The difference of the readings is then proportional to

(v1 - v2)(v2 - v3).

But this last expression is proportional to the instantaneous power

taken up in the inductive circuit, and hence the difference of the two

readings of the electrometer is proportional to the mean power taken

up in the circuit (_Phil. Mag._, 1891, 32, p. 206). Ayrton and Perry

and also P.R. Blondlot and P. Curie afterwards suggested that a single

electrometer could be constructed with two pairs of quadrants and a

duplicate needle on one stem, so as to make two readings

simultaneously and produce a deflection proportional at once to the

power being taken up in the inductive circuit.

[Illustration: FIG. 7.--Quadrant Electrometer. Dolezalek Pattern.]

Quadrant electrometers have also been designed especially for measuring

extremely small potential differences. An instrument of this kind has

been constructed by Dr. F. Dolezalek (fig. 7). The needle and quadrants

are of small size, and the electrostatic capacity is correspondingly

small. The quadrants are mounted on pillars of amber which afford a very

high insulation. The needle, a piece of paddle-shaped paper thinly

coated with silver foil, is suspended by a quartz fibre, its extreme

lightness making it possible to use a very feeble controlling force

without rendering the period of oscillation unduly great. The resistance

offered by the air to a needle of such light construction suffices to

render the motion nearly dead-beat. Throughout a wide range the

deflections are proportional to the potential difference producing them.

The needle is charged to a potential of 50 to 200 volts by means of a

dry pile or voltaic battery, or from a lighting circuit. To facilitate

the communication of the charge to the needle, the quartz fibre and its

attachments are rendered conductive by a thin film of solution of

hygroscopic salt such as calcium chloride. The lightness of the needle

enables the instrument to be moved without fear of damaging the

suspension. The upper end of the quartz fibre is rotated by a torsion

head, and a metal cover serves to screen the instrument from stray

electrostatic fields. With a quartz fibre 0.009 mm. thick and 60 mm.

long, the needle being charged to 110 volts, the period and swing of the

needle was 18 seconds. With the scale at a distance of two metres, a

deflection of 130 mm. was produced by an electromotive force of 0.1

volt. By using a quartz fibre of about half the above diameter the

sensitiveness was much increased. An instrument of this form is valuable

in measuring small alternating currents by the fall of potential

produced down a known resistance. In the same way it may be employed to

measure high potentials by measuring the fall of potential down a

fraction of a known non-inductive resistance. In this last case,

however, the capacity of the electrometer used must be small, otherwise

an error is introduced.[4]

See, in addition to references already given, A. Gray, _Absolute

Measurements in Electricity and Magnetism_ (London, 1888), vol. i. p.

254; A. Winkelmann, _Handbuch der Physik_ (Breslau, 1905), pp. 58-70,

which contains a large number of references to original papers on

electrometers. (J. A. F.)

Encyclopaedia Britannica, 11th Edition, "Ehud" to "Electroscope" Volume 9, Slice 2 · 第 41 / 43 题