In a Museum

_The Problem_

You are a curator working with the ancient coin collection of a large

museum. A donor has just given the museum a group of 50 gold coins

presumably about 1500 years old. After months of careful study, you have

satisfied yourself that most of those coins are genuine specimens of

that period. Judging from your experience, you decide that a small group

of five are definite forgeries.

However, there are three others that you suspect are also fakes, but you

are not quite certain. You know that both genuine minters and forgers

often tried to save money by diluting their gold with less expensive

metals such as silver and copper. Since the chances are slim that the

forger’s product has the same concentration of gold, silver, and copper

as the genuine coins, you realize that a chemical analysis would help

you decide if the doubtful pieces were real or fake.

An accurate chemical analysis would require a sample of such size that

the coin would be ruined as a museum specimen. You need an analytical

method that can be applied to an infinitesimal sample.

_The Solution_

You are not a scientist but you’ve heard about neutron activation

analysis. Therefore, you contact a radiochemist at a local university

who is an expert in this field.

He decides to use a sampling technique developed by scientists at

Brookhaven National Laboratory for sampling metal objects of

archaeological interest. You obtain from him a set of 50 quartz plates

that have been ground on one side. Following his instructions, you

carefully scrape away a small area on the edge of each coin. You then

rub each freshly cleaned area across the ground surface of one plate

leaving a minute streak of metal similar to a pencil mark.

At the scientist’s laboratory, each plate is carefully placed inside a

quartz tube. No attempt is made to weigh the tiny streak of metal since

you wish only to compare the ratios of the metal concentrations.

However, because the samples make a rather bulky package, the scientist

is concerned with the uniformity of the neutron flux that each sample

will “see”. He therefore also places in each tube an exactly equal

weight of a gold—silver—copper alloy wire (of known proportions) to act

as a standard neutron-flux monitor. The tubes are then sealed and taken

to a reactor to be irradiated for 12 hours.

After the samples are removed from the reactor, the scientist carefully

breaks open each of the quartz tubes and places the sample and the

standard piece of wire in separate numbered plastic capsules with lids.

For an accurate comparison, each capsule is prepared in the same manner.

About 4 hours after the samples are removed from the reactor, he begins

the radioactivity measurements.

The sample capsules are loaded into an automatic sample-changing

mechanism that places each one into an identical position above a

lithium-drifted germanium detector. (See the chapter beginning on page

19.) Gamma-ray spectra are collected all day, first from a sample, then

from its accompanying standard. Each count takes 2 minutes, and 3

minutes are required between counts for data printout and sample

changing. A typical gamma-ray spectrum looks like the one in the figure

on the next page. Notice that only gold (gold-198) and copper

(copper-64) show up in this short counting time. Later on, radioactivity

from silver (silver-110_m_) can be measured using a longer counting

time. This can be done because while the activation products from copper

and gold have relatively short half-lives (12.8 hours and 2.7 days,

respectively), that from silver has a half-life of 270 days. To increase

the sensitivity of the analysis for silver, the scientist repackages and

re-irradiates the samples and wires for 100 hours. Silver-110_m_ is one

of _two_ radioactive isotopes of silver that have the _same_ mass. In

this case, one has a higher energy than the other and decays in a

different way. This is known as an isomeric state and it occurs for many

other elements as well as for silver.

[Illustration: Graph: “Counts in one minute per 3.1 KeV channel” _vs_

“Channel”]

Element Counts Channel number

0.158 MsV Au-199 600 40

0.412 MeV Au-198 800 120

0.511 MeV Cu-64 50 150

0.676 MeV Au-198 40 205

(Values estimated from graph)

The spectrum obtained from a streak of metal on a quartz plate after a

3-hour exposure to neutrons in a reactor and a 6-hour delay before

counting. The activation products of gold and copper are obviously

present and are easily measured in only 1 minute.

[Illustration: Graph: “Counts per 100 minutes per 3.2 KeV channel” _vs_

“Channel number”]

Energy Counts Channel Number

0.445 MeV 230 130

0.657 MeV 1200 190

0.687 MeV 170 200

0.715 MeV 220 220

0.760 MeV 230 225

0.820 MeV 60 250

0.884 MeV 500 260

0.937 MeV 190 280

(Values are estimated from graph)

The spectrum obtained from the same streak of metal after re-exposure

to neutrons for 100 hours and a delay of approximately 2 months before

counting. Activation products from gold and copper have decayed away

and the gamma-ray spectrum of silver-110m is now observed. In this

case the sample is closer to the detector than for the earlier

measurement and the measurement takes 100 minutes.

Two months later, the scientist repeats the procedure of counting the

samples and standards, except that this time the plastic capsules are

closer to the detector, each count is for 100 minutes, and the sample

changer operates for about a week. A typical spectrum looks like that in

the figure on page 39.

The scientist can now compute ratios for the three elements in each

sample and compare them with the standard, but he decides that a

computer could do it faster and with fewer errors. The data collected

during the two series of counts are therefore sent to a data processing

center where, in a matter of minutes, a computer does the following for

each of 50 samples: