Kerma and Kerma Rate in Tissue for APRFR Exposure Conditions

--------------------------------------------------------------------

Routine Pulse Yield Maximum Pulse Yield

1.5 × 10¹⁷ Fissions 2.1 × 10¹⁷ Fissions

--------------------------------------------------------------------

Kerma in Tissue

(ergs/gm)

P1[5] 1.6 × 10⁸ 2.2 × 10⁸

P2 4.9 × 10⁷ 6.8 × 10⁷

P3 4.1 × 10⁵ 5.7 × 10⁵

Kerma Rate in Tissue

(ergs/gm/sec)

P1 3.5 × 10¹² 4.7 × 10¹²

P2 1.1 × 10¹² 1.5 × 10¹²

P3 8.8 × 10⁹ 1.2 × 10¹⁰

[5] P1: Center of Glory Hole; P2: Core Surface; P3: 1 Meter from Core

Center.

[Illustration]

[Illustration]

[Illustration]

[Illustration]

Table VII.

Army Pulse Radiation Facility · 第 12 / 22 题