34. DELIVERY VALVES.

_a._ The total lift of delivery valves must not exceed one-half inch.

This is to avoid valve slam, as explained in Art. 33.

_b._ The aggregate valve-port area should be restricted to about

two-thirds the suction-valve area.

A small restriction of water-way through the delivery valves steadies

the action of the pump and tends to prevent undue pulsations of

pressure in the delivery pipe or fire hose. Fewer delivery valves

than suction valves are, therefore, preferred, and if extra holes

in the delivery deck are cast for shop purposes these had better be

plugged than fitted with valves.

The suction valves require more generous port-circumference and

port-area than delivery valves because when a pump has to suck its

supply through a considerable height or through a long pipe there

should be the least practicable waste of the atmospheric pressure in

getting the water into the plunger chamber, or in retarding it from

following the plunger in full contact. With the water once into the

plunger chamber there is plenty of steam pressure available to force

it out through the delivery valves.