39. PIPE SIZES.

_a._ Water and steam pipe connections must have standard flanges to

connect with pipes of the sizes given below.

=============+==============+===============+========+========

Size of Pump.| Diameter of | Diameter | Steam | Exhaust

Gal. Per Min.| Suction Pipe.|Discharge Pipe.| Pipe. | Pipe.

| Inches. | Inches. | |

-------------+--------------+---------------+--------+--------

500 | 8 | 6 | 3 | 4

750 | 10 | 7 or 8[C] | 3-1/2 | 4

1,000 | 12 | 8 | 4 | 5

1,500 | 14 | 10 | 5 | 6

-------------+--------------+---------------+--------+--------

[Footnote C: Eight-inch preferred, this being the more common size for

valves, fittings, and pipes.

These suction pipe sizes, although larger than common for trade pumps

of the same size, are believed to be amply justified by experience, and

exert a powerful influence toward enabling the pump to run smoothly at

high speed with water cylinders filling perfectly at each stroke. No

defect is more common than restricted suction pipes.]

_b._ A single suction entrance at the end of the pump is to be provided

unless otherwise specified by the purchaser.

Some situations render desirable side suction entrances, for

permitting drafting water from two different sources of supply. These

additional openings are to be considered as extras. Ordinarily, the

purchaser can provide for such situations by proper piping at the

single end suction entrance.

If there is to be but one suction opening on casting, this had best

be at center, for the reason that, if suction pipe ever gets to

leaking air, this air stands a better chance of being distributed

equally to the two plungers, and has less tendency to make the pump

run unevenly.

_c._ Standard flanges and standard bolt layouts as adopted by the

Master Steam Fitters, July 18, 1894, must be used on all the above pipe

connections, as per table given below.

Pumps and Hydraulics, Part 1 (of 2) · 第 238 / 357 题