1. Roll each bougie up in a piece of asbestos cloth, secure the ends of

the cloth with a few turns of copper wire, and place inside the muffle

(a small muffle 76x88x163 mm. will hold perhaps four small filter

candles).

2. Light the gas and raise the contents of the muffle to a white heat;

maintain this temperature for five minutes.

3. Extinguish the gas, and when the muffle has become quite cold remove

the filter candles, and store them (without removing the asbestos

wrappings) in sterile metal boxes.

NOTE.--The too rapid cooling of the candles, such as takes

place if they are removed from the muffle before it has

cooled down to the room temperature, may give rise to

microscopic cracks and flaws which will effectually destroy

their efficiency.

_Hot Air._--Hot air at 150 deg. C. destroys all bacteria, spores, etc:, in

about thirty minutes; a momentary exposure to a temperature of 175 deg. to

180 deg. C. will effect the same result and offers the more convenient

method of sterilisation. This method is only applicable to glass and

metallic substances, and the small bulk of cotton-wool comprised in the

test-tube plugs, etc. Large masses of fabric are not effectually

sterilised by dry heat--short of charring--as its power of penetration

is not great.

Sterilisation by hot air is effected in the hot-air oven (Fig. 18). This

is a rectangular, double-walled metal box, mounted on a stand and heated

from below by a large Bunsen burner. The interior of the oven is

provided with loose shelves upon which the articles to be sterilised are

arranged, either singly or packed in square wire baskets or crates, kept

specially for this purpose. One of the sides is hinged to form a door.

The central portion of the metal bottom, on which the Bunsen flame would

play, is cut away, and replaced by firebrick plates, which slide in

metal grooves and are easily replaced when broken or worn out. The top

of the oven is provided with a perforated ventilator slide and two

tubulures, the one for the reception of a centigrade thermometer

graduated to 200 deg. or 250 deg. C., the other for a thermo-regulator. An

ordinary mercurial thermo-regulator may be used but it is preferable to

employ a regulating capsule of the Hearson type (see p. 219) with a

spring arm adjusted to the lever so that when the boiling-point of the

capsule (e. g., 175 deg. C.) is reached the gas supply is absolutely cut

off and the jet cannot again be lighted until the spring-arm has been

readjusted by hand. The thermo-regulator is by no means a necessity, and

may be replaced by a large bore thermometer with a sliding platinum

point, connected with an electric bell, which can be easily adjusted to

ring at any given temperature. Even if the steriliser is provided with

the capsule regulator above described the contact thermometer should

also be fitted.

[Illustration: FIG. 26.--Hot-air oven.]

TO USE THE HOT-AIR OVEN.--

1. Place the crates of test-tubes, metal cases containing plates and

pipettes, loose apparatus, etc., inside the oven, taking particular care

that none of the cotton-wool plugs are in contact with the walls,

otherwise the heat transmitted by the metal will char or even flame

them.

To prepare a wire crate for the reception of test-tubes,

etc., cover the bottom with a layer of thick asbestos cloth;

or take some asbestos fibre, moisten it with a little water

and knead it into a paste; plaster the paste over the bottom

of the crate, working it into the meshes and smoothing the

surface by means of a pestle. When several crates have been

thus treated, place them inside the hot-air oven, close the

door, open the ventilating slide, light the gas, and run the

temperature of the interior up to about 160 deg. C. After an

interval of ten minutes extinguish the gas, open the oven

door, and allow the contents to cool. The asbestos now forms

a smooth, dry, spongy layer over the bottom, which will last

many months before needing renewal, and will considerably

diminish the loss of tubes from breakage.

Copper cylinders and large test-tubes intended for the

reception of pipettes are prepared in a similar manner, in

order to protect the points of these articles from injury.

2. Close the oven door, and open the ventilating slide, in order that

any moisture left in the tubes, etc., may escape; light the gas below;

set the electric alarm to ring at 100 deg. C.

3. When the temperature of the oven has reached 100 deg. C., close the

ventilating slide; reset the alarm to ring at 175 deg. C.

4. Run the temperature up to 175 deg. C.

5. Extinguish the gas at once, and allow the apparatus to cool.

6. When the temperature of the interior, as recorded by the thermometer,

has fallen to 60 deg. C.--_but not before_--the door may be opened and

the sterile articles removed and stored away.

NOTE.--Neglect of this precautionary cooling of the oven to

60 deg. C. will result in numerous cracked and broken tubes.

On removal from the oven, the cotton-wool plugs will probably be

slightly brown in colour.

Metal instruments, such as knives, scissors, and forceps, may be

sterilised in the hot-air oven as described above, but exposure to 175 deg.

C. is likely to seriously affect the temper of the steel and certainly

blunts the cutting edges. If, however, it is desired to sterilise

surgical instruments by hot air, they should be packed in a metal box,

or boxes, and heated to 130 deg. C. and retained at that temperature for

about thirty minutes.

~Moist Heat.~--_Water at 56 deg. C._--This temperature, if maintained for

thirty minutes, is sufficient to destroy the vegetative forms of

bacteria, but has practically no effect on spores. Its use is limited to

the sterilisation of such albuminous "fluid" media as would coagulate at

a higher temperature.

METHOD.--

1. Fit up a water-bath, heated by a Bunsen flame which is controlled by

a thermo-regulator, so that the temperature of the water remains at 56

deg. C.

2. Immerse the tubes or flasks containing the albuminous fluid in the

water-bath so that the upper level of such fluid is at least 2 cm. below

the level of the water. (The temperature of the bath will now fall

somewhat, but after a few minutes will again rise to 56 deg. C).

3. After thirty minutes' exposure to 56 deg. C, extinguish the gas, remove

the tubes or flasks from the bath, and subject them to the action of

running water so that their contents are rapidly cooled.

4. The vegetative forms of bacteria present in the liquid being killed,

stand it for twenty-four hours in a cool, dark place; at the end of that

time some at least of such spores as may be present will have germinated

and assumed the vegetative form.

5. Destroy these new vegetative forms by a similar exposure to 56 deg. C.

on the second day, whilst others, of slower germination, may be caught on

the third day, and so on.

6. In order to ensure thorough sterilisation, repeat the process on each

of six successive days.

This method of exposing liquids to a temperature of 56 deg. C. in a

water-bath for half an hour on each of six successive days is termed

_fractional sterilisation_.

_Water at 100 deg. C._ destroys the vegetative forms of bacteria almost

instantaneously, and spores in from five to fifteen minutes. This method

of sterilisation is applicable to the metal instruments, such as knives,

forceps, etc., used in animal experiments; syringes, rubber corks,

rubber and glass tubing, and other small apparatus, and is effected in

what is usually spoken of as the "water steriliser" (Fig. 27).

[Illustration: FIG. 27.--Water sterilizer.]

This is a rectangular copper box, 26 cm. long, 18 cm. wide, and 12 cm.

deep, mounted on legs, heated from below by a Bunsen or radial gas

burner, and containing a movable copper wire tray, 2 cm. smaller in

every dimension than the steriliser itself, and provided with handles.

The top of the steriliser is hinged to form a lid.

METHOD.--

1. Place the instruments, etc., to be sterilised inside the copper

basket, and replace the basket in the steriliser.

2. Pour a sufficient quantity of water into the steriliser, shut down

the lid, and light the gas below.

[Illustration: FIG. 28.--Koch's steriliser.]

[Illustration: FIG. 29.--Arnold's steriliser.]

3. After the water has boiled and steam has been issuing from beneath

the lid for at least ten minutes, extinguish the gas, open the lid, and

lift out the wire basket by its handles and rest it diagonally on the

walls of the steriliser; the contained instruments, etc., are now

sterile and ready for use.

4. After use, or when accidentally contaminated, replace the instruments

in the basket and return that to the steriliser; completely disinfect by

a further boiling for fifteen minutes.

5. After disinfection, and whilst still hot, take out the instruments,

dry carefully and at once, and return them to their store cases.

_Streaming steam_--i. e., steam at 100 deg. C.--destroys the vegetative

forms of bacteria in from fifteen to twenty minutes, and the sporing

forms in from one to two hours. This method is chiefly used for the

sterilisation of the various nutrient media intended for the cultivation

of bacteria, and is carried out in a steam kettle of special

construction, known as Koch's steam steriliser (Fig. 28) or in one of

its many modifications, the most efficient of which is Arnold's (Fig.

29).

The steam steriliser in its simplest form consists of a tall tinned-iron

or copper cylindrical vessel, divided into two unequal parts by a

movable perforated metal diaphragm, the lower, smaller portion serving

for a water reservoir, and the upper part for the reception of wire

baskets containing the articles to be sterilised. The vessel is closed

by a loose conical lid, provided with handles, and perforated at its

apex by a tubulure; it is mounted on a tripod stand and heated from

below by a Bunsen burner. The more elaborate steriliser is cased with

felt or asbestos board, and provided with a water gauge, also a tap for

emptying the water compartment.

TO USE THE STEAM STERILISER.--

1. Fill the water compartment to the level of the perforated diaphragm,

place the lid in position, and light the Bunsen burner.

2. After the water has boiled, allow sufficient time to elapse for steam

to replace the air in the sterilising compartment, as shown by the steam

issuing in a steady, continuous stream from the tubulure in the lid.

3. Remove the lid, quickly lower the wire basket containing media tubes,

etc., into the sterilising compartment until it rests on the diaphragm,

and replace the lid.

4. After an interval of twenty minutes in the case of fluid media, or

thirty minutes in the case of solid media, take off the lid and remove

the basket with its contents.

5. Now, but not before, extinguish the gas.

NOTE.--After removing tubes, flasks, etc., from the steam

steriliser, they should be at once separated freely in order

to prevent moisture condensing upon the cotton-wool plugs

and soaking through into the interior of the tubes.

This treatment will destroy any vegetative forms of bacteria; during the

hours of cooling any spores present will germinate, and the young

organisms will be destroyed by repeating the process twenty-four hours

later; a third sterilisation after a similar interval makes assurance

doubly sure.

The method of sterilising by exposure to streaming steam at 100 deg. C.

for twenty minutes on each of three consecutive days is termed

_discontinuous_ or _intermittent sterilisation_.

Exposure to steam at 100 deg. C. for a period of one or two hours, or

_continuous sterilisation_, cannot always be depended upon and is

therefore not to be recommended.

_Superheated steam_--i. e., steam under pressure (see

Pressure-temperature table, Appendix, page 500) in sealed vessels at a

temperature of 115 deg. C.--will destroy both the vegetative and the

sporing forms of bacteria within fifteen minutes; if the pressure is

increased, and the temperature raised to 120 deg. C., the same end is

attained in ten minutes. This method was formerly employed for the

sterilisation of media (and indeed is so used in some laboratories

still), but most workers now realise that media subjected to this high

temperature undergo hydrolytic changes which render them unsuitable for

the cultivation of the more delicate micro-organisms. The use of

superheated steam should be restricted almost entirely to the

disinfection of such contaminated articles, old cultivations, etc., as

cannot be dealt with by dry heat or the actual furnace. Sterilisation

by means of superheated steam is carried out in a special

boiler--Chamberland's autoclave (Fig. 30). The autoclave consists of a

stout copper cylinder, provided with a copper or gun-metal lid, which

is secured in place by means of bolts and thumbscrews, the joint between

the cylinder and its lid being hermetically sealed by the interposition

of a rubber washer. The cover is perforated for a branched tube carrying

a vent cock, a manometer, and a safety valve. The copper boiler is

mounted in the upper half of a cylindrical sheet-iron case--two

concentric circular rows of Bunsen burners, each circle having an

independent gas-supply, occupying the lower half. In the interior of the

boiler is a large movable wire basket, mounted on legs, for the reception

of the articles to be sterilised.

TO USE THE AUTOCLAVE.--

1. Pack the articles to be sterilised in the wire basket.

2. Run water into the boiler to the level of the bottom of the basket;

also fill the contained flasks and tubes with water.

3. See that the rubber washer is in position, then replace the cover and

fasten it tightly on to the autoclave by means of the thumbscrews.

4. Open the vent cock and light both rings of burners.

5. When steam is issuing in a steady, continuous stream from the vent

tube, shut off the vent cock and extinguish the outer ring of gas

burners.

6. Wait until the index of the manometer records a temperature of 120 deg.

C., then regulate the gas and the spring safety valve in such a manner

that this temperature is just maintained, and leave it thus for twenty

minutes. In the more expensive patterns of autoclave this regulation of

the safety valve is carried out automatically, the manometer being

fitted with an adjustable pointer which can be set to any required

pressure-temperature and so arranged that when the index of the

manometer coincides with the adjustable hand the safety valve is opened.

7. Extinguish the gas and allow the manometer index to fall to zero.

[Illustration: FIG. 30.--Chamberland's Autoclave.]

8. Now open the vent cock slowly, and allow the internal pressure to

adjust itself to that of the atmosphere.

9. Remove the cover and take out the sterilised contents.

~Sterilisation Periods.~--An exceedingly useful device for the timing of

sterilisation periods (and indeed for many other operations in the

laboratory) is the

ELECTRIC SIGNAL TIMING CLOCK.

This is a clock of American type in which the face is surrounded by a

metal plate having a series of 60 holes at equal distances apart,

corresponding to the minutes on the dial. This plate is connected with

one of the poles of a dry battery, the other pole of which is connected

to the metal case of the clock for the purpose of actuating an ordinary

magnet alarm bell. In the centre of each of the holes in the plate a

metal rod is fixed, which then passes through an insulating ring and

projects inside the clock face, where it makes contact with the hour

hand. The clock is mounted on a heavy base, with a key-board containing

20 numbered plugs. If one of the plugs is inserted in a hole in the

plate it makes contact with the rod, and when the hour hand of the clock

touches the other end the circuit is completed and the bell starts

ringing. The period of this friction contact is approximately 20

seconds. The clock can therefore be used for electrically noting the

periods of time from one minute by multiples of one minute up to one

hour.

[Illustration: FIG. 31.--Electric signal timing clock.]

~Filtration.~--(a) _Cotton-wool Filter._--Practically the only method in

use in the laboratory for the sterilisation of air or of a gas is by

filtration through dry cotton-wool or glass-wool, the fibres of which

entangle the micro-organisms and prevent their passage.

Perhaps the best example of such a filter is the cotton-wool plug which

closes the mouth of a culture tube. Not only does ordinary diffusion

take place through it, but if a tube plugged in the usual manner with

cotton-wool is removed from the hot incubator, the temperature of the

contained air rapidly falls to that of the laboratory, and a partial

vacuum is formed; air passes into the tube, through the cotton-wool

plug, to restore the equilibrium, and, so long as the plug remains dry,

in a germ-free condition. If, however, the plug becomes moist, either by

absorption from the atmosphere, or from liquids coming into contact with

it, micro-organisms (especially the mould fungi) commence to multiply,

and the long thread forms rapidly penetrate the substance of the plug,

and gain access to and contaminate the interior of the tube.

[Illustration: FIG. 32.--Cotton-wool air filter.]

METHOD.--

If it is desired to sterilise gases before admission to a vessel

containing a pure cultivation of a micro-organism, as, for instance,

when forcing a current of oxygen over or through a broth cultivation of

the diphtheria bacillus, this can be readily effected as follows:

1. Take a length of glass tubing of, say, 1.5 cm. diameter, in the

centre of which a bulb has been blown, fill the bulb with dry

cotton-wool (Fig. 32), wrap a layer of cotton-wool around each end of

the tube, and secure in position with a turn of thin copper wire or

string; then sterilise the piece of apparatus in the hot-air oven.

2. Prepare the cultivation in a Ruffer or Woodhead flask (Fig. 33) the

inlet tube of which has its free extremity enveloped in a layer of

cotton-wool, secured by thread or wire, whilst the exit tube is plugged

in the usual manner.

[Illustration: FIG. 33.--Ruffer's flask.]

3. Sterilise a short length of rubber tubing by boiling. Transfer it

from the boiling water to a beaker of absolute alcohol.

4. When all is ready remove the rubber tube from the alcohol by means of

a pair of forceps, drain it thoroughly, and pass through the flame of a

Bunsen burner to burn off the last traces of alcohol.

5. Remove the cotton-wool wraps from the entry tube of the flask and

from one end of the filter tube and rapidly couple them up by means of

the sterile rubber tubing.

6. Connect the other end of the bulb tube with the delivery tube from

the gas reservoir.

The gas in its passage through the dry sterile cotton-wool in the bulb

of the filter tube will be freed from any contained micro-organisms and

will enter the flask in a sterile condition.

(b) _Porcelain Filter._--The sterilisation of liquids by filtration is

effected by passing them through a cylindrical vessel, closed at one end

like a test-tube, and made either of porous "biscuit" porcelain,

hard-burnt and unglazed (Chamberland system), or of Kieselguhr, a fine

diatomaceous earth (Berkefeld system), and termed a "bougie" or "candle"

(Fig. 34).

NOTE.--In selecting candles for use in the laboratory avoid

those with metal fittings, since during sterilisation cracks

develop at the junction of the metal and the siliceous

material owing to the unequal expansion.

In this method the bacteria are retained in the pores of the filter

while the liquid passes through in a germ-free condition.

It is obvious that to be effective the pores of the filter must be

extremely minute, and therefore the rate of filtration will usually be

slow. Chamberland filter candles possess finer channels than Berkefeld

candles and consequently filter much more slowly. To overcome this

disadvantage, either aspiration or pressure, or a combination of these

two forces, may be employed to hasten the process.

Doultons white porcelain filters it may be noted are as efficient as the

Chamberland candles and filter rather more rapidly.

_Apparatus Required._--

1. Separatory funnel containing the unfiltered fluid.

2. Sterile filter candle (Fig. 34), the open end fitted with a rubber

stopper (Fig. 34, a) perforated to receive the delivery tube of the

separatory funnel, and its neck passed through a large rubber washer

(Fig. 34, b) which fits the mouth of the filter flask.

3. Sterile filter flask of suitable size, for the reception of the

filtered fluid, its mouth closed by a cotton-wool plug.

4. Water injector Sprengel (see Fig. 38, c) pump, or Geryk's pump (an

air pump on the hydraulic principle, sealed by means of low

vapor-tension oil, Fig. 35).

If this latter is employed, a Wulff's bottle, fitted as a wash-bottle

and containing sulphuric acid, must be interposed between the filter

flask and the pump, in order to prevent moist air reaching the oil in

the pump.

5. Air filter (_vide_ page 40) sterilised.

6. Pressure tubing.

7. Screw clamps (Fig. 36).

METHOD.--

1. Couple the exhaust pipe of the suction pump with the lateral tube of

the filter flask (first removing the cotton-wool plug from this latter),

by means of pressure tubing, interposing, if necessary, the wash-bottle

of sulphuric acid.

[Illustration: FIG. 34.--Porcelain filter candle.]

[Illustration: FIG. 35.--Geryk air pump.]

2. Remove the cotton-wool plug from the neck of the filter flask and

adjust the porcelain candle in its place.

[Illustration: FIG. 36.--Screw clamps.]

3. Attach the nozzle of the separatory funnel to the filter candle by

means of the perforated rubber stopper (Fig. 37).

[Illustration: FIG. 37.--Apparatus arranged for filtering--aspiration.]

4. Open the tap of the funnel, and exhaust the air from the filter flask

and wash-bottle; maintain the vacuum until the filtration is complete.

5. When the filtration is completed close the tap of the funnel; adjust

a screw clamp to the pressure tubing attached to the lateral branch of

the filter flask; screw it up tightly, and disconnect the acid

wash-bottle.

6. Attach the air filter to the open end of the pressure tubing; open

the screw clamp gradually, and allow filtered air to enter the flask, to

abolish the negative pressure.

7. Detach the rubber tubing from the lateral branch of the flask, flame

the end of the branch in the Bunsen, and plug its orifice with sterile

cotton-wool.

8. Remove the filter candle from the mouth of the flask, flame the

mouth, and plug the neck with sterile cotton-wool.

9. Disinfect the filter candle and separatory funnel by boiling.

If it is found necessary to employ pressure in addition to or in place

of suction, insert a perforated rubber stopper into the mouth of the

separatory funnel and secure in position with copper wire; next fit a

piece of glass tubing through the stopper, and connect the external

orifice with an air-pressure pump of some kind (an ordinary foot pump

such as is employed for inflating bicycle tyres is one of the most

generally useful, for this purpose) or with a cylinder of compressed air

or other gas.

In order to filter a large bulk of fluid very rapidly it is necessary to

use a higher pressure than glass would stand, and in these cases the

metal receptacle designed by Pakes (Fig. 38, a), to hold the filter

candle itself as well as the fluid to be filtered, should be employed.

(A vacuum must also be maintained in the filter flask, by means of an

exhaust pump, during the entire process.)

This piece of apparatus consists of a brass cylinder, capacity 2500

c.c., with two shoulders; and an opening in the neck at each end,

provided with screw threads.

A nut carrying a pressure gauge fits into the top screw; and into the

bottom is fitted a brass cylinder carrying the filter candle and

prolonged downwards into a delivery tube. Leakage is prevented by means

of rubber washers.

Into the top shoulder a tube is inserted, bent at right angles and

provided with a tap. All the brass-work is tinned inside (Fig. 38, a).

In use the reservoir is generally mounted on a tripod stand.

~To Sterilise.~--

1. Insert the filter candle into its cylinder and screw this loosely on.

[Illustration: FIG. 38.--Pakes' filtering reservoir--pressure and

aspiration.]

2. Wrap a layer of cotton-wool around the delivery tube and fasten in

position.

The elements of bacteriological technique · 第 2 / 33 段