52. TEST OF INTERNAL LEAKAGE OR SLIP.

_a._ Set safety-valves at 115 lbs., shut all water outlets, admit steam

enough to give 100 pounds water pressure, then pump will move very

slowly under the influence of the leakage past plungers. About one

revolution of pump per minute shows a proper accuracy of fit. Anywhere

from 1/3 to 2 revolutions per minute is satisfactory.

_Too tight a fit is bad_, as if not exceedingly uniform it induces

scoring or cutting of the metals. Moreover, should the pump happen

to be run dry for a few minutes before catching its suction a slight

warming and expansion of the plunger may cause it to stick and cut.