BOILER TUBES.

The following table gives the draught area and heating surface of the

various sized boiler tubes and flues:

----------+---------------+-------------+----------------+-------------+

| | | | No. of |

| | |Heating surface | tubes in 1 |

External |Draught area |Draught Area |in feet | sq. foot of |

Diameter. |in sq. inches. |in sq. feet. |per ft. of tube | draught |

| | |in length. | area. |

----------+---------------+-------------+----------------+-------------+

5/8 | ...... | ...... | .1636 | ..... |

¾ | ...... | ...... | .1963 | ..... |

1 | .575 | .0040 | .2618 | 250.0 |

1¼ | .968 | .0067 | .3272 | 149.3 |

1½ | 1.389 | .00964 | .3927 | 103.7 |

1¾ | 1.911 | .0133 | .4581 | 75.2 |

2 | 2.573 | .0179 | .5236 | 55.9 |

2¼ | 3.333 | .0231 | .5891 | 43.3 |

2½ | 4.083 | .0284 | .6545 | 35.2 |

2¾ | 5.027 | .0349 | .7200 | 28.7 |

3 | 6.070 | .0422 | .7854 | 23.7 |

3¼ | 7.116 | .0494 | .8508 | 20.2 |

3½ | 8.347 | .0580 | .9163 | 17.2 |

3¾ | 9.676 | .0672 | .9818 | 14.9 |

4 | 10.93 | .0759 | 1.0472 | 13.2 |

4½ | 14.05 | .0996 | 1.1781 | 10.2 |

5 | 17.35 | .1205 | 1.3090 | 8.3 |

6 | 25.25 | .1753 | 1.5708 | 5.7 |

7 | 34.94 | .2426 | 1.8326 | 4.1 |

8 | 46.20 | .3208 | 2.0944 | 3.1 |

9 | 58.63 | .4072 | 2.3562 | 2.5 |

10 | 72.23 | .5016 | 2.6180 | 2.0 |

----------+---------------+-------------+----------------+-------------+

Scientific American Supplement, No. 467, December 13, 1884 · 第 19 / 76 题