TABLE I

=====+===========================================================+====+======+======

| | |Effec-|

| Height of Chimneys and Commercial Horsepower Capacity |Side| tive |Actual

Diam-+---+---+---+-----+-----+-----+-----+-----+-----+-----+-----+ of | Area | Area

eter |50 |60 |70 | 80 | 90 | 100 | 110 | 125 | 150 | 175 | 200 | Sq.|Square|Square

In. |Ft.|Ft.|Ft.| Ft. | Ft. | Ft. | Ft. | Ft. | Ft. | Ft. | Ft. | In.| Ft. | Ft.

-----+---+---+---+-----+-----+-----+-----+-----+-----+-----+-----+----+------+------

18 | 23| 25| 27| | | | | | | | | 16| .97| 1.77

21 | 35| 38| 41| | | | | | | | | 19| 1.47| 2.41

24 | 49| 54| 58| 62| | | | | | | | 22| 2.08| 3.14

27 | 65| 72| 78| 83| 87| | | | | | | 24| 2.78| 3.98

30 | 84| 92|100| 107| 113| 119| | | | | | 27| 3.58| 4.91

33 |105|115|125| 133| 141| 149| | | | | | 30| 4.48| 5.94

36 |128|141|152| 163| 173| 182| 191| | | | | 32| 5.47| 7.07

39 |154|168|183| 196| 208| 219| 229| | | | | 35| 6.57| 8.30

42 |182|200|216| 231| 245| 258| 271| 288| | | | 38| 7.76| 9.62

48 | |269|290| 311| 330| 348| 365| 389| | | | 43| 10.44| 12.57

54 | |348|376| 402| 427| 449| 472| 503| 551| | | 48| 13.51| 15.90

60 | |436|471| 503| 536| 565| 593| 632| 692| 748| | 54| 16.98| 19.64

66 | | |579| 620| 658| 694| 728| 776| 849| 918| 981| 59| 20.83| 23.76

72 | | |698| 746| 792| 835| 876| 934|1,023|1,105|1,181| 64| 25.08| 28.27

78 | | | | 885| 949| 990|1,038|1,107|1,212|1,310|1,400| 70| 29.73| 33.18

84 | | | |1,035|1,098|1,157|1,214|1,294|1,418|1,531|1,637| 75| 34.76| 38.48

90 | | | | |1,269|1,338|1,403|1,496|1,639|1,770|1,893| 80| 40.19| 44.18

96 | | | | | |1,532|1,606|1,712|1,876|2,027|2,167| 86| 46.01| 50.27

100 | | | | | | |1,760|1,865|2,043|2,197|2,359| 89| 50.11| 54.54

104 | | | | | | |1,899|2,024|2,218|2,395|2,560| 93| 54.39| 59.00

108 | | | | | | |2,051|2,190|2,399|2,591|2,770| 96| 58.83| 63.62

112 | | | | | | | |2,323|2,588|2,795|2,983| 100| 63.46| 68.42

118 | | | | | | | |2,632|2,883|3,114|3,339| 105| 70.71| 75.94

120 | | | | | | | |2,725|2,986|3,225|3,447| 107| 73.22| 78.54

124 | | | | | | | |2,915|3,193|3,449|3,687| 110| 78.31| 83.86

130 | | | | | | | |3,165|3,467|3,745|4,004| 116| 85.04| 90.76

136 | | | | | | | | |3,868|4,178|4,466| 121| 94.85|100.88

142 | | | | | | | | |4,305|4,567|4,886| 126|103.69|109.98

150 | | | | | | | | |4,719|5,097|5,448| 133|115.72|122.72

=====+===+===+===+=====+=====+=====+=====+=====+=====+=====+=====+====+======+======

Considering the first requirement, a circular flue is considered more

efficient than a square one, because its inside surface offers less

resistance to the passage of the gases, and there is not the likelihood

of eddies being formed. There is much difference of opinion among

engineers as to whether a stack should be narrower toward the top or

increased in size. The practice is to taper a stack toward the top,

this being done more on account of the necessity for increasing its

stability than because of the draft. Some stacks have been built,

however, with a larger inside diameter at the top than at the bottom,

with the idea of providing a greater sectional area for the passage of

the gases as their velocity is decreased. The capacity of the stack

for carrying off the products of combustion depends on the temperature

of the inside gases as compared with the temperature of the outside

air. The average temperature in stacks for power purposes ranges from

450° to 600° F., and, therefore, as there is little difference in the

travel of gases in flues between these temperatures, Table I can safely

be used in determining the diameter and height of stack for a given

capacity of power plant.

In Table I, it will be observed that the capacity of the stack is given

in horsepower, and in calculating this table it was considered that

5 pounds of coal were burned to develop 1 horsepower, this being a

high figure with the present economical systems of power generation.

Allowance has also been made, in this table, for the friction of the

gases against the side walls of the stack, it being considered that a

2-inch layer of dead air exists between the stack lining and the gases.

[Illustration: FIG. 31]

=65. Stability of Brick Chimneys.=—In considering the stability of

brick stacks, the overturning moment due to the wind must not exceed

the resisting moment of the stack to overturning about the base. For

instance, referring to Fig. 31, the pressure _p_ due to the wind acts

with the lever arm _x_ about the base of the stack, tending to overturn

it. The stack, or chimney, resists this overturning moment with its

weight _w_, acting through a lever arm _y_; if these two moments

are equal, the stack can be considered safe under the conditions

considered, though it is better to have some factor of safety, 2

usually being sufficient. An easy formula by which to determine whether

a stack is stable or not, is as follows:

_h_² × _dc_

_w_ = ------------

b

in which _w_ = weight of stack, in pounds;

_h_ = height of stack, in feet;

_d_ = mean diameter of stack, in feet;

_c_ = constant;

_b_ = width of base.

The constant _c_ varies with the shape of the stack. For a square

stack, when the wind is blowing at hurricane violence, 56 is used; for

an octagonal stack, 35; and for a round stack, 28.

To demonstrate this formula, consider a square chimney having an

average breadth of 8 feet and a width at base of 10 feet, the stack

being 100 feet high. The problem is, therefore, to find what the weight

of the stack must be in order to resist the greatest wind pressure

likely to occur. By substitution, in the formula,

100 × 100 × 8 × 56

_w_ = ------------------ = 448,000 pounds

10

With brickwork weighing about 120 pounds per cubic foot, the chimney in

question must therefore have an average thickness of somewhat more than

13 inches.

[Illustration: FIG. 32]

=66.= A good rule to follow in designing brick stacks is to make

the base at least one-tenth of the height. For stacks under 5 feet

in diameter, the walls for the first 25 feet from the top may be 8

inches, increased 4½ inches for each additional 25 feet from the top.

If the stack is more than 5 feet in diameter, the thickness at the top

should be 1½ bricks, or 12 inches, with a 4½-inch increase for each

25 feet. If the stack is less than 3 feet in diameter, the brickwork

for the first 10 feet from the top may be as little as 4½ inches; this

thickness, however, is not recommended, as the weather is likely to

penetrate such a thin wall, and sooner or later, together with the

exposure to the gases, destroy the brickwork.

=67. Construction of Brick Chimneys.=—All brick stacks must be provided

with a cast-iron or stone coping at the top, and it is usually well

to tie them in toward the base with good heavy stone band courses.

In constructing brick stacks, the brickwork should be laid up in

lime-and-cement mortar, and the bricks well covered and slid in place,

not just tapped or hit with the handle of a trowel.

All chimneys should also be provided, for a distance of at least

one-third of their height from the base, with a fire-brick lining, laid

up in fireclay, and at the bottom of this lining, where the flues from

the boiler enter the stack, cast-iron cleaning doors and frame should

be provided for removing soot that will accumulate and drop down. A

good example of a brick stack is given in Fig. 32; this stack has a

capacity of 500 horsepower, and is sufficiently stable to resist any

wind pressure.