| R p | | E | | | | |
| e o e | Horse- | f |Amount |Quantity| Cubic | |
Compressors. | v f r | Power | f |of Air | of Air |Feet of |Final Air|
| o |Absorbed| i |Passing| Passing|Air per |Pressure.|
| l E m | by | c |through| through| Horse- | |
| u n i |Compres-| i | Inlet | Valves | Power | |
| t g n | sors. | e | Valves| per | and per| |
| i i u | | n | each | Hour. | Hour. | |
| o n t | | c |Revolu-| | | |
| n e e | | y | tion. | | | |
| s . | | . | | | | |
--------------+-------+--------+------+-------+--------+--------+---------+
| | | | cubic | cubic | |lb. per |
1. | | | | feet | feet | |sq. in. |
_Sturgeon_ | | | | | | | |
_Compressor_ | 37 | 302 | .87 | 41.67 | 91,507| 261.3 | 90 |
Diameter of | 37 | 258 | .87 | 38.13 | 84,650| 276.1 | 90 |
cylinder, | | | | | | | |
23.62 in. | | | | | | | |
and 21.66 in.;| | | | | | | |
stroke, | | | | | | | |
48.63 in. | | | | | | | |
| | | | | | | |
2. | | | | | | | |
_Cockerill_ | 40 | 337 | .83 | 46.61 | 111,864| 281.83 | 90 |
_Compressor._ | 45 | 353 | .83 | 46.61 | 125,844| 302.66 | 90 |
Diameter of | 40 | 342 | .88 | 49.43 | 118,632| 296.65 | 90 |
cylinder, | 46 | 377 | .85 | 48.02 | 132,534| 298.77 | 90 |
25.98 in.; | 38.67 | 324 | .89 | 50.14 | 116,434| 306.19 | 90 |
stroke, | 38.5 | 337 | .89 | 50.14 | 115,818| 294.18 | 90 |
47.24 in. | 38.6 | 329 | .91 | 50.84 | 117,740| 305.13 | 90 |
| | | | | | | |
| | | | | | | |
3. | | | | | | | |
_Riedler_ | 52 | 615 | .985 | 77.34 | 241,300| 353.50 | 90 |
_Compressor._ | 60 | 709 | .985 | 76.98 | 277,128| 353.50 | 90 |
Diameter of | 38 | 422 | .985 | 77.34 | 176,330| 376.12 | 90 |
low-pressure | 39 | 424 | .985 | 77.34 | 181,030| 384.60 | 90 |
cylinder, | | | | | | | |
42.91 in.; | | | | | | | |
diameter of | | | | | | | |
high-pressure | | | | | | | |
cylinder, | | | | | | | |
26.38 in.; | | | | | | | |
stroke, | | | | | | | |
47.24 in. | | | | | | | |
--------------+-------+--------+------+-------+--------+--------+---------+
The results thus obtained were so satisfactory that the designs were
prepared for the great compressors to be operated at the new central
station on the Quai de la Gare by the 2,000 horse power engines.
The transmission of the compressed air through the mains is
unavoidably attended with a certain percentage of loss, which, of
course, increases with the length of the transmission, the presence of
leakage at the joints, etc. Professor Riedler has devoted considerable
time to the investigation of this source of waste, and we shall
presently refer to the results he has recorded; in the first place,
however, we propose to consider what he has to say on the subject of
utilizing the air at the points of delivery, and the means employed
for obtaining a relatively high efficiency of the motor.
In the earliest stages of the Popp system in Paris it was recognized
that no good results could be obtained if the air were allowed to
expand direct into the motor; not only did the formation of ice due to
the expansion of the air rapidly accumulate and choke the exhaust, but
the percentage of useful work obtained, compared with that put into
the air at the central station, was so small as to render commercial
results hopeless. The practice of heating the air before admitting it
to the motor is quite old, but until a few years ago it never seems to
have been properly carried out; in several mining installations where
this motive power had been long used, more or less imperfect attempts
had been made to heat the air; in one instance only, recorded by
Professor Riedler, was an efficient means employed. In this case a
spray of boiling water was injected into the cylinder and mixed with
the air at each stroke, with the result that a very marked economy was
obtained.
After a number of experiments, Mr. Popp arrived at the conclusion that
the simplest mode of heating, if not the most efficient, was at all
events the most suitable, as it was a matter of the first importance
that subscribers should not be troubled with the charge of any
apparatus involving complication or careful management; he therefore
adopted a simple form of cast iron stove lined with fireclay, heated
either by a gas jet or by a small coke fire. It was found that this
apparatus, crude as it was, answered the desired purpose, until some
better arrangement was perfected, and the type was accordingly adopted
throughout the whole system. It was quite recognized that this method
still left much to be desired, and the economy resulting from the use
of an improved form was very marked.
From a large number of trials very carefully carried out by Professor
Gutermuth, it was found that more than 70 per cent. of the total
number of calories in the fuel employed was absorbed by the air and
transformed into useful work. Whether gas or coal be employed as the
fuel, the amount required is so small as to be scarcely worth
consideration; according to the experiments carried out, it does not
exceed 0.09 kilo. per horse power and per hour, but it is scarcely to
be expected that in regular practice this quantity is not largely
exceeded. Professor Weyrauch has also carefully investigated this part
of the subject and fully confirms, if he, indeed, does not go beyond
Professor Gutermuth. He claims that the efficiency of fuel consumed in
this way is six times greater than when burnt under a boiler to
generate steam. He goes so far as to assert that with a good method of
heating the air, not only can all the losses due to the production and
the transmission of the compressed air be made good, but also that it
will actually contain more useful energy at the motor than was
expended at the central station in compressing it.
According to Professor Riedler, from 15 to 20 per cent. above the
power at the central station can be obtained by means at the disposal
of the power users, and it has been shown by experiment that by
heating the air to 250 deg. Cent. an increased efficiency of 30 per
cent. can be obtained. Better results than those heretofore obtained
may, therefore, be confidently expected with a more perfect and
economical application of the fuel in heating the air, and a better
means of regulation in admitting it to the motors. In his report
Professor Riedler indicates a method by the use of which he considers
considerable advantages may be secured. This is the heating the air in
two stages instead of at one operation, and passing it through two
motors, to the first of which the air is admitted heated only to a
moderate extent; the exhaust from this motor then passes into a second
heater and thence into the second motor. A series of experiments with
this arrangement were recently carried out.
The consumption of air per brake horse power was reduced from 812
cubic feet per hour, a favorable duty in the single motor, to 720, and
in the best result to 646 cubic feet with the two motors and double
heaters. It should be added that these trials were carried out with
steam engines but ill adapted for the purpose. It is to be regretted
that the experiments of Professor Riedler could not have been
conducted with more perfect appliances, but it must be borne in mind
that the utilization of compressed air, especially as regards the
motors, is still in a very imperfect stage, and that a great deal
remains to be done before the maximum power available at the motor can
be obtained. Investigations in this direction for a considerable time
to come must be directed, therefore, toward improving the design and
construction of the motors and the treatment of the air at the point
of delivery into the engine.
A large number of motors in use among the subscribers to the
Compressed Air Company, of Paris, are rotary engines developing one
horse power and less, and these in the early times of the industry
were extravagant in their consumption, to a very high degree. To some
extent this condition of things has been improved, chiefly by the
addition of better regulating valves to control the air admission.
As altered, the two horse power rotary motors, when employed as cold
air engines, a method often desired in special industries, consume
1,059 cubic feet per hour and per indicated horse power; with a
moderate degree of heating, say to 50 deg. Cent., this consumption
falls to 847 cubic feet. The efficiency of this type of rotary motors
with air heated to 50 deg. may now be assumed at 43 per cent., not a
very economical result, it is true, and one that may be largely
improved, yet it is evident that with such an efficiency the use of
small motors in many industries becomes possible, while in cases where
it is necessary to have a constant supply of cold air, economy ceases
to be a matter of the first importance.
Some useful results were obtained with compressed air used in crank
engines; it is to be regretted that with this, also, apologies have to
be made for the imperfect design and construction; they were old steam
engines, some of those of two horse power losing from 25 to 30 per
cent. by their own friction; some of the others tried, however, were
far better, a newer type losing only from 8 to 10 per cent., while the
80 horse power referred to below showed an efficiency of 91 per cent.
From these trials Prof. Riedler deduces--assuming 85 per cent.
efficiency--a consumption of 611, 752, and 720 cubic feet per brake
horse power. It is very evident from the foregoing that the Compressed
Air Company, of Paris, will never do itself justice until as much
thought and care has been devoted to the economical use of the motive
power as has been expended in the means of producing it, and Professor
Riedler's recent investigations should be especially useful in this
respect. The question has indeed attracted the attention of more than
one manufacturer, and reference is made to a particular type of small
rotary motors which are being constructed by MM. Riedinger & Co., and
which is stated have given very excellent results. These engines were
specially used for working sewing machines and developed on the brake
an efficiency of 34.07 and 51.63 foot pounds per second. Trials were
made with a half horse power variable expansion Riedinger engine.
TRIALS OF A SMALL ROTARY RIEDINGER ENGINE.
______________________________________________________________
| |
Number of trials. | I. | II.
______________________________________________|_______|_______
| |
Initial air pressure. lb. per square inch | 86 | 71.8
" temperature. deg. Cent. | +12 | +170
Ft. pounds per second measured on the brake. | 51.63 | 34.07
Revolutions per minute. | 384 | 300
Consumption of air for one horse power per | |
hour. | 1,377 | 988
______________________________________________|_______|_______
TRIALS OF A 0.5 HORSE POWER RIEDINGER ROTARY ENGINE.
_____________________________________________________________________
| | | |
Number of trials. | I. | II. | III. | IV.
__________________________________________|______|______|______|_____
| | | |
Initial pressure of air. lb. per sq. in. | 54 | 69.7 | 85 | 71.8
" temperature of air. deg. Cent. | 170 | 180 | 198 | 8
Final " " " | 25 | 20 | ... | 25
Revolutions per minute. | 335 | 350 | 310 | 243
Foot pounds per second measured on | | | |
brake. | 271 | 477 | 376 | 316
Consumption of air per horse power | | | |
and per hour. | 883 | 791 | 900 |1,148
__________________________________________|______|______|______|______
TRIAL OF AN 80 HORSE POWER (NOMINAL) FARCOT STEAM ENGINE.
___________________________________________________________________
| R p | | |
| e e | I | | Consumption of
| v r | n | Temperature | air per horse
| o | d h p| of air. | power and per
| l m | i o o| | hour.
| u i | c r w|__________________|________________
| t n | a s e| | | |
Motor. | i u | t e r|Admission|Exhaust.|Nominal| Brake
| o t | e .| | | horse | horse
| n e | d | | | power.| power.
_________________|_s_.__|______|_________|________|_______|________
| | | deg. C | deg. C | |
Nominal 80 horse | 54.3 | 72.3 | 129 | 21 | 469 | 517
power single | 54.3 | 72.3 | 152 | 29 | 437 | 475
cylinder Farcot | 54.0 | 72.3 | 160 | 35 | 424 | 465
engine. | 40 | 65.0 | 170 | 49 | 438 | 477
_________________|______|______|_________|________|_______|________
These motors, it may be assumed, represent the best practice that has
been obtained up to the present time in the construction of compressed
air motors; with the smallest of them, indicating about one-tenth of a
horse power, the consumption of air, when admitted cold, was 1377
cubic feet and 988 cubic feet when the air was heated before
admission. The half horse power engine consumed 1148 cubic feet of
cold air, and of heated air 791 cubic feet per horse power and per
hour. It should be mentioned that these, the most valuable and
suggestive of all the trials carried out by Professor Riedler, were
conducted with the greatest care, two distinct modes of measuring the
air supplied being followed on two occasions for each test; it may
therefore be considered that the results given are absolutely correct.
The trials were made with an old single cylinder Farcot engine,
nominally of 80 horse power, but indicating over 72.3. With this
engine the consumption of air varied from 465 to 517 cubic feet, the
larger consumption being due to the lower temperature (129 deg. Cent.)
to which the air was raised before admission; in the most economical
result the temperature was 160 deg. Cent. The volumes of air referred
to are, of course, in all cases taken at atmospheric pressure.
Among the important losses that have to be reckoned with in every
system of distributing motive power from a central station--whether by
steam or by electricity, water, or compressed air--losses must occur
in the mains by which the power generated is transferred from the
point of production to that of consumption. In the case we are now
considering very careful tests were conducted in 1889 by Professor
Kennedy, to whose report we have already referred. Since that time
important changes have been made by the Compressed Air Company, at
Paris, in the details of distribution, and on this account the later
investigations of Professor Riedler on the losses due to this cause
are of special interest.
Before its admission into the mains a certain loss occurs at the St.
Fargeau station, in the large reservoirs to which the air is delivered
from the compressors. This question of preliminary storage was one
that received considerable attention when the designs of the new
station on the Quai de la Gare were being considered. It was intended
to construct very large receivers in the basement of the station, and
the foundations for these were even commenced. It was decided,
however, that for the 10,000 horse power which is to form the first
section of the new station, and for which the complete system of mains
has already been laid down, storage reservoirs would be unnecessary,
and a saving both in first cost and subsequent loss of air would be
effected. The length of mains of 19.69 in. diameter is so considerable
that they will contain at all times a sufficient reserve of air to
prevent any irregularities in pressure at the motors.
With reference to these mains it may be mentioned that, unlike the
11.81 in. conductors of the St. Fargeau system, of which 17 kilometers
are laid in the Paris subways, the new mains are entirely laid in the
streets, it having been found impossible to make room for these large
pipes in the subways already crowded with telegraph and telephone
wires, water mains, etc.
Professor Riedler investigated the two causes of loss in the
mains--leakage and resistance. It was superficially evident that the
mains of the old system were so well laid, and the joints so well
designed, that the loss from leakage was never a serious one. In
order, however, to ascertain the amount accurately, a series of
careful experiments were carried out by Professor Gutermuth with the
11.81 in. mains of the St. Fargeau system.