CHAPTER IV

TESTING AND MATURING SELENIUM CELLS

=The Fritts Cell=, as mentioned by the inventor, when first made

has one of two states or conditions. In one the resistance is very

high, in the other very low, being but a few ohms or a fraction of an

ohm. In the latter state it is insensitive and possesses no definite

characteristic until matured. This maturing will come about gradually

if the cell is used in experimenting but can be greatly hastened by the

proper treatment. By subjecting them to an alternating or pulsating

current the resistance can be increased rapidly.

To facilitate the maturing and enable the resistance of the cell to be

determined at various stages of the treatment the maturing and testing

set shown in Fig. 12 can be made use of. The apparatus allows of the

measurement of the cell by the Wheatstone bridge and substitution

methods both with the cell lighted and dark and permits the application

of alternating current as desired. It consists of a base on which

is conveniently mounted a closed lamp box to light the cell when

necessary and the various switches and binding posts arranged for quick

manipulation of the circuit.

[Illustration: FIG. 12. TESTING AND MATURING SET]

The details of the device are given in Fig. 13. The base measuring 20

by 12 inches has mounted at the rear center a wooden box containing a

75 Watt, type C, Mazda lamp. Where lighting current cannot be obtained

a 12 volt automobile headlight bulb may be used to illuminate the cell.

The lamp in either case is connected to the switch mounted just to the

left of the box.

The front of the lamp housing has a hole measuring 1 by ¾ inches cut in

it on a level with the lamp filament. Two clips cut from spring brass

of the shape shown in the detail drawing are mounted on the front of

the box in such a position that when the posts on the back of the cell

are slipped into the holes in the ends of the strips the window of the

cell will be opposite the opening in the lamp housing. Connection is

made to the cell by means of these clips.

[Illustration: FIG. 13. LAYOUT AND WIRING DIAGRAM OF TESTING AND

MATURING SET]

At the extreme left of the base a double pole fuse switch is mounted

to control the alternating current to treat the cell. Instead of fuses

two tubular incandescent lamps are screwed into the receptacles on the

switch to limit the A. C. to a value that will not endanger the cell

by overheating it. Should lighting current not be available use can be

made of a buzzer and telephone induction coil connected to a dry cell

as shown in Fig. 14 to furnish current for treating the cell.

[Illustration: FIG. 14. CONNECTIONS FOR BUZZER AND INDUCTION COIL TO

PRODUCE ALTERNATING CURRENT]

A small two point battery switch and four double spring binding posts

are also mounted on the base and wired as shown by the dotted lines.

A fairly sensitive galvonometer is employed to indicate when the

bridge is balance. A telephone receiver might be used for the purpose,

opening and closing the circuit to cause clicking in the receiver,

the bridge being balance when the noise is reduced to a minimum. The

small center zero ammeters with the shunt removed make excellent

galvonometers.

Ratio arms and a rheostat box having a maximum resistance of 100,000

ohms complete the apparatus necessary to make the tests on the cells.

A laboratory set with this range is rather expensive and since our

measurements need not be extremely accurate a good resistance box may

be made from resistance units as used for motor starting and signal

work. These units consist of an iron tube covered with asbestos on

which is wrapped the resistance wire, the wire in turn being covered

with a vitreous insulating material baked in place. These units can

be purchased quite reasonable from any large electrical supply house

in any resistance up to 150,000 ohms. For our purpose 15 units will

be required, five, 200 ohm; five, 2000 ohm and five, 20,000 ohm; all

tapped at the center, for the rheostat arm. For the ratio arms a

single 1000 ohm unit tapped at the center is used. The rheostat arm

units should be mounted in a box and heavy leads run to 12 single

pole switches mounted on the top of the box. The method of wiring

the resistances is shown in Fig. 15, the switches being marked so

the resistance in the circuit can be quickly determined. With this

arrangement any resistance from 100 to 111,000 ohms can be obtained in

steps of 100 ohms by opening the proper switches.

[Illustration: FIG. 15. CONNECTIONS FOR INTERIOR OF RHEOSTAT BOX]

The ratio arms are made by bringing leads from the ends and center

of the 1000 ohm unit. Ratios other than one to one are not advised,

for the cells are so sensitive to external influences that one system

of measurement must be adopted and adhered to if the cells are to be

compared. With the one to one ratio half the current flows thru the

cells when the bridge is balanced.

The current for testing the cells can be obtained from a dozen three

cell flashlight batteries. The battery should be connected to a

multipoint switch so that any number of cells can be switched into the

current as desired.

To prepare the various instruments for testing the cells with the

bridge circuit connect as shown in Fig. 16. The diagrammatic wiring

is shown in the insert in the illustration. The positive or carbon of

the battery is connected to post A. The source of alternating current

whether from the lightning mains or an induction coil is connected to

the double pole switch, current for the lamp in the enclosed box being

supplied to it thru the single pole switch.

[Illustration: FIG. 16. CIRCUIT FOR WHEATSTONE BRIDGE MEASUREMENT]

To test the cell, open both knife switches and place switch S on

the left hand point. Place the cell in the clips with the terminal

connected to the gold leaf in the clip connected to binding post

A. This makes the gold leaf the anode of the cell. Now close the

battery switch applying about 6 volts to the bridge. Balance the

bridge by adding or removing resistance in the rheostat arm until the

galvonometer gives no deflection. The resistance of the cell in the

dark is read direct from the markings on the open switches on the

rheostat box.

Now close the single pole knife switch lighting the cell and again

balance the bridge. The latter reading will be the light resistance of

the cell, gold anode.

For convenience in recording the data a sheet of paper should be ruled

into columns headed, date, voltage applied, resistance dark, resistance

lighted (gold anode), resistance dark, resistance lighted (copper

anode) and remarks. The cells should be numbered and the corresponding

data sheet headed with the same number so that changes in the cell can

readily be detected and improvements noted. A separate sheet should be

provided for each cell.

Now increase the voltage to 9 volts and take another set of readings

with the cell both dark and lighted. The values obtained are recorded

and the voltage increased further. The cell is tested with gradually

increasing voltages till the maximum voltage possible without heating

the cell has been applied. Heating of the cell can usually be noted by

a faint crackling noise being given but it is advisable to feel the

surface of the mica occasionally to detect any heating.

It may be found on examining the data obtained that the resistance of

the cell has varied with different voltages. We can classify the cells

by calling a cell in which the resistance increases with an increasing

voltage the A type, those in which the resistance falls off with an

increase of voltage the B type and those in which changes of voltage

cause little or no change of resistance the C type.

Now reverse the cell in the clips making the copper plate the anode and

repeat the above series of tests and record the values in the proper

columns on the ruled sheet. It will be found in many cases that the

reversal of the current thru the cell has increased the resistance. A

cell showing this characteristic is polarized while one in which the

reversal of the current does not alter the resistance to any great

extent is non-polarized.

The cell is now to be treated with alternating current for a period of

five minutes by opening the battery switch, cutting the galvanometer

out of the circuit and closing the double pole switch. Current will

flow thru the ratio arms and the cell. Care should be taken that the

current is not heavy enough to heat the cell excessively. If this

occurs reduce the current by adding resistance till heating is not

detected.

The cell is again tested according to the directions already given

both for its light and dark resistances with the current flowing in

both directions thru the cell. If the difference between the dark and

light resistance has increased it is safe to say that the cell will be

sensitive to light and the treatment should be continued to develop

this property. The quickest method of doing this is to select from the

various readings the voltage that gives the greatest difference in the

dark and light resistance. Use this voltage to make one test after each

treatment with A. C. till the sensitiveness of the cell to light has

reached a fair value. When the resistance in the dark is ten times as

great as in the light the cell is suitable for experimental working and

treatment can be discontinued.

Should the cell have practically no resistance when first put in the

testing set it is useless to go thru the entire series of tests till

the resistance has been raised. Treat the cell with A. C. repeatedly

till the resistance is brought up to a fair amount, at least 500 ohms,

then make the tests outlined previously.

Sometimes even prolonged treatment will fail to raise the resistance,

in this case test the cell for polarization by reversing in the clips.

If strongly polarized the cell may be a good generator, i.e., will

give a current under the influence of light. To test this, connect the

galvonometer to posts A and D of the set, put battery switch on left

hand point and light the cell by closing the single pole knife switch.

If the galvonometer gives a deflection it indicates that current is

being generated in the cell. This cell should be reserved for use as

a generator, this property being increased by short circuiting the

terminals and exposing the cell to light periodically until it will

generate a fair amount of current. The current generated by these cells

is a true photo-electric current, no chemical action taking place, the

light rays being converted directly into electricity by some unknown

action of the cell. The current flows from the copper plate thru the

external circuit back to the gold foil terminal.

Should the cell after prolonged treatment with A.C., fail to increase

in resistance or having increased in resistance and remain insensitive

to light and not prove to be a current generator the cell must be

classed as useless. It is seldom indeed that this occurs for a cell

that shows even a slight change in resistance when lighted should be

treated with A.C. from time to time and used in experiments and will

eventually increase in sensitiveness sufficiently to be of value. When

a cell proves intractable, the gold foil may be carefully removed by

means of a stiff brush and the cell put back in the hot press to be

reconstructed. Retreating with heat and pressure will often give a very

sensitive cell.

Even when the cells are being used for experimental work the

maturing process will be going on. The point of maturity and maximum

sensitiveness of any cell has been reached when the dark resistance of

the cell remains constant over a period of time. The maturing seems to

affect the cell by increasing the dark resistance, the light resistance

remaining practically the same thruout. From this it will be seen that

a cell with a very low resistance when first made may under proper

treatment become extremely sensitive to light.

As previously mentioned the testing set may be used for measuring the

resistance of the cells by the substitution method. The apparatus is

connected as shown in Fig. 17 when so used, a diagrammatic circuit

being given in the insert. When the battery switch is on the left hand

point the cell is in series with the battery and galvonometer. When

the switch is moved to the right hand point the rheostat is in series

with the battery and galvonometer. The method of measuring is to first

determine the galvonometer deflection with the cell in the circuit and

then by switching the rheostat into the circuit and adjusting it so

the galvonometer gives the same deflection enabling the resistance of

the cell to be read directly. The same series of tests should be gone

through with this method as with the bridge circuit.

[Illustration: FIG. 17. CIRCUIT FOR SUBSTITUTION METHOD OF MEASUREMENT]

The substitution method has the advantage of indicating roughly

the sensitiveness of the cell to light. With the cell darkened and

the current flowing thru it the galvonometer will give a certain

deflection, on lighting the cell the deflection will increase

indicating a lowering of the resistance. The determination of cell

sensitiveness is more rapid and this circuit can be employed when the

cell has a low resistance at first and it is necessary to increase it

before tests can be made. With the substitution method of measurement

it is advisable to use a rather insensitive galvonometer or meter since

the current at times may reach a value that would damage a delicate

instrument. A tangent galvonometer with heavy windings will be found

most suitable.

To determine if a cell is sensitive enough to close a relay the

substitution circuit may be used with a relay connected in place of the

galvonometer. If the cell is suitable for the purpose the relay will

close when the cell is lighted.

[Illustration: FIG. 18. SHOWING CELL READY FOR ASSEMBLY WITH FOUR

COMPLETED CELLS IN BACKGROUND]

For practical purposes the sensitiveness of a cell to light and its

current generating properties are the only ones of value but other

properties of these cells will be mentioned later. These may be

developed by proper treatment and the results of experiments along

these lines can hardly be foreseen with any degree of accuracy at the

present stage of the development of the cells.

When satisfied that a cell is properly made and fairly sensitive it can

be permanently sealed by pouring melted sealing wax around the edges

and smoothing with a hot knife. A small sheet of paper should be pasted

on the back of the cell with the more important characteristics marked

thereon as well as the most suitable voltage. The terminal connected to

the gold foil can be indicated by a positive (+) sign for convenience

in properly connecting the cell into the circuit.