cut in the slide finger should be flush with the left end of

the second elevator bar plate, when it has transferred the line to

the second elevator. This adjustment is made by the screw in the

automatic safety pawl, which comes in contact with the buffer, on cam

No. 10.

With the machine in transfer position, the cam lever roller is

against the buffer in cam No. 10. The adjusting screw in the

automatic safety pawl, being against the inner end of buffer,

regulates the distance between the cut in the finger and second

elevator bar plate. This adjustment, when properly made, insures the

line being moved from the first to the second elevator. Turning the

adjusting screw to the right increases the distance between the slide

finger and the bar plate. Turning to the left decreases it.

The horizontal screw in the transfer slide should bank against the

buffer in the spaceband lever to allow ⅛ of an inch between the cut

in the slide finger and the spaceband lever pawl when the slide

finger and spaceband lever pawl are at their closest point during

transfer.

After the line has been transferred to the second elevator the

spacebands, not having combinations, remain in the transfer channels

and must be moved under the spaceband lever pawl so they can be

returned to spaceband box. When the transfer cam lever roller is at

the lowest part of cam No. 10, the adjusting screw in transfer slide,

coming in contact with the buffer in the spaceband lever, regulates

the distance between the cut in the slide finger and the bottom of

the slot in the spaceband lever pawl.

SPACEBAND LEVER

The spaceband lever gets its motion from the transfer lever, through

a turnbuckle which connects the transfer lever and the spaceband

lever. The purpose of this form of coupling, so threaded that when

connecting the two levers it may be turned to regulate the length

of the connected parts, is to adjust the spaceband lever so the

spaceband lever pawl will pass the highest point of the spaceband

box rails, properly bringing the spacebands into the box.

Before making the spaceband lever adjustment, make sure that the

transfer slide finger is properly adjusted. Then place the machine in

normal position.

Adjust the turnbuckle so the hook of the pawl passes to the right of

the highest point of the spaceband box rails not more than 1/16 of an

inch. If there is too much space between the end of the pawl and the

latch on the spaceband box, which is used as a lock, when recasting

30 ems the slide finger would move to the right against the line and

force the matrix from the inner end of the first elevator before the

pawl would come in contact with the latch. If the slide adjustments

are properly made, the turning of the turnbuckle will have no effect

in the adjustment of the slide finger.

SPACEBAND LEVER PAWL

The spaceband pawl is fastened to the spaceband lever by a pivot pin

and held in place by a bushing, which fits over the pin. The screw

which clamps the bushing to the pin extends downward through the top

of the lever. The pawl pulls the spacebands back into the box after

the transfer. The pawl should ride freely in the transfer channel,

its bearing being a pin screwed into the back side of the pawl. This

pin rides on the top of the transfer channel. The sidewise adjustment

of the pawl is made by loosening the screw in the top of the transfer

lever and allowing the machine to turn over for a few lines, the

pawl thus seating itself. The spaceband pawl is held down on the

transfer channel by a small spring. The tension of this spring should

be strong enough to hold the spacebands from slipping from under the

pawl.

MOLD SLIDE

The mold slide, which carries the mold disk and molds, moves in a

slideway at the right of the metal pot and gets its action from cam

No. 9, and the mold cam lever on which are assembled two rollers.

One roller is fastened to the lever by a screw and a washer, and is

seated in a depression in the rear end of the mold slide connecting

the mold slide with cam No. 9. The other roller has as its bearing

an adjustable eccentric pin fastened to the mold cam lever, and

follows the contour of the cam in the right side of cam No. 9.

When a line of matrices is in position in front of the mold, the

mold slide advances so that the lugs of the matrices will enter

the aligning grooves of the mold. This position is held until the

spacebands are driven up for justification and the line is raised

for alignment. The slide then comes forward a second time for final

lockup just as the metal pot locks against the back of the mold.

When the mold slide comes forward the first time there should be .010

of an inch space between the mold and the vise jaws or the line. This

space between the mold and the jaws is regulated by the eccentric pin

in the mold cam lever roller, and allows the proper justification and

alignment of the matrices before the final lockup.

During the alignment and during the first justification, the matrices

must be perfectly free, so that they may readjust themselves sidewise

in the line. Hence the importance of preventing the mold from

pressing forward against the matrices and spacebands at its first

movement.

If the slide advances too far forward the aligning groove of the

mold would engage the lugs of the matrices before the first elevator

jaws were seated properly on the vise cap, shearing the lugs of the

matrices. Or if the mold was forced to lockup tight against the line,

it would prevent justifying properly, causing hair lines to show

between the matrices or a squirt on the left-hand end. If there is

too much space between the mold and the jaws, when the first elevator

raises for alignment, the lugs of the matrices not being in the

aligning groove, would permit the line of matrices to raise to the

upper aligning groove of the mold, causing the line of matrices to

be cast on the raised position; or if the aligning groove did not

advance close to hold the lugs, there would be a small squirt.

The .010 of an inch adjustment also affects the lockup of the slide

at ejecting position. If there is a trifle more space between the

mold and the line than .010 of an inch, the mold will not seat

against the banking blocks at ejecting point. This will sometimes

allow the slug to twist slightly, causing it to be trimmed crooked.

To test this adjustment: Turn the casting mechanism until the first

elevator jaws are resting on the vise cap; place a pig of metal under

the head of the slide and on top of the vise automatic stop rod;

fold a piece of newspaper three thicknesses, or proof paper until it

measures about .010 of an inch; close the vise jaws; place the paper

between the mold and the vise jaws; turn the machine by hand until

the metal pot is just ready to move forward; pull up on the paper,

which should bind a trifle as it is being withdrawn. If the paper

does not bind or binds too tight it would show that the slide is out

of adjustment.

To make the slide adjustment, place the paper between the jaws and

the mold as in the test. Change the position of the mold slide by

moving the eccentric pin in the mold cam lever roller so that the

paper can be withdrawn, binding just a trifle. Moving the handle

forces the mold slide either forward or backward, as desired.

The mold slide moves in the slideway on a gib. There should be .007

of an inch play between the mold slide and the gib because the mold

slide will expand from the heat of the metal pot, but by having the

above mentioned play, it will not bind, and will slide in and out

freely.

This adjustment is made by the two square head screws under the gib

on which the slide moves. There is no gib on the late model machines,

and consequently no adjustment for the slideway.

As the mold slide advances, it slides up on the locking stud blocks

on the vise, raising the slide approximately .007 of an inch. The

screw beneath the mold disk guide on the mold gear arm should have a

little clearance above it when the slide is forward on the locking

stud blocks. There should be play enough to slip a sheet of paper

between the screw and the guide when the mold disk is forward on the

locking studs.

To remove a mold slide: Lower the vise to second position, disconnect

the mold slide, and take out the ejector lever link. Pull forward on

the slide and disk, assembled, and lift out.

MOLD DISK LOCKING STUDS AND BLOCKS

After the mold disk makes the one-quarter and three-quarter

revolutions, the mold slide advances and the mold disk locking studs

enter the locking stud blocks which are on the vise. This keeps the

disk in position until the slug has been cast or ejected, as the case

may be.

On old style machines the bushings are in the disk, and the studs are

in the blocks. On all the new machines the studs are in the disk and

each bushing and block is made in one piece. The blocks are held to

the vise by the screws and dowel pins that pass through the front of

the vise and screw into the blocks. The left-hand stud block on the

newer models is loose sidewise, which permits the studs to enter the

stud blocks with the minimum amount of wear to the parts.

The stud blocks can be renewed by taking the old ones off one at a

time and using the remaining block as a guide.

The studs should be kept lubricated with a little graphite and

grease. Too much will collect on the mold and get to the matrices.

EJECTOR SLIDE

The ejector slide is connected to the ejector lever, by means of

a link, and is located in the channel cut in the side of the mold

slide. It is operated by the ejector cam, which comes in contact with

the ejector lever pawl. The cam is held tight to cam No. 9 by means

of a screw and dowel pin. After the ejector lever is brought forward,

it is pushed back into position by cam No. 10 coming in contact with

a projection on the ejector lever. There is a buffer spring placed

on the ejector slide which prevents the slide falling forward with a

sudden jerk after the ejector lever has passed its center of gravity

and the slug has passed the resistance of the trimming knives. The

spring works on a rod which banks against the ejector blade guide. If

this spring is not functioning, the slug will be thrown out on the

floor.

EJECTOR BLADE

The blade is connected to the ejector slide by the pins that pass

through the holes in the blade, the pins being operated by the

springs, throw-out cam, and lever. The blade pushes the slug out of

the mold, between the trimming knives, into the chase channel.

When the ejector blade advances to the ejecting position the front

end should come flush with the bracket on the chase or galley. If

it advanced beyond, the slug would be pushed out of the galley to

the floor. If it does not advance flush, the slug not being pushed

all the way out, would be turned to the right by the slug lever. The

adjustment is made with the screw that passes through the ejector

lever pawl.

If the blade advances beyond the bracket, turn in the pawl screw and

raise the pawl. The higher the pawl is raised, the less distance the

slug advances.

On machines that have the inclined galley, adjust blade to come flush

with the bevel on the knife block liner.

EJECTOR GUIDE BLOCK

The outer end of the ejector blade is held in place and guided by the

ejector guide block which sets directly back of the flange of the

mold disk, and is held by two machine screws passing through each

end of the block into the mold slide. This guide holds the blade in

position so it will pass squarely through the mold. It also helps the

buffer spring to steady the forward motion of the ejector. The point

of contact of the ejector block with the ejector blade is made of

brass and is held against the blade by spring tension.

The ejector blade guide should be kept free from oil, dirt, and metal

shavings, as these impair the free working of the guide. The brass

strip should be replaced when worn. Loose screws or a worn brass

strip will cause slugs to be thrown out on the floor.

TO CHANGE AN EJECTOR BLADE

Push in on the starting and stopping lever; let the vise down to

first position; back the machine by pushing back on cam No. 1 until

the second elevator falls on the safety hook; turn the mold disk

until the slot is in front of the blade; push the ejector lever

forward; remove the blade by reaching the right-hand in alongside

the mold slide and grasp the releasing lever and draw it towards the

front. Change the blade for the size wanted, and then let machine

come to normal position. Be careful not to get a blade wider than

the slug to be cast or there is danger of damaging the liners, or

the mold will be damaged. A good plan is always to check up on the

ejector blade after changing the liners.

UNIVERSAL EJECTOR

The universal ejector consists of a series of blades, 5-points in

thickness, in 2-em units; as a rule the first, or lower blade is a

4-em, and then in 2-em units up to 30-ems pica. These unit blades

move between plates, which brace them firmly on both sides, making

them rigid and preventing the blade from bending.

The back end of the unit blades are fastened to ejector blade links

that move in grooves cut lengthwise of the slide. There is a link for

each unit blade and they terminate at the back end of the mold slide

in front of a groove milled across the slide. A movable controller

bar works in a groove in the ejector slide, moving up or down in the

groove, back of a lug on each of the blade links. When the ejector

lever forces the ejector slide forward, the controller bar in the

groove of the slide comes against the lugs of the ejector links

forcing the blades forward through the mold.

The blades are withdrawn by a lug on the ejector slide coming in

contact with the lugs on the links.

When desiring to change the length of the blade to be used, move the

ejector blade controlling lever handle up or down. This handle is

situated below the starting and stopping lever and is connected to

the controller bar by a screw link. Also connected to this handle is

a pica gauge which operates in a groove in the delivery channel.

Moving the handle up or down engages less or more blades, the length

being indicated on the pica gauge in the delivery channel.

To remove the mold slide on machines which have a universal ejector,

lower the vise to second position, set the ejector at 10 or 12 ems,

take out the ejector blade controller link which screws into the

controller link lift. This will permit the controller bar to drop

out. Disconnect the mold slide and take out the ejector lever link.

If the machine is connected up with the water for cooling the molds,

it will be necessary to disconnect the hose before taking out the

slide.

REMOVING A STUCK SLUG

When there is a slug stuck in the mold, allow the machine to come

to normal by backing the machine sufficiently to allow the ejector

lever pawl to be raised, draw back on the ejector lever until the

pawl clears the ejector cam. Pull out the starting lever allowing the

machine to come to normal. Open the vise and remove the slug from the

mold by loosening the mold cap screws. Do not drive a stuck slug out

with the ejector blade.

MOLD KNIFE

The mold or back knife trims the base of the slug and is fastened to

the mold slide arm, back of the mold disk. It is placed at an angle

of about 45 degrees and is held by two washers and two round-head

screws which pass through the slotted holes of the knife. It is also

held by two adjusting screws that set against the base so that the

knife will set squarely and press lightly against the mold as the

disk is turned from casting to the ejecting position. As the mold

passes in front of the knife, the slug should be trimmed type-high,

which is .918 of an inch.

The front of the mold disk, when turning, must be bearing against the

mold disk guide so as to keep the mold against the knife while the

slug is being trimmed. If the mold disk guide does not set snugly

against the disk, the disk will spring away from the knife and the

slug will be higher on one end than the other. The guide is adjusted

by loosening the screw which holds it to the mold slide and moving it

snugly against the mold disk. Do not set the guide tight enough to

bind and prevent the free turning of the disk.

It sometimes happens that a disk will bind at one or more places as

it is being turned. This is due to the disk becoming warped from

heat or some other cause. If it is only a slight bind it will not

interfere with the adjustment.

Whenever it is necessary to put on a new or resharpened mold knife,

or to adjust it, be sure the mold disk guide is bearing against the

rim of the mold disk. It is always better to remove the guide and

clean it as it must be perfectly clean when it seats against the

disk. Always have the knife away from the mold when seating the

guide. Tighten the hexagon head screw slightly and then tap the guide

until a slight pressure against the disk is secured. Turn the disk

by hand until an even pressure has been secured and then tighten the

hexagon head nut tight.

Place the mold knife on the knife seat; be sure the seat is clean,

for the least particle of dirt or metal will make it more difficult

to make the adjustment. Also the bottom of the mold must be perfectly

clean and free from all metal. Set the knife square with, but not

quite touching the mold. Tighten down on the two round-head screws,

then adjust with the two screws under the bottom of knife so that

mold will turn without binding. The left-hand end of the knife trims

the ends of the slugs; the center of the knife trims the center of

the slugs. Avoid excessive pressure on either side as the knife is so

shaped that the sharp edge should just touch the mold.

Linotype mechanism · 第 8 / 12 段