CHAPTER XVII

Mr. Allen’s Invention of his Boiler. Exhibition at the Fair of the

American Institute in 1870.

At that time the “Field boiler tubes” were attracting considerable

attention in London. These were designed to prevent the water from

being lifted from the closed bottom of vertical tubes over the fire,

which would cause them to be burned out. The Field tubes were smaller

internal tubes, provided at the upper end with three wings which

centered them in the middle of the external tubes, in which they

reached nearly to the bottom. They were made slightly bell-mouthed

at the top. The circulation was down the internal tube and upwards,

through the annular space. The bell mouth prevented these currents from

interfering with each other. One morning Mr. Allen said to me that

he had an idea that by inclining the tubes at a small angle from the

vertical a better circulation would be got than in the Field tubes.

He thought the steam as fast as formed would all go to the upper side

of the inclined tubes, and would rush up along that surface without

driving the water before it, and so the water would always be at the

bottom of the tube, no matter how hard the boiler was fired. I was

struck with the idea and determined to test it. I got the largest

test-tube I could find, 1¹⁄₄ inches in diameter and 15 inches long, and

set it in an adjustable support, and applied the flame of four Bunsen

burners, bunched together, at the bottom. In a vertical position the

water was instantly thrown clean out of the tube. At about the angle

of 20 degrees Mr. Allen’s idea was completely realized. The bubbles of

steam united in a continuous stream on the upper side and rushed up

with no water before them. With the most rapid generation of steam the

water remained solid at the bottom of the tube. The sight was a very

interesting one. I reasoned that if this satisfactory result was got

under a short column of water, and only the pressure of the atmosphere

and in a small tube, it could certainly be relied upon under a column

of water several times longer, under a pressure of several atmospheres

and in a much larger tube. The greater the pressure the smaller the

bubbles of steam would be. Those formed under one atmosphere were about

as large as kidney beans.

Mr. Smith was anxious to have us exhibit the engine at the Fair of the

American Institute in New York in the fall of 1870. This Institute was

then at the height of its usefulness, and its annual fairs were crowded

with exhibits and attracted wide attention. Mr. Allen and I consulted

about it, and on account of the liability of getting more hot water

than steam from the queer boilers that might be exhibited, we agreed

that, as the engine would have to be tested for economy, it would not

be safe to exhibit unless we could make a boiler according to Mr.

Allen’s plan to supply the steam. With this boiler we could certainly

get dry steam, and felt confident of getting it superheated.

Our recommendation to that effect was adopted, and we prepared to

exhibit two engines, one of them 16 inches diameter of cylinder by

30 inches stroke to make 150 revolutions per minute, and the other 6

inches in diameter by 12 inches stroke to make 300 revolutions per

minute, and a boiler. We also made to drive our own shop, to take the

place of the portable engine and boiler, an engine of the smaller size

above named, except that the cylinder was, by thickening its walls,

made 5 inches in diameter only. This was because this size would be

ample for the power we required, and I would be able to show the effect

of inertia of the heavy reciprocating parts in producing smooth and

silent running, much better than with a 6-inch cylinder, which would

have about 50 per cent. larger area with no greater weight in the

reciprocating parts, except only in the piston. This exhibition, as we

shall see, became of great importance. We made also an Allen boiler for

ourselves, of four sections; really, as it proved, three or four times

as large as we needed, but we could not well make it smaller.

This exhibition at the American Institute was in every respect a great

success, not a drawback of any kind about it. The little engine was

used by Merrill & Sons to drive their exhibit of forging machinery,

hammers and drops. The large engine gave motion to a miscellaneous

exhibit of machinery in motion. The exhibition of machinery in motion

closed each day for an hour from 12 to 1, and again from 6 to 7, but

I ran these engines continuously from 9 A.M. to 10 P.M., to show that

high speed asked no favors. There were five boilers, including our own,

from the start. The other four were smaller than ours. Another boiler,

the largest of all except ours, was started later, as will be told.

Ours had a brick flue and chimney, but only 30 feet high. Those of the

others were iron. There were a number of other engines and pumps and

pulsometers, all steam eaters.

It was found impossible to keep up steam. It fell to half pressure

every day before stopping time came.

One morning, about a week after the opening, on my arrival my friend

Mr. Lee, who was superintendent of the machinery department, came to me

and said, “Do you know what they are all saying about here?” “No,” I

replied. “Well,” said he, “you ought to know. It is that your engines

use all the steam, and your boiler does not make any, and that is

where all the trouble is.” I replied: “I am ready for them. You see

that valve up there. I put it in expressly to meet whatever questions

might arise. By closing it I can shut my system off from the general

steam connections and run my two engines from my own boiler, and will

try to get on without their assistance.” So a ladder was brought and

I went up and shut the valve. Directly my pressure rose to 70 pounds,

the pressure allowed; my automatic damper closed as nearly as it was

permitted to do, and the steam began to blow off. To prevent this, the

fireman had to set his door a little way open, and in this condition we

ran all day. In the rest of the show the steam ran down until at noon

there was barely 15 pounds pressure, but the wrath of the exhibitors of

machinery driven by other engines was blowing off. After the noon hour

the additional boiler was started and helped them a good deal, so that,

starting with 70 pounds at 1 o’clock, at 5 o’clock they still had 25

pounds pressure.

Mr. Lee asked me several times during the day to open the valve and

I refused to do it. Finally, at about 5 o’clock, he said to me, “If

you don’t open that valve, I shall.” “Well,” said I, “there will be a

number of the managers of the Institute here at this hour, I presume,

and if you will send for them and have them come here and see the state

of the case for themselves then I will open the valve.” So this was

done. Half a dozen of these gentlemen came and made an inspection of

the boilers and said to me: “We are quite satisfied. It is evident that

you have been supplying most of the steam and using very little.” So I

opened the valve and there was no further trouble. The assistance of

the large boiler added that day prevented any serious fall of pressure

afterwards.

A few days after the above incident a committee of the managers waited

on me and said: “We have heretofore had a good deal of trouble with

our steam supply, and would like next year to have a boiler that we

can rely upon. What will you ask to leave this boiler here for our use

next season?” I agreed with them for three hundred dollars, and so the

boiler remained for the next exhibition, when there will be something

more to be said about it and views of it will be shown. That winter

Barnum wintered his animals in that building, and paid me three hundred

dollars more for the use of the boiler to warm it. In my ignorance of

business these items of good luck came in very handy. Mr. Allen said he

never heard of a new thing so successful from the start.

The remark respecting my exhibit of engines and boiler at the fair of

the American Institute in 1870, that there was not a drawback of any

kind about it, must, however, be qualified in one respect. I was not

able to run my 16×30 engine at the speed of 150 revolutions per minute,

as I had intended.

A blunder had been made in the size of the driven pulley on the line of

shafting. It was smaller than specified, because the contractor for the

shafting put on a pulley he had, and this was not observed till we were

running, when it was too late to change it. The exhibitors of machinery

in motion all complained that their machines were running too fast, and

after two or three days the directors ordered me to reduce the speed

of my engine to 125 revolutions per minute, at which speed it was run

through the rest of the fair. I was much disappointed, but consoled

myself with thinking that perhaps this speed would please the general

public better than the higher one, the engine even then being three or

four times too large for its work.

The boiler gave me at the engine steam superheated 23 degrees all

the time. This I proved by transposing the thermometers. I had two

thermometers, duplicates, one on the steam-chest and the other on the

first boiler drum, in which the steam was not superheated. The former

indicated 23 degrees higher temperature. When these were exchanged the

same difference continued to be shown.

I was greatly interested in observing in my own and other engines the

relative amounts of initial cylinder condensation, as this was shown in

the steam blown from the indicator stop-cocks. I had one of these on my

steam-chest, and the steam blown from this was not visible until three

or four inches above it. That blown from the stop-cocks on my cylinder

had a very little tinge of white, showing the superheating to have been

lost and a slight initial condensation to take place. As the piston

advanced, the blowing steam became invisible, showing re-evaporation,

through the falling of the boiling-point on the expansion.

On other engines, of which several were exhibited, the observation

showed large amounts of initial condensation. From one of them I

remember the blowing steam looked like a white painted stick.

I observed that the steam only lost three degrees of its superheat in

passing through 25 feet of 6-inch pipe from the boiler to the engine.

For this comparison I placed a thermometer on the second steam drum, in

which the steam was superheated, where it showed about 26 degrees of

superheat. This measured the rate at which the heat was lost through

the felt covering of the pipe, and suggested an excellent method of

comparing the protective value of different coverings under absolutely

the same conditions.

The superheating of the steam for our own engine was not affected by

the connection of our steam-pipe with those of the other engines.

The explanation of this phenomenon seemed to be that as our boiler

generated far more steam than our own engines required, the current

was always _from_ our pipe into the connected pipes.

[Illustration: Diagram from Allen Engine, back end of cylinder, at Fair

of American Institute, 1870.]

I was here first made alive to the enormous waste of steam in the

feed-pumps, a separate one for every boiler, including our own. In

these the steam has to follow full stroke, at a pressure sufficient, on

the larger area of the steam piston, to overcome the pressure in the

boiler. Moreover, the extreme heat interval between the temperatures

of the entering and the exhaust steam and the slow motion, permitting

the walls of cylinder, heads and piston to be cooled very deeply by the

exhaust, produces the condensation of probably from five to ten times

as much steam as is usefully employed, differing according to the rate

of piston motion. I began to rather admire the practice of the English,

who knew nothing about boiler feed-pumps, except those on the engine,

and I certainly wonder that the genius did not arise long before he

did, who first thought of exhausting the feed-pump into the feed-water

under atmospheric pressure only, so returning to the boiler all the

heat received in the pump that is not converted into the work of

overcoming the boiler pressure and the atmospheric resistance or lost

in external radiation.

The above diagram represents the performance of this engine in its

regular work. It shows distinctly the compression curve, the points

of cut-off and release, and the back pressure required to expel the

exhaust. It will be seen that the expansion fell to 5 pounds below

the atmosphere. I have added to it a line representing the waste room

in ports and clearance, and the theoretical expansion curve plotted

according to the law of Mariotte, showing the expansion terminating 2.5

pounds above this curve, from the re-evaporation already noted and the

heat abandoned by the steam as the pressure fell.

After the close of the fair this engine was run on several days,

under a variety of loads applied by a Prony brake, in the presence

of a number of engineers and others who had been invited to witness

the trials. Of the diagrams taken on these trials, I find that I have

preserved only the two here shown, namely, a single friction diagram

from the back end of the cylinder, on a scale of 20 pounds to the inch,

and a diagram showing large power, taken from the front or crank end,

on a scale of 24 pounds to the inch. The former shows the trifling loss

from friction in this engine. I have measured this card, and find the

mean effective pressure, or difference between the areas showing the

excess of the forward over the back pressure, to be 1.1 pounds on the

square inch, which, assuming the opposite card to be equal with it, was

the friction of the engine. The exhaust line shows the power required

to reverse the direction of motion of the exhaust, which at the end of

the stroke was rushing back into the cylinder.

The latter is especially interesting as showing the identity of the

expansion curve with the theoretical, three points on which are marked

by the crosses. The sharp reaction of the indicator while the crank was

passing the dead center will also be observed.

After this trial I made a careful comparison of the diagrams taken

under the different loads with the friction diagrams, and found the

uniform results to be that the friction diagrams subtracted from the

diagrams taken under the load left in each case, of six different

loads, exactly the same effective work done that was shown by the brake.

[Illustration: Friction Diagram from Allen Engine at Fair of American

Institute, 1870.]

[Illustration: Diagram from Allen Engine, Fair of American Institute,

1870, cutting off at ¹⁄₄ stroke.]

From this I concluded that in these engines the use of the friction

brake is unnecessary; the friction is sensibly the same under all

loads, and the friction diagram only needs to be subtracted to learn

from the diagram the amount of effective work done.

The verdict of the judges, President Barnard of Columbia College,

Thomas J. Sloane, the proposer of the gimlet-pointed wood screw, now

in universal use, in place of the flat-ended screws formerly used, and

inventor of the special machinery required for their manufacture, and

Robert Weir, engineer in the Croton Aqueduct department, may be summed

up in the single expression from their report, “The performance of this

engine is without precedent.” For its success I was largely indebted,

first, to the remarkable circulation and steam-generating power of the

boiler, and, second, to the superheating of the steam in the second

drum.