RUBBER CHECK VALVES.

_f._ Four rubber check valves, one for each pulsation chamber, and

similar to ordinary pump valves, must be provided. The chambers for

these should preferably be made as a part of the pump cylinder, thus

securing a compact arrangement.

Figure 12 shows this arrangement in outline.

_g._ The valve seat should have three ribs to the central hub,

supporting the rubber valve. The net port area through the valve should

be not less than 1-1/2 square inches.

This valve seat should rest in an inverted position, and can be so

fitted up as to be readily removed. The valve stems can be of the

removable type screwing into the seat, but must be made long enough

to receive a check nut on the opposite side of seat. This will

effectually lock the stem in place.

_h._ Care must be taken to arrange the water passages through and about

these priming checks, so as to avoid all air pockets and so as to

reduce to a minimum the possibility of the valves becoming choked up by

refuse.

_i._ The valve seats, stems and all parts must be of composition and of

strong rugged design, so fitted up that there is the least chance for

the rubber valves to stick, and with all parts securely put together

the valves must be readily accessible.

_j._ The valve springs must have only sufficient strength to keep the

valves on their seats, so that they will freely open even with the low

head of priming water often existing.

[Illustration: FIG. 17.]

_k._ There must be provided, and attached to the top of each plunger

chamber, a brass check valve and air cock with umbrella top, as shown

in Fig. 17. This cock and valve must have a clear passageway through

them—the full equivalent of a 1/2-inch bore.

The check valve is to permit the outflow of air, but to prevent the

influx when the plunger is sucking. Cocks with lever handles are

used, as these show clearly whether they are open or shut.

_l._ There must also be provided a 2-inch brass gate valve for the

general control of the water to the four-check valves. The hand wheel

of this valve must be marked as per Fig. 15. The lettering must be very

clear, open, and distinct, not liable to be obscured by grease, and of

a permanent character.

It is essential for a properly working pump that the main 2-inch

priming-valve should be closed as soon as the pump is primed.

Otherwise, water will be drawn from the priming tank, lessening the

lifting power of the pump through the main suction, and if this is

continued the priming tank will often be exhausted and air drawn into

the pump, interfering with its proper action. It is for this reason

that the marking on the priming valve is required.

For all average situations, either method of priming permits of

getting the pump under way in a very few minutes, but, for cases

where the suction pipe is over 300 or 400 feet in length, or

sometimes where the lift is over 18 feet, or where there is a

combination of long length and lift within these limits, so much

time is consumed in exhausting the air from the suction pipe that it

becomes desirable to supplement this method.

For such situations, a steam ejector connected to the suction pipe

near the pump is advised, and may be required in addition to the

regular priming pipes and tank. The size of the ejector should be

sufficient to exhaust the suction pipe within about three minutes.

Such ejectors will be considered as extras not included in the

ordinary pump fittings.

For cases where pump can only take its suction under a head, if

absolutely certain that the level of the suction water will never

fall below level of center of pump, these priming pipes may be

omitted, but openings for them into the pump shell must be provided

and capped or plugged.

_A foot valve on a fire-pump suction is not advised_ except in very

rare cases, as with a lift of 18 feet or a suction pipe 500 feet or

more long. A foot valve is not needed when there is a good efficient

set of priming arrangements as described above and it is commonly

found this gives a false sense of security, and that with a fire-pump

left standing several days the water will often be found to have

leaked back, so that it is no better than if no foot valve had been

used.

A foot valve must of necessity generally be located where it is

inaccessible for quick repairs, and as they grow old, foot valves

are often a source of trouble. Where a suction pipe is exposed even

slightly to frost, a foot valve is specially objectionable.

_A priming tank is provided for the purchaser_ in all cases where

there is ever to be any lift on the suction. It is generally advised

that this tank have a capacity of one-half of what the pump can throw

at full speed in a minute. This means 250 gallons for a 500-gallon

pump and 500 gallons for a 1,000-gallon pump, etc. It is the

intention to make the pump a truly “independent source” of supply,

therefore the need of a special priming tank.